JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2015032837903Floorboard · damagedMAIN CABIN FLOOR BOARD 221ALF DAMAGED. R & R FLOORBOARD PANEL ASSEMBLY IAW MM.SDR SWAA2015032837902Floorboard · delaminatedMAIN CABIN FLOORBOARD 221AF DELAMINATED. R & R FLOORBOARD PANEL ASSEMBLY IAW MM.SDR SWAA2015032637809Floorboard · damagedMAIN CABIN FLOORBOARD 222 ACF DAMAGED. REPAIRED FLOORBOARD IAW SRM.SDR IPXA2015021786006Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF DELAMINATED. REMOVED FLOOR PANEL 231XBF MCD IAW AMM 53-01-01-024-022. 2. FABRIATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR DALA2015021701390Floor Panel · damagedFLOOR PANEL DAMAGED. FABRICATED A NEW FLOOR PANEL IAW AMM 53-20-01-201.SDR DALA2015021601358Floor Panel · corrodedCORROSION ON PAX CABIN FLOOR PANEL 160G. FLOOR PANEL REPLACED IAW DWG 9957828, SRM 51-10-3, PAR 14, 21, 51-30-2.SDR IPXA2015021685965Floor Panel · crackedINSPECTION TYPE:C11, MAIN CABIN FLOOR PANEL 333XHF HAS 2 EA DAMAGED INSERTS. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692H.SDR DALA2015022101533Floor Panel · delaminatedDELAMINATED FLOOR PANELS 120C, 160F, 389C, 541C, 769D, 826D. FLOOR PANELS NRS. 160F, 389C, 541C, 769D, 826D AND 886C. WERE FABRICATED IAW AMM 53-20-01-201. FLOOR 120C WAS INSPECTED AND NO DAMAGE WAS FOUND.SDR DALA2015022101532Floor Panel · puncturedPUNTURED PAX CABIN FLOOR PANELS NR 256D AND 886D. FLOOR PANEL NR 886D WAS FABRICATED IAW AMM 53-20-01-201. FLOOR PANEL 256D WAS WORKED IN NRC 135.SDR USAA2015022000010Floor Panel · corroded1S CHECK, AFT CABIN DOOR SILL FLOOR PANEL 271LF CORRODED. REPLACED PANEL 271LF IAW SRM 51-42-11.SDR IPXA2015021886058Floor Panel · damagedINSPECTION TYPE:C11, MAIN CARGO CABIN FLOOR PANEL 231XWF IS CRUSHED IN SEVERAL PLACES. FABRICATED NEW FLOORBOARD.SDR DALA2015021501344Floor Panel · crackedCRACKED SKIN ON FLOOR PANEL 1003A. FLOOR PANEL REPLACED IAW SRM 51-10-4, 51-10-3 PAR 21 AND 14.SDR USAA2015021500023Floor Panel · damagedSOFT SPOT ON FLOOR OF AFT GALLEY, REF LOG PAGE 8914139. REPLACED CTR AFT GALLEY FLOOR PANEL IAW AMM 53-12-12.SDR DALA2015022701712Floor Panel · debondedBROKEN FLOOR PANEL AND DISBONDED CHANNEL. FLOOR PANEL WAS REPAIRED AND BONDED IAW SRM 51-70-1 D AND DPS 1.07-39.SDR DALA2015021401248Floor Panel · delaminatedDURING INSPECTION, FOUND CORROSION ON FLOOR PANEL 261FF AT AFT GALLEY AREA. REPLACED FLOOR PANEL 261FF AT AFT GALLEY AREA AND INSTALLATION IS DOCUMENTED IN AMDS 2500-6602.SDR DALA2015021501348Floor Panel · delaminatedDELAMINATED FLOOR PANEL. FABRICATED A NEW FLOOR PANEL IAW AMM 53-20-01-201 AND PS900-5-2 NR 2.SDR DALA2015021301311Floor Panel · crackedCRACKED FLOOR PANEL CHANNEL. FLOOR PANELS WERE REPAIRED IAW SRM 