JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023080975577Floor Panel · pulledFLOOR PANEL 231DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATED FLOOR PANEL 231DF IAW SRM 53-00-50-2R-0 AND BAC DWG 143A5810-513;[02] UPDATED MEASUREMENTS TABLE;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2SDR SWAA2023080975578Floor Panel · pulledFLOOR PANEL 231GF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATED FLOOR PANEL 231GF IAW SRM 53-00-50-2R-0 AND BAC DWG 143A5810-575;[02] UPDATED MEASUREMENTS TABLE;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLESDR SWAA2023080975579Floor Panel · pulledFLOOR PANEL 231HF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATED NEW FLOOR PANEL 231HF IAW SRM 53-00-50-2R-0.;[02] ATTACHED CURE SHEET TO THIS FAULT RECORD.;[03] VERIFIED CORRECTIVE ACTION 1; 2; CURE SHEETS AND MEASUREMENTSSDR SWAA2023080975580Floor Panel · pulledFLOOR PANEL 231KF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 231KF MATERIALS IAW SRM 53-00-50-0I-1 FIG 3 TABLE 3.<BR><BR>DUE TO EXTENT OF THE DAMAGE FABRICATED NEW 231KF FLOOR PANEL FROM BMS4-23 TYPE 2 LOT#1531001-1; INSTALLED INSERTS SDR SWAA2023080975572Floor Panel · pulledFLOOR PANEL 231LF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] UPLOADED CURE SHEET AND VERIFIED COMPLETION OF PANEL 231LF FABRICATION IAW SRM 53-00-50-2R-0 AND BOEING DWG: 143A5810 ID: 0579.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2023080975582Floor Panel · pulledFLOOR PANEL 231UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATED NEW FLOOR PANEL 231UF IAW SRM 53-00-50-2R-0.;[02] ATTACHED CURE SHEET TO THIS FAULT RECORD.;[03] VERIFIED CORRECTIVE ACTION 1; 2; CURE SHEETS AND MEASUREMENTSSDR SWAA2023080975574Floor Panel · pulledFLOOR PANEL 231ZF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATED NEW FLOOR PANEL 231ZF IAW SRM 53-00-50-2R-0.;[02] ATTACHED CURE SHEET TO THIS FAULT RECORD.;[03] VERIFIED CORRECTIVE ACTION 1; 2; CURE SHEETS AND MEASUREMENTSSDR SWAA2023080975575Floor Panel · pulledFLOOR PANEL 242NF UPPER SKIN HAS PULLED STRANDS.<[01] FLOOR PANEL 242NF UPPER SKIN WITH PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL PER SRM 53-00-50-2R-0 PARA 1. A. NOTE. AND ATTACHED CURE SHEET TO THIS FAULT RECORD.;[02] JOB COMPLETE.SDR SWAA2023080975583Floor Panel · pulledFALOOR PANEL 241KF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241KF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0 PARA 1. A. NOTE AND DWG 146A5810 SHEET SDR SWAA2023080975584Floor Panel · pulledFLOOR PANEL 241NF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241NF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0 PARA 1. A. NOTE AND DWG 146A5810 SHEET 4SDR SWAA2023080975585Floor Panel · pulledFLOOR PANEL 241RF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241RF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0 PARA 1. A. NOTE AND DWG 146A5810 SHEET 4SDR SWAA2023080975586Floor Panel · pulledFLOOR PANEL 241TF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] UPLOADED CURE SHEET AND VERIFIED FABRICATION OF PANEL 241TF IAW SRM 53-00-50-2R-0 AND DWG 146A5810 SHEET 467;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2023080975576Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] UPLOADED CURE SHEET AND VERIFIED FABRICATION OF PANEL 241UF IAW SRM 53-00-50-2R-0 AND BOEING DWG:146A5810 ID:0470.