What was found
INSPECTION TYPE:C, MAIN DECK FLOOR PANEL NR 212XAF IS DELAMINATED, PANEL RACK. FABBED 212XAF, PN 141N5410-28 FROM A402H-48X144, BATTERY 2664589 AND ACCOMPLISHED STEP CUT IAW SREO B757-5320-9692-H APPEN B. REINFORCE STEP CUT IAW B757-5320-9692-H APPEN B. SCUFF SAND AND CLEANED THE AREA TO BE BONDED IAW SREO.