53-05, FIG 131C.SDR DALA2015021301289Pressure Deck · crackedCABIN OVERWING CANTED PRESSURE DECK INTERNAL CROSS DRAIN PATH FOUND CORRODED AT BS 955 BETWEEN LBL 2 - 10. REPAIRED.SDR DALA2015021401253Floor Panel · damagedDURING INSPECTION, FOUND CABIN FLOOR PANEL 232 FF HAS A HOLE. FABRICATED A NEW FLOOR PANEL IAW DWG NW3025-37498 AND INSTALLED.SDR DALA2015021401251Floorboard · damagedDURING INSPECTION, FOUND CABIN FLOORBOARD 231CF HAS HOLE. FABRICATED A NEW FLOORBOARD IAW DWG NW3025-37498 AND INSTALLED ON CARD 2500-6601.SDR DALA2015021401250Floor Panel · damagedDURING INSPECTION, FOUND FLOOR PANEL 231 QF HAS FACE SKIN DAMAGE. FABRICATED NEW FLOOR PANEL IAW NW3025-37498.SDR C77A20150215003Doubler · corrodedFORWARD CABIN FLOOR, LT FWD FLOOR DOUBLER, HAS CORROSION AT FRAME 16 X= 4711 Y= -723.9. BLENDED CORRODED AREAS IAW SRM 51-10-03 & 51-12-01.SDR C77A20150215002Doubler · corrodedFORWARD CABIN FLOOR LT AFT DOUBLER, BETWEEN FRAME 19 - 20 HAS CORROSION X= 5645 - 6070 Y= -635. BLENDED CORRODED AREAS IAW SRM 51-10-03 & 51-12-01.SDR C77A20150215001Doubler · corrodedFORWARD CABIN FLOOR, RT AFT DOUBLER, HAS LIGHT CORROSION ON UPPER SURFACE FRAME 18, X= 5323 Y= +406. BLENDED CORRODED AREAS IAW SRM 51-10-03 & 51-12-01.SDR IPXA2015021385870Floor Panel · damagedINSPECTION TYPE: 5YR, FLOOR PANEL 231WG IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO.SDR IPXA2015021385868Floorboard · damagedINSPECTION TYPE: 5YR, FLOOR PANEL 231RG IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO.SDR IPXA2015021385867Floorboard · damagedINSPECTION TYPE: 5YR, FLOORBOARD 251PG IS BROKEN. FABRICATED A NEW FLOORBOARD SREO.SDR SWAA2015032637802Floor Panel · corrodedR1 DOOR, LOWER JAMB AREA FLOOR PANEL UPPER SURFACE CORRODED FWD & AFT OF ESCAPE SLIDE GIRT BAR FITTINGS. R & R SURFACE IAW SRM & DWG.SDR SWIA201540779Floor Panel · crackedPRESSURE FLOOR CRACKED AT FS 462 AND LBL 4.0 TO LBL 6.0, MARKED. (C-CHECK RO 2/28/15)REPAIRED PRESSURE FLOOR CRACKED AT FS 462 AND LBL 4.0 TO LBL 6.0, REF REO. NO LEAKS NOTED, COMPLIED WITH ST.SDR DALA2015022001510Deck Plate · corrodedMAIN CABIN AFT DECK PLATE PREVIOUS REPAIR DOUBLER CORRODED STA 1715, RBL 23. REMOVED REPAIR DOUBLE FABRICATED REPAIR AND INSTALLED IAW SRM.SDR IPXA2015021886052Floorboard · crackedINSPECTION TYPE:C11, MAIN CABIN FLOORBOARD 232XGF IS CRACKED. FABRICATED A NEW FLOORBOARD.SDR IPXA2015021685992Floorboard · damagedINSPECTION TYPE: 5YR, MAIN CABIN FLOORBOARD 222DG DAMAGED. FABRICATED NEW FLOORBOARD IAW REO 5320-16407.SDR IPXA2015021685991Floorboard · damagedINSPECTION TYPE: 5YR, MAIN CARGO FLOORBOARD 242LM DAMAGED. FABRICATED A NEW FLOORBOARD IAW EA 5320-16407.SDR IPXA2015021685988Floor Panel · damagedINSPECTION TYPE: 