JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA202307181253Floor Panel · damagedFABRICATE FLOORBOARD PN# 145T5876-99 REF SRZ-25-005 R STA. 680-834 LBL 20. FABRICATED FLOOR BOARD REF DRAWING # 145T5876, SHEET 99 AND SRZ-25-005 REV. R.SDR FDEA202307181252Floor Panel · damagedFABRICATE FLOOR PNL PN# 145T5876-38 REF SRZ-25-005 R. PRIMARY STRUCTURE AND MAJOR REPAIR. FABRICATED FLOOR PANEL REF E.A. H-5300-T0375343.SDR SWAA2023081779388Floor Panel · frayedMAIN CABIN FLOOR PANEL 222DF UPPER SURFACE FRAYING<[01] RECEIVED MAIN CABIN FLOOR PANEL 141A5810-749 AND WILL BE INSTALLED ON T/C TTG8Q00M0AU6;[02] VERIFIED; STEP # 1SDR SWAA2023081779389Floor Panel · damagedMAIN CABIN FLOOR PANEL 221BF MISSING A PIECE<[01] RECEIVED MAIN CABIN FLOOR PANEL 141A5810-729 AND WILL BE INSTALLED ON T/C TTG8Q00M0AV4;[02] VERIFIED; STEP # 1SDR SWAA2023081779392Floor Panel · crackedMAIN CABIN FLOOR PANEL 221GF CRACKED<[01] RECEIVED MAIN CABIN FLOOR PANEL 141A5810-181 AND WILL BE INSTALLED ON T/C TTG8Q00M0AUG;[02] VERIFIED; STEP # 1SDR SWAA2023080879447Panel · crackedWING CENTER SECTION BREAK PANEL IS CRACKED IN RADIUS NEAR FASTENER BS 540; RBL 1; WL 207<[01] UPDATED PARTS AND MEASUREMENT TABLE;[02] COMPLETED STEP 1;[03] COMPLETED STEP 1 AND VERIFIED MEASURMENT TABLE;[04] REMOVED FLOOR PANEL COMMON TO WING CENTER SECTION BSDR SWAA2023082979582Floor Panel · damagedWHILE INSTALLING HI-LOK FOR FSD MOP SILL REPAIR ARCHED ON TB5060H<[01] PERFORMED VISUAL HIDDEN DAMAGE INSPECTION; NO FURTHER VISUAL DAMAGE NOTED;[02] REMOVED ANGLE P/N 141A8314-6 AT BS 269 RBL 254 WL 208 IAW SRM 51-40-02.;[07] FORM ANGLE FROM 7075-T6 0.050' CLSDR IPXA2023071641325Floor Panel · unknownFLOOR PANEL IN POS 12L AND 12R HAS DAMAGE NEAR FASTENER. LABOR ROW NOT REQUIRED.SDR DALA2023071705775Unknown · unknownCORROSION OUT OF LIMIT ON FLOOR SUPPORTS (2 EA) LH SIDE FROM STA Y=1022 TO STA Y=1053 AND X=44, AND FROM STA Y=1022 TO STA Y=1053 AND X=53.5 AT CABIN PAX. (W2) IN REF NRC 0441. SUMMARY OF NRC 00622: FLOOR SUPPORTS (2 EA) LH SIDE FROM STA Y=1022 TO STA Y=1053 ASDR AALA202307177326Floor Panel · delaminatedAIRCRAFT WAS NOT GROUNDED: AFT CARGO, FLOOR PANEL (151PE) IS DELAMINATED AND SPONGEY. REPLACED FLOOR PANEL PER AMM 53-42-14.SDR ASAA2023071344246Floor Panel · delaminatedMAIN CABIN FWD WET AREA FLOOR BOARD DELAMINATED 141A5810-286. GROUNDED - YES. EVALUATED DAMAGE AREA TO FLOOR BOARD 141A5810-286. APPLIED POTTING COMPOUND TO AREA. REMOVED AND INSTALLED X1 INSERT. APPLIED REPAIR PLYS TO FLOOR BOARD PANEL. IAW B737-800 SRM 53-00SDR ASAA2023071344245Floorboard · delaminatedMAIN CABIN FWD WET AREA FLOOR BOARD DELAMINATED 141A5810-236. GROUNDED - YES. EVALUATED DAMAGED AREAS (X6) TO FLOOR BOARD 141A5810-236. APPLIED POTTING COMPOUND TO AREAS. REMOVED AND INSTALLED X29 INSERTS. REPLACED CORE IN X3 AREAS. APPLIED REPAIR PLYS TO FLOOSDR ASAA2023071344244Floor Panel · delaminatedMAIN CABIN FWD WET AREA FLOOR BOARD DELAMINATED 141A5810-157. GROUNDED - YES. EVALUATED DAMAGED FLOOR BOARD 141A5810-157 APPLIED REPAIR PLYS TO FLOOR PANEL. IAW B737-800 SRM 53-00-50-2R-0 REPAIR GENERAL, 53-00-50-2R-2 REPAIR 2.SDR ASAA2023071344243Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-345. GROUNDED - YES. REPAIRED FLOOR PANEL IAW B737-800 SRM 53-00-50-2R-0.SDR ASAA2023071344239Floor Panel · delaminatedMAIN CABIN FWD WET AREA FLOOR BOARD DELAMINATED 141A5810-121. GROUNDED - YES. ACCOMPLISHED PERMANENT REPAIR TO MAIN CABIN FWD WET AREA FLOOR BOARD DELAMINATION IAW B737-800 SRM 53-00-50-2R-0 + 53-00-50-2R-7.SDR ASAA2023071344238Floor Panel · delaminatedMAIN CABIN FWD WET AREA FLOOR BOARD DELAMINATED 141A5810-454. GROUNDED - YES. ACCOMPLISHED PERMANENT REPAIR TO MAIN CABIN FWD WET AREA FLOOR BOARD DELAMINATION IAW B737-800 SRM 53-00-50-2R-0 + 53-00-50-2R-7.SDR ASAA2023071344237Floorboard · delaminatedMAIN CABIN FWD WET AREA FLOOR BOARD DELAMINATED 141A5810-189. GROUNDED - YES. ACCOMPLISHED PERMANENT REPAIR TO MAIN CABIN FWD WET AREA FLOOR BOARD DELAMINATION IAW B737-800 SRM 53-00-50-2R-0 + 53-00-50-2R-7.SDR ASAA2023071344236Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-136. GROUNDED - YES. REPAIRED FLOOR PANEL IAW B737-800 SRM 53-00-50-2R-0.SDR ASAA2023071344235Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-27. GROUNDED - YES. REPAIRED FLOOR PANEL IAW B737-800 SRM 53-00-50-2R-0.SDR ASAA2023071344217Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-23. GROUNDED - YES. COMPLETED PERMANENT REPAIR OF AFT GALLEY FLOOR PANEL IAW B737-800 SRM 53-00-50-2R-0 & 53-00-50-2R-7SDR ASAA2023071344216Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-30. GROUNDED - YES. COMPLETED PERMANENT REPAIR OF AFT GALLEY FLOOR PANEL IAW B737-800 SRM 53-00-50-2R-0 & 53-00-50-2R-7.SDR ASAA2023071344195Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-28. GROUNDED - YES. COMPLETED PERMANENT REPAIR OF AFT GALLEY FLOOR PANEL IAW B737-800 SRM 53-00-50-2R-0 & 53-00-50-2R-7SDR ASAA2023071344194Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-137. GROUNDED - YES. COMPLETED PERMANENT REPAIR OF AFT GALLEY FLOOR BOARD IAW B737-800 SRM 53-00-50-2R-0 & 53-00-50-2R-7SDR ASAA2023071344193Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-123. GROUNDED - YES. REPAIRED FLOOR PANEL IAW B737-800 SRM 53-00-50-2R-0.SDR ASAA2023071344192Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-267. GROUNDED - YES. REPAIRED FLOOR PANEL IAW B737-800 SRM 53-00-50.SDR ASAA2023071344191Floor Panel · delaminatedAFT GALLEY FLOOR PANEL DELAMINATED 147A5810-90. GROUNDED - YES. REPAIRED FLOOR PANEL IAW B737-800 SRM 53-00-50-2R-0.SDR CALA2023071402245Floor Panel · damagedSUPPORT TASK: MAIN CABIN FLOOR PANEL 231DF HAS SURFACE DAMAGE. TRANSCRIBED FROM HAECO GSO NRC# 9288652. EVALUATED FLOOR PANEL 231DF AND FOUND MISSING/PEELING FIBERS THR OUGHOUT UPPER SURFACE AND 1EG DELAM IAW UAL B737-900ER SRM 53-30 -50-1A-0 AND SRM 53-00-50-SDR CALA2023071402244Floor Panel · delaminatedSUPPORT TASK: MAIN CABIN FLOOR PANEL 231UF HAS SURFACE DELAMINATION. TRANSCRIBED FROM HAECO GSO NRC# 9288657. COMPLETED WET LAY UP REPAIR ON MAIN CABIN FLOOR PANEL 231UF IAW B737-900ER SRM 53-00-50-2R-0 HAECO GSO MECH V902229 INSP QC357SDR SWAA2023081577708Floor Panel · pulledCABIN FLOOR PANEL 222BF HAS PULLED THROUGH INSERTS.