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023080975587Floor Panel · pulledFLOOR PANEL 241VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] UPLOADED CURE SHEET AND VERIFIED FABRICATION OF PANEL 241VF IAW SRM 53-00-50-2R-0 PAR. 5. S. (1) (A) - (D) AND BOEING DWG: 146A5810 ID: 0469.;[02] FINAL INSPECTION. JOB COMPLETE.<BR><BR>VERIFIED MESDR SWAA2023080975588Floor Panel · pulledFLOOR PANEL 241WF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] UPLOADED CURE SHEET AND VERIFIED FABRICATION OF PANEL 241WF IAW SRM 53-00-50-2R-0 AND DWG 146A5810 SHEET 471;[02] FINAL INSPECTION. JOB COMPLETE.SDR DALA2023071005533Unknown · unknownSHIP 0667 CORROSION ON SUPPORT FITTINGS 2 EAS (SETTLEMENT OF AFT LAVATORY) STA= Y=1638 // RBL=24 AND RBL=45 AT CPAX. CORRECTIVE ACTION: SUPPORT FITTINGS WERE REPLACED PER B757-200 SRM 51-40-02. (2851400)SDR DALA2023070605450Unknown · unknownSHIP 3355 CORROSION FLOOR BEAM Y1552.5 LOCATED FR31 TO FR37 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM Y1552.5 LOC. BETWEEN FR31 TO FR37 IN PASSENGER CABIN. (2851429)SDR SWAA2023082974746Floor Panel · debondedFWD FLOOR PANEL 221BF UPPER SKIN AT AFT I/B CORNER IS DISBONDED.<[01] REPAIRED UPPER SKIN AT AFT I/B CORNER OF FWD FLOOR PANEL 221BF IAW SRM 53-00-50-2R-1.;[02] VERIFIED JOB COMPLETE.;[03] VERIFIED ALL STEPS COMPLETE.SDR SWAA2023082974743Floor Panel · pulledFWD FLOOR PANEL 231BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 231BF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 51-10-02-0G-0 PARA 9.A.1.;[02] VERIFIED. CARD COMPLSDR SWAA2023082974745Floor Panel · pulledFWD FLOOR PANEL 232BF UPPER SKIN HAS AN AREA OF PULLED STRANDS.<[01] REPAIRED AREA OF PULLED STRANDS ON UPPER SKIN OF FWD FLOOR PANEL 232BF IAW SRM 53-00-50-2R-1.;[02] VERIFIED ALL STEPS COMPLETE.;[03] VERIFIED MEASUREMENTS TABLE; JOB COMPLETE.;[04] VERIFIED ASDR SWAA2023082974751Floor Panel · pulledFLOOR PANEL 231XF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 231XF IAW SRM 53-00-50-2R-0.;[02] VERIFIED MEASUREMENTS TABLE.;[03] JOB COMPLETE.SDR SWAA2023082974748Floor Panel · pulledFLOOR PANEL 231YF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 231YF IAW SRM 53-00-50-2R-0.;[02] VERIFIED MEASUREMENTS TABLE; JOB COMPLETE.SDR SWAA2023082974749Floor Panel · pulledFLOOR PANEL 232SF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241UF WAS REPLACED WITH A NEWLY FABRICATE FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0. ATTACHED CURE SHEET TO THIS FAULT RECORD.;[02] VERIFIED MEASUREMENTS TABLE; JOB SDR SWAA2023082974750Floor Panel · pulledFLOOR PANEL 241BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241BF WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0. ATTACHED CURE SHEET TO THIS FAULT RECORD.;[02] VERIFIED MEASUREMENTS TABLE; JOBSDR SWAA2023082974752Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241UF WAS REPLACED BY A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE PER SRM 53-00-50-2R-0. ATTACHED CURE SHEET TO THIS FAULT RECORD.;[02] VERIFIED MEASUREMENTS TABLE; JOB CSDR SWAA2023082974753Floor Panel · pulledFLOOR PANEL 242PF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 242PF IAW SRM 53-00-50-2R-0 