5YR, FLOOR PANEL 242SH BROKEN. FABRICATED NEW FLOOR PANEL IAW SREO 5320-16407-E.SDR IPXA2015021385864Floorboard · damagedINSPECTION TYPE: 5 YR, FLOOR PANEL 231NJ IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO.SDR IPXA2015021385863Floor Panel · damagedINSPECTION TYPE: 5YR, FLOOR PANEL 231HG IS BROKEN. FABRICATED NEW IAW SREO.SDR IPXA2015021285844Floor Panel · damagedINSPECTION TYPE: 5YR, CABIN FLOOR PANEL 231MJ FWD END DAMAGED FR20-FR21, LBL 78 LBL95. FABRICATED NEW FLOOR BOARD IAW SREO A300-5320-16407-E.SDR IPXA2015021385872Floor Panel · damagedINSPECTION TYPE: 5YR, CABIN FLOOR PANEL CRACKED 221EG FROM 18-FR19 LBL 36-LBL 45. FABRICATED NEW FLOOR PANEL IAW SREO.SDR IPXA2015021385862Floorboard · damagedINSPECTION TYPE: 5YR, FLOOR PANEL NR 241-QJ IS BROKEN FABRICATED A NEW FLOORBOARD IAW SREO.SDR IPXA2015021385861Floorboard · damagedINSPECTION TYPE: 5YR, FLOORBOARD NR 231-SG IS BROKEN. FABRICATED NEW FLOORBOARD IAW SREO.SDR IPXA2015021285831Floor Panel · damagedINSPECTION TYPE: 5YR, FLOOR PANEL 232XG BROKEN. FABRICATED NEW FLOOR PANEL IAW EO.SDR ASAA2015021010775Floor Panel · corrodedFLOOR PANEL AT COCKPIT ENTRANCE, FS270-FS280, BL0, HAS CORROSION ON LOWER SURFACE BS 270-BS 280, BL 0. ACFT GROUNDED. R & R PANEL IAW SRM 51-40-02, DWG 141A5133, DOT REMOVED.SDR IPXA2015021685968Floorboard · crackedINSPECTION TYPE: C11, MAIN CABIN FLOORBOARD 231XHR IS CRACKED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2015022486411Floor Panel · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOOR PANEL 231WG BROKEN/CRACKED. FABRICATED NEW FLOORBOARD IAW EO A300-5320-40552-B.SDR IPXA2015022486410Floor Panel · damagedINSPECTION TYPE:10YR, MAIN CABIN FLOOR PANEL 232LF BROKEN/CRACKED. FABRICATED NEW PANEL IAW EO A300-5320-40552-B.SDR IPXA2015021986108Floor Panel · crackedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 242XDF CRACKED AT EDGE. FABBED PANEL 242XDF PN 144N5361-11 FROM A402H-48X144, BAT 2664589 IAW SREO 5320-9692-H.SDR IPXA2015021986106Floor Panel · puncturedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 242XCF DENTED AND PUNCTURED. 53-37 FABBED PANEL 242XCF, PN 144N5361-54 FROM A402H-48X144, BAT 2664589 IAW SREO B757-5320-9692-H.SDR IPXA2015020985626Floor Panel · damagedFLOOR PANEL BS 972-1043 DENTED AND PUNCTURED. REPAIRED IAW SRM 53-00-50-2R, STEP 2.SDR IPXA2015020985625Floor Panel · damagedDAMAGED FLOOR PANEL MAIN DECK, PN 145T5876-82 FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H & EOB767-5320-56659.SDR IPXA2015031286937Floor Panel · dentedINSPECTION TYPE:C9, FOUND DENT, M/D CARGO FLOOR PANEL, 241MFF BETWEEN STA 412-STA 533, LBL 11-LBL-33 FABRICATED THE REPLACEMENT FLOOR PANEL IAW EO B767-5320-9693-H.
Back to JASC 5321