<[01] CORRECTION TO STEP 7 DESCRIPTION;[02] CABIN FLOOR PANEL 222BF WITH PULLED THROUGH INSERTS WAS REPAIRED IAW SRM 53-00-50-2R-1.;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2;[04] VERIFIED CORRECTIVE ACTIONS 1 ASDR SWAA2023080977907Panel · crackedWING BOX CENTER SECTION BREAK PANEL CRACKED AT BS 540; RBL 1; WL 207<[01] UPDATED PARTS TABLE;[02] REMOVED BREAK PANEL AT BS 540; RBL 1 WL 208 IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW BREAK PANEL IAW SRM 51-40-05-0G-0.;[03] OK TO INSTALL.;[04] LOCATED ANSDR SWAA2023080977908Panel · crackedAREA ABOVE WING BOX CENTER SECTION BREAK PANEL CRACKED AT BS 540; LBL 1; WL 207<[01] UPDATED REFERENCE TABLE;[02] REMOVED BREAK PANEL AT BS 540; LBL 1 IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW BREAK PANEL IAW SRM 51-40-05-0G-0.;[03] OK TO INSTALL;[04] LOCSDR SWAA2023081690185Floor Panel · crackedPASSENGER COMPARTMENT; SUPPORT FLOOR PANEL CRACKED AT STA 540 RBL 2'<[01] ALL STEPS COMPLETED.SDR SWAA2023081577442Floor Panel · pulledCABIN FLOOR PANEL 221BF HAS PULLED THROUGH INSERTS<[01] CORRECTIONS MADE TO STEPS 8;9 & 10 PREPARATION & APPLICATION OF PLIES TO THE OPPOSITE SURFACE.;[02] REPAIRED DAMAGED PULLED THROUGH INSERTS LOCATIONS ON CABIN FLOOR PANEL 221BF IAW SRM 53-00-50-2R-6.;[03]SDR SWAA2023081577052Panel · crackedCRACKED BREAK PANEL STA 540; LBL 1; WL 207.<[01] COMPLETED STEP 1;[02] VERIFIED CORRECTIVE ACTION ITEMS AND MEASUREMENT FIELDS; CARD COMPLETE.SDR SWAA2023081577053Panel · crackedCRACKED BREAK PANEL STA 540; RBL 1; WL 207.<[01] COMPLETED STEP 1;[02] VERIFIED CORRECTIVE ACTION ITEMS AND MEASUREMENT FIELDS; CARD COMPLETE.SDR SWIA20230709Unknown · corrodedCORROSION FOUND ON INBOARD NUTPLATE FLANGE OF FLOOR BEAM AT FS589 AND RBL9. COMPLY WITH REPAIR CRJ 700 SRM 53-00-41-201-001-A01 USING FIGURE 53-00-41-991-825, FLOOR BEAM UPPER FLANGE (SINGLE NUTPLATE) FS477.00 TO FS1088.20 (C-CHECK RO 8/16/2023) APPLIESDR SWAA2023080276661Floor Panel · delaminated`FWD GALLEY FLOORBOARD PANEL 222BF DELAMINATED FWD GALLEY FLOORBOARD PANEL 222BF DELAMINATED.<[01] REMOVED AND REPLACED FWD GALLEY PANEL 222BF WITH SERVICABLE PANEL . WILL BE INSTALLED ON CLOSE CARD [TTG8Q00L8AZF];[02] REMOVED AND REPLACED FWD GALLEY PANEL 222SDR DALA2023071005539Unknown · unknownSHIP 0667 CORROSION FLOOR BEAM UPPER FLANGE ON UPPER SURFACE BTW. LBL.64 TO RBL.27 AND STA.377.7 AT PASSENGER COMPARTMENT. CORRECTIVE ACTION: ON FLOOR BEAM UPPER FLANGE ON UPPER SURFACE BTW. LBL.64 TO RBL.27 AND STA.377.7 WAS REPAIRED PER B757-200 SRM 53-00-51SDR SWAA2023080976653Floor Panel · pulledFWD CABIN FLOOR PANEL 221BF HAS PULLED STRANDS ON UPPER