AND BOEING DWG 144A5810 ID:0103.;[02] VERIFIED MEASUREMENTS TABLE; JOB COMPLETE.SDR SWAA2023080975569Floor Panel · damagedFWD CABIN FLOOR PANEL 221BF AFT O/B CORNER (TANG) IS BROKEN<[01] FWD CABIN FLOOR PANEL 221BF WITH AFT O/B CORNER (TANG) BROKEN WAS REPAIRED PER SRM 53-00-50-2R-1. ATTACHED CURE SHEETS TO THIS FAULT RECORD.;[02] VERIFIED CORRECTIVE ACTION 1;[03] VERIFIED CORRECSDR SWAA2023080975570Floor Panel · damagedFWD CABIN FLOOR PANEL 221GF FORWARD O/B CORNER (TANG) BROKEN<[01] COMPLETED STEPS 11 AND 12.;[02] FWD CABIN FLOOR PANEL 221GF O/B CORNER (TANG) REPAIRED IAW SRM 53-00-50-2R-6;[03] VERIFIED CORRECTIVE ACTION 2;[04] VERIFIED CORRECTIVE ACTION 2SDR AALA202307177555Floor Panel · debondedAIRCRAFT IN BASE MAINTENANCE: CABIN CENTER FLOOR PANEL 242DF UPPER SURFACE DISBONDED. REPLACED FLOOR PANEL.SDR SWAA2023071275275Floor Panel · delaminatedDOT A160-46; FLOOR PANEL 241BF HAS DELAMINATION<[01] WORK ACCOMPLISHED ON NON-ROUTINE TTG8Q00M1DKDSDR SWAA2023071275283Floor Panel · delaminatedDOT A160-44; FLOOR PANEL 231ZF HAS DELAMINATION OF TOP PLYS<[01] WORK ACCOMPLISHED ON NON-ROUTINE TTG8Q00M1D0ESDR CALA2023070702185Floor Panel · corroded5100-02757 FOUND CORROSION ON AFT CARGO FLOOR PNL 140CF AT APPROXIMATELY BS 767 ON NUTPLATE STRIP REMOVED AND REPLACED ''T'' FLOOR AFT CARGO PNL 140CF AT BS767 IAW B737-800 SRM 53-00-53 2R-1. DATA WAS TRANSCIBED FROM PAPER DOC A ERSALE WO 3985 OP 33721 BY MEN SDR CALA2023070502171Floor Panel · corroded5100-02757 FOUND CORROSION ON AFT CARGO FLOOR PNL 140CF AT APPRO XIMATELY BS 767 ON NUTPLATE STRIP REMOVED AND REPLACED ''T'' FLOOR AFT CARGO PNL 140CF AT BS767 IAW B737-800 SRM 53-00-53 2R-1. DATA WAS TRANSCIBED FROM PAPER DOC A ERSALE WO 3985 OP 33721 BY MENSDR DALA2023070405360Unknown · unknownSHIP 3355 CORROSION ON FLOOR BEAM -Y1456 LOCATED FR26 TO FR37.4 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1456 LOCATED FR26 TO FR37.4 IN PASSENGER CABIN. (2846526)SDR DALA2023070305307Unknown · unknownCORROSION ON FLOOR SUPPORTS BTW STA Y=158/200 AND RBL=44, STA Y=179 AND BTW RBL=8/43, STA Y=200 AND BTW RBL=8/44. SUMMARY OF NRC 00604: CORROSION LEVEL 2. FLOOR SUPPORTS (3 EA) WERE REPLACED PER B717-200 SRM 51-40-02-0G AND 51-41-05-0G PAR 8.A. (LP #2846527)SDR SWAA2023081874216Floorboard · delaminatedCABIN FLOOR PANEL #241DF DELAMINATED.<[01] APPLIED REPAIR IN DAMAGED AREA AT PANEL #241DF AS PER B737 SRM 53-00-50-2R-1; MATERIAL USED PO#1738579 AND PO#1783720;[02] VERIFIED STEP 1; PANEL #241DF REPAIRED.SDR DALA2023070405358Unknown · unknownSHIP 3353 CORROSION FLOOR BEAM -Y953 LOCATED FR31 TO FR37 IN PASSENGER CABIN. CORRECTIVE ACTION: REMOVED AND REPLACED NEW FLOOR BEAM -Y953 AND FASTENERS LOCATED BTW FR 26/28 TO FR37.4 IN PASSENGER CABIN. (2846037)SDR CALA2023070302147Insert · damagedSUPPORT TASK: MAIN CABIN FLOOR PANEL 241ZFF HAS 2 DAMAGED INSERTS. TRANSCRIBED FROM HAECO GSO NRC# 9288662. REMOVED AND REPLACED DAMAGED INSERTS IAW B737-900ER SRM 53-00-50 -1A-1 AND SRM 53-00-50-2R-0 ON MAIN CABIN FLOOR PANEL 241ZFF. H AECO GSO MECH V901642 SDR CALA2023070302146Floor Panel · damagedSUPPORT TASK: MAIN CABIN FLOOR PANEL 232RF HAS SURFACE DAMAGE. TRANSCRIBED FROM HAECO GSO NRC# 9288656. EVALUATED PANEL 232RF P/N 144A5810-124 AND FOUND MULTIPLE AREAS OF MISSING/PEELING FIBERS