JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2015032000021Floor Panel · delaminatedFLOOR PANEL 272CF DELAMINATED. FABRICATED & INSTALLED NEW FLOOR PANEL IAW SRM 53-02-00 PARA 5I FIG 211.SDR USAA2015032000017Floor Panel · delaminatedFLOOR PANEL 252QG HAS UPPER SURFACE MATERIAL DAMAGED. FABRICATED & INSTALLED NEW FLOOR PANEL IAW SRM 53-02-00 PARA 5I FIG 211.SDR USAA2015032000016Floor Panel · delaminatedFLOOR PANEL 252UG DELAMINATED. FABRICATED & INSTALLED NEW FLOOR PANEL IAW SRM 53-02-00 PARA 5I FIG 211.SDR USAA2015032000008Floor Panel · delaminatedFLOOR PANEL 271GF DELAMINATED. FABRICATED & INSTALLED NEW FLOOR PANEL IAW SRM 53-02-00 PARA 5I FIG 211.SDR USAA2015032000007Floor Panel · delaminatedFLOOR PANEL 252RG DELAMINATED. FABRICATED NEW FLOOR PANEL & INSTALLED IAW SRM 53-02-00 PARA 5I FIG 211.SDR USAA2015032000006Floor Panel · delaminatedFLOOR PANEL 251RG DELAMINATED. FABRICATED NEW FLOOR PANEL & INSTALLED IAW SRM 53-02-00 PARA 5I FIG 211.SDR USAA2015032000005Floor Panel · delaminatedFLOOR PANEL 251HG DELAMINATED. FABRICATED NEW FLOOR PANEL & INSTALLED IAW SRM 53-02-00 PARA 5I FIG 211.SDR USAA2015032000004Floor Panel · delaminatedFLOOR PANEL 251DF DELAMINATED. FABRICATED NEW FLOOR PANEL & INSTALLED IAW SRM 53-02-00 PARA 5I FIG 211.SDR USAA2015032000003Floor Panel · delaminatedFLOOR PANEL 251XF WAS DELAMINATED. FABRICATED NEW PANEL & INSTALLED IAW SRM 53-02-00 PARA 5I FIG 211.SDR FDEA201503180972Floor Panel · damagedAFT CARGO FLOOR PANEL 151 PF DAMAGED. PANEL FABRICATED NEW ON T15 1127058, MAT A4024 48 X 144. REPAIR CLASSIFIED AS CAT A MAJOR REPAIR.SDR SWAA2015041338458Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AHF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR IPXA2015032687438Floor Panel · damagedINSPECTION TYPE:C8, MAIN CABIN FLOOR PANEL 231XTF DAMAGED AT CORNER. CORE FABRICATED FLOOR PANEL 231XTF IAW UPS SREO B757-5320-9692-H.SDR SWIA201540969Floor Skin · crackedFWD EQUIPMENT BAY FLOOR SKIN CRACKED AT LT FS 193.00 FRAME CUTOUT. C-CHECK, RO 4/1/15. REPAIRED FORWARD EQUIPMENT BAY FLOOR SKIN CRACKED AT LT FS193.00, FRAME CUTOUT REF REO COMPLIED WITH ST, SRM RII. COMPLETED FORM 337. WEIGHT CHANGE +0.036 LBS.SDR SWIA201540968Floor Skin · crackedFWD EQUIPMENT BAY FLOOR SKIN CRACKED AT RT FS 193.00 FRAME CUTOUT. C-CHECK, RO 4/1/15, REPAIRED FORWARD EQUIPMENT BAY FLOOR SKIN CRACKED AT RT FS193.00, REF STS EA. COMPLIED WITH ST CL600-2024 SRM, RII. COMPLETED FORM 337. WEIGHT CHANGE +0.23 LB.SDR IPXA2015032687433Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 252XUF HAS EDGE DAMAGE, PANEL RACK. FABRICATED IAW SREO B757-5320-9692-H APP B. REINFORCING DOUBLERS REQUIRED IAW SREO B757-5320-9692-H APPEN B. SCUFF SAND THE REPAIR AREA TO BE BONDED IAW EO B757-5320-9692-H AND SRMSDR SWAA2015042739003Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AAF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338469Floorboard · delaminatedMAIN CABIN FLOORBOARD 222ATF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338468Floorboard · delaminatedMAIN CABIN FLOORBOARD 222 AVF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338467Floorboard · delaminatedMAIN CABIN FLOORBOARD 222APF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338466Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AMF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338465Floorboard · delaminatedMAIN CABIN FLOORBOARD 222PF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338464Floorboard · delaminatedMAIN CABIN FLOORBOARD 222JF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338463Floorboard · delaminatedMAIN CABIN FLOORBOARD 222 LF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338462Floorboard · delaminatedMAIN CABIN FLOORBOARD 222AMF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338461Floorboard · delaminatedMAIN CABIN FLOORBOARD 222FF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338460Floorboard · delaminatedMAIN CABIN FLOORBOARD 222UF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR SWAA2015041338459Floorboard · delaminatedMAIN CABIN FLOORBOARD 222WF DELAMINATED. R & R FLOORBOARD IAW AMM & DWG.SDR USAA2015040200015Floor Panel · delaminated3S CHECK, AFT GALLEY FLOOR PANEL 262BG DELAMINATED. REPLACED AFT GALLEY FLOOR PANEL 262BG IAW SRM 53-02-00 & IRM 9701.SDR USAA2015032400005Floor Panel · delaminated3S CHECK, FLOOR PANEL 241HF DELAMINATED. REPLACED FLOOR PANEL 241HF IAW SRM 53-02-00 PAR 8H FIG 209 & IRM 9701 REV G.SDR FDEA201503140923Floor Panel · damagedAFT CARGO FLOOR PANEL 151SF DAMAGED. AFT CARGO FLOOR PANEL 151 SF FABRICATED ON T15 1127056. MAAT A4024 48 X 144, BATCH 2223784, CLASSIFIED AS MAJOR CAT A REPAIR.SDR IPXA2015032687432Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL NR 212XAF IS DELAMINATED, PANEL RACK. FABBED 212XAF, PN 141N5410-28 FROM A402H-48X144, BATTERY 2664589 AND ACCOMPLISHED STEP CUT IAW SREO B757-5320-9692-H APPEN B. REINFORCE STEP CUT IAW B757-5320-9692-H APPEN B. SCUSDR IPXA2015032387322Floor Panel · delaminatedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XHF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387328Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XRF IS DELALMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387332Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XMF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015031987187Floor Panel · delaminatedINSPECTION TYPE:C, MCD FLOOR PANEL 231 XCF DELAMINATED, FABRICATED NEW FLOOR PANEL 231 XCF IAW SAMPLE IAW EO B757-5320-9692-H, MATERIAL A402H-48X144 BATCH 2664589.SDR USAA2015031600005Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151VG DELAMINATED. R & R FLOOR PANEL 151VG IAW AMM 53-42-14.SDR FDEA201503130904Floor Panel · delaminatedPANEL 121 GF HAS A CORNER DELAMINATED. FLOOR PANEL 121 GF FABRICATED ON T15 1125030 IAW DWG SRZ 25-005. REPAIR CLASSIFIED AS CAT A MAJOR REPAIR.SDR FDEA201503130903Floor Panel · damagedMAIN CARGO COMPARTMENT FLOOR PANEL 231 SG UPPER SURFACE IS GOUGED & DENTED. NEW FLOOR PANEL FABRICATED ON T15 1128694 IAW SRZ-25-005. CLASSIFIED AS CATEGORY A MAJOR REPAIR.SDR FDEA201503130901Floor Panel · dentedAFT CARGO FLOOR PANEL 152 MF, LOWER SURFACE HAS MULTIPLE DENTS. FLOOR PANEL 152 MF FABRICATED ON T15 1125984 IAW DWG SRZ 25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503130900Floor Panel · gougedPANEL 162 HF SKIN SURFACE HAS GOUGES. FLOOR PANEL 162 HF FABRICATED ON T15 1128696 IAW DWG SRZ 25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503130896Floor Panel · gougedPANEL 161 GF EXTERIOR SKIN HAS GOUGES ON MULTIPLE AREAS. NEW FLOOR PANEL FABRICATED ON T15 1128692 IAW SRZ-25-005. CLASSIFIED AS CATEGORY A MAJOR REPAIR PANEL 161 GF.SDR FDEA201503130895Floor Panel · gougedPANEL 161 AF EXTERIOR SURFACE HAS GOUGE AREAS. NEW FLOOR PANELS FABRICATED ON T15 1128693 IAW SRZ 25-005. CLASSIFIED AS CATEGORY A MAJOR REPAIR PANEL 161 AF.SDR SWIA201541042Floor Panel · crackedRIGHT TRU BAY FLOOR CRACKED AT FS 193. REPAIRED CRACK IN RT FS 193, WL 79.5 TRU BAY FLOOR, REF REO.SDR SWIA201541032Floor Panel · crackedLT TRU BAY FLOOR HAS POSSIBLE CRACK AT FS 193. REPAIRED LT TRU BAY FLOOR CRACK, REF REO.SDR IPXA2015032387327Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XAF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387326Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XAF HAS EDGE DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015032387321Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR FDEA201503120875Floor Panel · crackedFLOOR PANEL 232CF CRACKED 6 INCHES FROM END. FLOOR PANEL FABRICATED AND REPLACED IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503120871Floor Panel · crackedFLOOR PANEL 261AH CRACKED. FLOOR PANEL FABRICATED AND REPLACED IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201503120832Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL 231EF HAS A MISSING INSERT. FABRICATED A NEW FLOOR PANEL IAW DWG SRZ 25-005 REV K. CLASSIFIED AS MAJOR CAT A REPAIR.
Back to JASC 5321