SURFACE<[01] VERIFIED STEP 9;[02] FWD CABIN FLOOR PANEL 221BF WITH PULLED STRANDS ON UPPER SURFACE WAS REPAIRED PER SRM 53-00-50-2R-1.;[03] VERIFIED ALL STEPS COMPLETE;[04] VERIFIED ALL STEPS COMPLETE ANDSDR SWAA2023080176658Splice · corrodedAFT CARGO FLOOR PANEL SPLICE AT STA 767+6 HAS CORROSION<[01] RECEIVED NEW FLOOR PANEL SPLICE. SPLICE WILL BE INSTALLED WITH TASK CARD TTG8Q00L8CXN;[02] VERIFIED NEW SPLICE PROCUREMENT AND TO BE INSTALLED ON CARD <BR> TTG8Q00L8CXNSDR ASAA2023070745517Floor Panel · delaminatedFLOOR PANEL 261PF HAS DELAM AT THE FWD LH CORNER GROUNDED - YES. REMOVED AND REPLACED FLOOR PANEL 261PF WITH NEW IAW ALASKA AIRBUS A320 AMM 53-00-00-400-801-A-01. TOOL #T05867-116 CAL DUE 03/NOV/23 SEALANT TO BE ACCOMPLISHED ON ALASKA AIRLINES CUSTOMER CARD #SDR SWAA2023080376424Floor Panel · crackedCRACK FLOOR PANEL 140CF AT AFT CARGO COMPARTMENT 2023-431239<[01] REPLACED FLOOR PANEL 140CF AT AFT CARGO COMPARTMENT IAW SRM B737-700 51-10-02 ITEM 9 AND DRAWING 453A2610 REV: E;[02] CORRECTED STEP 1.<BR>REPLACED FLOOR PANEL 140CF AT AFT CARGO COMPARTMENT IAWSDR FDEA202307071281Seat Track · corrodedMAIN DECK DUMMY SEAT TRACK WAS BULGING AT -Y1456 FR54.1 AREA. REPLACED THE DUMMY SEAT TRACK WITH NEW ONE I.A.W A300-600F SRM 51-72-10-001, PAGE 2 & 51-40-21-001, PARA 6~7, PAGE 7B-50SDR SWAA2023072176388Floor Panel · corroded(A204 DOT 81) AFT CARGO FLOOR PANEL 140DF HAS CORROSION ON UPPER SURFACE AROUND PERIMITER OF FLOOR PANEL<[01] EVALUATED CORROSION AREA FOUND LENGTH OF CORRODED AREA IS MORE THAN 3' MAX ALLOWABLE LIMIT IS 3' FOUND OUT OF LIMITS I.A.W BOEING SRM 53-00-53-1A-1;[0SDR FDEA202307071174Floor Panel · dentedDENTS ON FLOOR PANEL 221DFF SECTION 41 OF MDC. FLOOR PANEL 221DFF SEC.41 OF MDC WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR.4.B FIG.201 SHEET 2 REV.85 DEC 15,2022SDR FDEA202307071173Floor Panel · dentedDENTS ON FLOOR PANEL 221CFF SECTION 41 OF MDC. FLOOR PANEL 221CFF SECTION 41 OF MDC WAS REPAIRED IAW B767 SRM 53-00-50-2R PAR.4.B FIG.201 SHEET 2 REV.85 DEC 15/2022SDR FDEA202307071172Floor Panel · dentedDENTS ON FLOOR PANEL 222AFF SECTION 41 OF MDC. FLOOR PANEL 222AFF SECTION 41 OF MDC WAS REPAIRED IAW B767 SRM 53-00-50-2R, FIG.201 SHEET 2 REV.85 DEC 15-22SDR FDEA202307071171Floor Panel · dentedDENTS ON FLOOR PANEL 222BFF SECTION 41 OF MDC. FLOOR PANEL 222BFF SECTION 41 OF MDC WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR.4.B FIG 201 REV.85 DEC 15/2022SDR FDEA202307071170Floor Panel · dentedDENTS ON FLOOR PANEL 222CFF SECTION 41 OF MDC. FLOOR PANEL 222CFF SEC.41 OF MDC WAS REPAIRED I.A.W B767 SRM 53-00-50-2R PAR.4.B FIG.201 SHEET 2 REV.85 DEC 15/2022SDR SWI2023F00202Unknown · corroded*CORROSION NOTED AT R/H FLOOR BEAM CAP AT RBL9 BETWEEN FS477-FS485 (MARKED) (C-CHECK RO 8/16/2023) BLENDED OUT CORROSION ON R/H FLOOR BEAM RBL9 BETWEEN FS477.00-FS485.00 AND FOUND OUT OF LIMITS PER CRJ700SRM 53-31-43-101-001-A02. RECEIVED AND COMPLIED W
Back to JASC 5321