IAW B737-900ER SRM 53-00-50-1A-1. REPA IRED DAMAGED AREAS IAW B73SDR CALA2023070302145Insert · damagedSUPPORT TASK: MAIN CABIN FLOOR PANEL 242ZCF HAS 2 DAMAGED INSERTS. TRANSCRIBED FROM HAECO GSO NRC# 9288649 REMOVED AND REPLACED DAMAGED INSERTS IAW B737-900ER SRM 53-00-50 -1A-1 AND SRM 53-00-50-2R-0 ON MAIN CABIN FLOOR PANEL 242ZCF. H AECO GSO MECH V901642 SDR CALA2023070302144Floor Panel · damagedSUPPORT TASK: MAIN CABIN FLOOR PANEL 241GF HAS SURFACE DAMAGE. TRANSCRIBED FROM HAECO GSO NRC# 9288660 EVALUATED PANEL 241GF P/N 146A5810-455 AND FOUND MULTIPLE AREAS OF SURFACE DAMAGE ON UPPER SURFACE IAW B737-900ER SRM 53-00-50-1 A-1. REPAIRED DAMAGED AREASSDR DALA2023070205287Unknown · unknownAIRCRAFT 3353, CORROSION SEAT TRACK -YB LOCATED FR71 TO FR73 RH SIDE AT AFT GALLEY AREA (SSI 534159-01-2). CORECTIVE ACTION: REPLACED SEAT TRACK -YB LOCATED FR71 TO FR73 RH SIDE AT AFT GALLEY AREA AS PER A330 SRM 51-72-11-911-01 AND NAT DWG 10N00242. (LP 28450SDR DALA2023070305303Unknown · unknownAFT CARGO DOOR LOWER PAN HAS CORROSION IN SEVERAL LOCATIONS. MARKED. SUMMARY SEE NRC 001-0270:5300-2016/003 00024: EDGED SEALED AFT CARGO DOOR LOWER PAN REF REPAIRED CARGO DOOR FRAME LOWER PAN REF B717-200 SRM 53-20-15-2R REPAIR 7 AFT CARGO LOWER JAMB PAN CORRSDR SWAA2023072673375Floor Panel · delaminatedFLOORBOARD PANEL 222BF (P/N 141A5810-464) DELAMINATED AT UNDERSIDE OF AFT DRAIN HOLE. FLOORBOARD PANEL 22BF (P/N 141A5810-464) DELAMINATED AT UNDERSIDE OF AFT DRAIN HOLE.<[01] INSTALLED NEW SERVICEABLE FLOORBOARD PANEL 222BF (P/N 141A5810-464) ON CARD NO. TTG8SDR SWAA2023072173834Floor Panel · corrodedDOT 114-020. CARGO COMPARTMENT PANEL #140AF HAS MULTIPLE AREAS OF CORROSION ON INBOARD AND OUTBOARD SIDES.<[01] FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. DAMAGE BEYOND 3' IN LENGTH.;[02] VERIFIED MATERIAL TO BE .071' 2024 T-3 IAW SRM 53-60-53-0I-1 <BR>ASDR SWAA2023071273757Floor Panel · delaminatedFOUND PASSENGER CABIN FLOOR PANEL 241RF WITH A DELAMINATED SPOT<[01] REPAIRED DAMAGED AREA AT CABIN FLOOR PANEL#241RF PER B737 SRM53-00-50-2R-1 MATERIAL USED RESIN 50-A PO#1799598 AND FIBER GLASS PO#1738579;[02] VERIFIED STEP 1. COMPLETESDR DALA2023070305328Unknown · unknown(LOG 2842632) FWD WET AREA BEAM SUPPORT HAS TOOL MARKS AT STA 328 RBL 18. ACCOMPLISHED REPAIR AT FLOOR BEAM STA 328 FROM LBL 1 TO RBL 63 PER B737-900 SRM 53-10-51-2R-7.SDR DALA2023070305300Unknown · unknownCORROSION ON FLOOR SUPPORT STA Y=175 BTW X=-20 AND X=-45 AT PAX CABIN W1. SUMMARY OF NRC 00309: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=175 BTW X=-20 AND X=-45 AT PAX CABIN WAS REPLACED PER B717 SRM 51-41-05-0G PAR 8 & 51-41-02-0G PAR 4. (LP #2843312)SDR CALA2023070302123Floorboard · delaminated(SUPPORT TASK) MAIN CABIN FLOORBOARD PANEL 242HF HAS DELAMINATION. TRANSCRIBED FROM HAECO GSO NR 9282485 REPAIRED MAIN CABIN FLOORBOARD PANEL 242HF IAW UAL B737-800 SRM 53-00-50-2R-0 REPAIRED MAIN CABIN FLOORBOARD PANEL 242HF IAW UAL B737-800 SRM 53-00-50-2R-0SDR CALA2023070302122Floorboard · delaminatedSUPPORT TASK MAIN CABIN FLOORBOARD PANEL 242BF HAS DELAMINATION REF HAECO GSO NR 9282483 REPAIRED DELAMINATION ON MAIN CABIN FLOORPANEL 242BF IAW B737-80 0 SRM 53-00-50-1A-1 AND SRM 53-00-50-2R-1. HAECO GSO MECH V9341 67 INSP QC357.
Back to JASC 5321