SDR AALA201506129010Floor Panel · delaminated1S CHECK. CABIN FLOOR PANEL 251LF HAS DELAMINATION. REPLACED CABIN FLOOR PANEL 251LF IAW IRM 9701 REV G.SDR AALA201506109001Floor Panel · delaminated1S CHECK. CABIN FLOOR PANEL 231YH FWD OTBD CORNER DELAMINATED. REPLACED CABIN FLOOR PANEL 231YH IAW AMM 53-22-12.SDR ASOA2015070713267Floor Panel · crackedLEFT SIDE FWD EQUIPMENT COMPARTMENT, TRU, FLOOR PAN CRACKED BETWEEN OUTER SKIN EDGE AND BREAK PRESSURE GOUGES BRACKET. REPAIRED ELECTRICAL BAY FLOOR AT FS 193.00 IAW GREO 601R-53-11-111.SDR DALA2015062203890Floor Panel · damagedDAMAGE ON FERRUL AND PUNCTURE ON PAX CABIN FLOOR PANEL. FLOOR PANEL FABRICATED IAW AMM 53-20-01-201 AND INSTALLED IAW AMM 53-20-01-201.SDR FDEA201506081723Seat Track · damagedMAIN CARGO DECK RBL 57 BS 1590 SEAT TRACK DAMAGED IN TWO PLACES. SMOOTHED AND BLENDED OUT DAMAGE IAW SRM 53-00- 52-1A. FOUND OUT OF LIMITS IAW SRM 53-00-52-1A SHT 1. THE SEAT TRACK WAS REPLACED IAW SRM 53-00-52-2R.SDR IPXA2015060889951Floor Panel · dentedMAIN CARGO DECK NR 2 AFT CENTER FLOOR PANEL HAS A ONE INCH SQUARE DENT. FABRICATED A NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA2015060789901Floor Panel · damagedMAIN CARGO DECK 2R AFT OTBD FLOOR PANEL DENTED 14.5" LONG BY 1" DEEP, FABRICATED A NEW FLOOR PANEL IAW EO B767-5320-9693H.SDR SWAA2015061240649Floor Panel · crackedMAIN CABIN SUB FLOOR PANEL CRACKED AT BS 150 - 207, RIGHT SIDE. R & R THE FLOOR PANEL IAW SRM AND DRAWING.SDR IPXA2015061490135Floor Panel · crackedINSPECTION TYPE: C9, A CRACK WAS FOUND ON M/D CARGO FLOOR PANEL 241AGF, BS 984.95 - 1087, LBL 77.5 TO 88.5. FABRICATED A REPLACEMENT FLOOR PANEL IAW EO 5320-9693-H.SDR DALA2015060403626Floor Panel · corrodedFWD CARGO BAY FLOOR PANEL 131DG HAS MULTIPLE DENTS & DELAMINATED. FABRICATED A REPLACEMENT FLOOR PANEL IAW DWG NR NW3D25-40532.SDR SWIA201541263Floor Panel · damagedCARGO FLOOR PANEL 282FRF HAS DAMAGE TO TOP PLY AND CORE. REPAIRED IAW REO.SDR ASAA2015060112006Floor Panel · puncturedPARTS RACK, FWD CARGO COMPARTMENT, FLOOR PANEL 120CF IS PUNCTURED. ACFT GROUNDED. FABRICATED NEW PANEL 120CF IAW DWG 453A1610, SHEETS 51 & 52 REV A, ALODINED AND PRIMED IAW SRM 51-20-01.SDR ASAA2015060112005Floor Panel · puncturedAFT CARGO COMPARTMENT, FLOOR PANEL 140BF IS PUNCTURED. ACFT GROUNDED. FABRICATED A NEW FLOOR PANEL NR 140-BF IAW BAC DWG 453A2610, REV "E".SDR IPXA2015060189666Floor Panel · damagedMULTIPLE DAMAGES, FLOOR PANEL, PN 65B23347-40 FABRICATED NEW PANEL IAW EO 5320-57658-A.SDR IPXA2015060189665Floor Panel · delaminatedMULTIPLE DAMAGES ON FLOOR PANEL, PN 65B15754-10, FABRICATED NEW PANEL IAW EO B747-5320-57657-A.SDR IPXA2015060189609Floor Panel · damagedBS 380, MAIN CARGO FLOOR PANEL DAMAGE LBL 10.64-RBL10.64. FABRICATED A NEW FLOOR PANEL, IAW EO B747-5320-57575-A.SDR ASAA2015053116473Floor Panel · damagedFWD CARGO BAY FLOOR PANEL DENTED WITH A GOUGE AT BS 500C BL 0. ACFT GROUNDED. REMOVED DAMAGED FLOOR PANEL IAW AMM 25-52-10-00-801. FABRICATED A NEW FLOOR PANEL IAW DWG 453A1610, REV -. INSTALLED A NEW FLOOR PANEL IAW AMM 25-52-10-400-801.SDR IPXA2015060389763Floor Panel · corrodedINSPECTION TYPE: 1C, COURIER AREA FLOOR PANEL CORRODED AT BS 488, LBL40. R & R COURIER AREA FLOOR PANEL IAW DWG WSP 0788, AND SRM 51-31-01.SDR YENA20150531157Doubler · corrodedDURING HEAVY MAINTENANCE, FOUND FWD LT FLOOR DOUBLER CORRODED FRAMES 13- 16, INSTALLED NEW FLOOR DOUBLER SRM 51-41-02. PRIMED AND TOPCOAT SRM 51-23-05, 51-23-06. THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL 2 CORROSION.SDR DALA2015060903717Floorboard · delaminatedAFT FLOORBOARD DELAMINATED BEYOND SRM LIMITS, FABRICATED A NEW FLOORBOARD IAW NWD325-40640 AND REWORKED & MODIFIED IAW DWG 10N01059 SHEET 2, REV "A".SDR AALA201506019001Floorboard · debondedAFT GALLEY FLOORBOARD 261PF FOUND TO BE DISBONDED ON LT & RT SIDES. REPLACED AFT GALLEY FLOORBOARD 261PF.SDR IPXA2015053089583Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL IN POSITION 2R HAS A PUNCTURE DAMAGE LOCATED APPROX 7" AFT OF FWD EDGE. FABRICATED A NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR SWIA201541315Floor Panel · crackedFLOOR PANEL 222FLW CRACKED AT SCREW HOLE. REPAIRED THE COCKPIT FLOOR PANEL IAW EA.SDR DALA2015060303625Floor Panel · corrodedCORROSION ON FLOOR PANEL 221FF AT FWD GALLEY AREA. REPLACED FLOOR PANEL.SDR IPXA2015060689891Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XKF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689890Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XBF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689888Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 251XBF HAS DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689887Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XLF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689885Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252XCF IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689884Floor Panel · brokenINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XBF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060689883Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 221XCF IS PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-N.SDR IPXA2015060689882Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XXF HAS TORN INSERTS HOLES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789936Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XRF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789935Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XJF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789934Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789933Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252XQF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789932Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789931Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 251XEF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789930Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XWF HAS EDGE DAMGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789929Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XWF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789928Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XFF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789927Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XAF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789926Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 252XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789925Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 251XAF EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789924Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XKF IS DELAMINATED. FABRICATE A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789923Floor Panel · puncturedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XBF IS PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789922Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 221XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789921Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XNF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789920Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XQF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015060789919Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XJF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.
Back to JASC 5321