What was found
INSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF DELAMINATED. REMOVED FLOOR PANEL 231XBF MCD IAW AMM 53-01-01-024-022. 2. FABRIATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF DELAMINATED. REMOVED FLOOR PANEL 231XBF MCD IAW AMM 53-01-01-024-022. 2. FABRIATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.