JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016112209173Floor Panel · corrodedCORROSION ON FLOOR PANEL 221LF ALL INSERT AT FWD GALLEY AREA. REPLACED THE FLOOR PANEL.SDR DALA2015012300601Floor Panel · delaminatedDELAMINATED FLOOR PANEL. FLOOR PANEL FABRICATED IAW AMM 53-20-01-201.SDR IPXA2015012685442Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XCF DETERIORATED HONEYCOMB AT EDGE 143-491. FABBED PANEL 232XCF, PN 143N5457-82 FROM A402H-48X144, BATCH 2613192 IAW SERO 5320-9692-H. 2. STEP OUT REQUIRED IAW SREO 5320-9692-H3. SCUFF SAND AROUND THE STEP CUTSDR IPXA2015012185385Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XTF DETERIORATED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO-5320-9692-H.SDR IPXA2015012185384Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XTF WITH TOOL DAMAGE. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185383Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XQF DAMAGED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185382Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XMF WITH DENT & TOOL DAMAGE. FABRICATED A NEW FLOOR PANEL IAW REO B757-5320-9692-H.SDR IPXA2015012185381Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XCF HAS DETERIORATED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015012185380Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF DETERIORATED AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185379Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XNF MISSING, AND DAMAGED HONEYCOMB. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185375Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XEF DENTED AND SCRATCHED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185374Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XDF DENTED AT THE EDGE AND MISSING HONEY COMB. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015012185372Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 221XCF DENTED AND TOOL DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185371Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XRF DETERIORATED HONEYCOMB. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185368Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 231XDF DETERIORATED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185366Floor Panel · damagedINSPECTION TYPE: CP 11, MAIN DECK FLOOR PANEL 232XBF MISSING HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185365Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 231XKF MISSING HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185363Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 231XPF HAS DETERIORATED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185362Floor Panel · crackedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XGF CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185357Floor Panel · damagedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 232XVF HAS DAMAGED HONEYCOMB AT THE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185356Floor Panel · dentedINSPECTION TYPE: CP11, MAIN DECK FLOOR PANEL 221XBF DENTED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR DALA2016112209174Floor Panel · corrodedCORROSION ON CABIN FLOOR PANEL 222FF. REPLACED THE CABIN FLOOR PANEL.SDR ASAA2015011210543Floor Panel · crackedAFT CARGO BAY FLOOR PANEL IS CRACKED. ACFT GROUNDED. FABRICATED A NEW FLOOR PANEL IAW SRM 51-40-05, SRM 51-20-01 AND SOPM 20-41-02.SDR DALA2015012400631Floor Panel · delaminatedDELAMINATED FLOOR PANEL. FLOOR PANEL FABRICATED IAW AMM 53-20-01-201.SDR IPXA2015012185378Floor Panel · crackedINSPECTION TYPE: C, FLOOR PANEL 232XFF IS CRACKED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185370Floor Panel · damagedINSPECTION TYPE: CP11, FLOOR PANEL 232XYF HAS DAMAGE INSERT. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185364Floor Panel · dentedINSPECTION TYPE: CP11, FLOOR PANEL 232XWF HAS A DENT AT THE CORNER. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185355Floor Panel · damagedINSPECTION TYPE:CP11, FLOOR PANEL 231XWF MISSING AN INSERT. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H .SDR IPXA2015012185354Floor Panel · dentedINSPECTION TYPE:CP11, FLOOR PANEL 232XXF HAS A DENT. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015012185353Floor Panel · dentedINSPECTION TYPE: CP11, FLOOR PANEL 231XYF HAS DENT. FABRICATEDED A NEW FLOOR PANEL IAW SREO 5320-9692-W.SDR FDEA201501120121Floor Panel · damagedFLOOR PANEL 161AF DAMAGED. FLOOR PANEL 161AF FABRICATED ON T14 111858 IAW DWG SRZ 25-0. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201501120120Floor Panel · damagedFLOOR PANEL 161BF DAMAGED. FLOOR PANEL 161BF FABRICATED ON T14 111859 IAW DWG SRZ 25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201501120119Floor Panel · crackedAFT CARGO FLOOR PANEL 151UF IS CRACKED AT CORNER FLOOR PANEL 151UF. FABRICATED ON T14 1114496 IAW DWG SRZ25-005. CLASSIFIED AS CAT A MAJOR.SDR USAA2015011300008Floor Panel · crackedC2 CHECK CRACK IN FLOOR PANEL 131AG BETWEEN FRAME 37 TO 37.4 & BETWEEN Y1959 TO Y2462. REPLACED FLOOR PANEL 131AG IAW SRM 53-02-00 FIG 211.SDR USAA2015011300007Floor Panel · crackedC2 CHECK CRACK IN FLOOR PANEL 131PF BETWEEN FRAME 26.3 TO 30 & BETWEEN Y2462 TO Y1959. REPLACED FLOOR PANEL 131PF IAW SRM 53-02-00 FIG 211.SDR DALA2016112209175Floor Panel · corrodedCORROSION ON FLOOR PANEL 221EF INSERT AT FWD GALLEY AREA. REPLACED THE FLOOR PANEL IAW SRM.SDR IPXA2015012685446Floor Panel · delaminatedINSPECTION TYPE: CP11, MCD FLOOR PANEL 231XMF BOTTOM HONEYCOMB PROTECTIVE LAYER IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H2.SDR IPXA2015012685445Floor Panel · delaminatedINSPECTION TYPE:CP11, MCD FLOOR PANEL 231XFF RT SIDE EDGE IS DELAMINATED THE ENTIRE LENGTH OF THE PANEL. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185377Floor Panel · damagedINSPECTION TYPE: CMCD, FLOOR PANEL 231XLF DAMAGE TO THE HONEYCOMB ON ONE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR ASAA2015011010269Floorboard · crackedBS 540, LBL 40 LOWER SURFACE FLOORBOARD DAMAGED. ACFT GROUNDED. R & R THE FLOORBOARD IAW SRM 51-40-02.SDR IPXA2015011685306Floor Panel · damagedFLOOR PANEL 231XNF, HONEYCOMB MATERIAL IS RIPPED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685304Floor Panel · damagedINSPECTION TYPE: CMCD, FLOOR PANEL 231XAF HAS SEVERAL DENTS AND HONEYCOMB MATERIAL MISSING AT FWD AND AFT EDGES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685303Floor Panel · damagedINSPECTION TYPE:CMCD, FLOOR PANEL 232XUF HAS DAMAGED HONEYCOMB. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685302Floor Panel · damagedINSPECTION TYPE: CMCD, FLOOR PANEL 231XSF HONEYCOMB IS DAMAGED AT SEVERAL SPOTS AROUND THE EDGES. FABRICATED A NEW FLOOR PANELIAW SREO B757-5320-9692-H.SDR USAA2015011300009Floor Panel · crackedC2 CHECK CRACK IN FLOOR PANEL 131DG BETWEEN FRAME 37.4 TO 39.1 & BETWEEN Y953 TO Y1465. REPLACED FLOOR PANEL 131DG IAW SRM 53-02-00 FIG 211 & 53-00-00.SDR SWIA201502040699Floor Panel · corrodedFLOOR PANEL BS 409+128 - 559 CORRODED. REPAIRED IAW REO.SDR IPXA2015012685444Floorboard · damagedINSPECTION TYPE: CP11, MAIN DECK FLOORBOARD 252XUF DAMAGED IN CORNER 122-0141. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H, PN 146N5361-45.SDR IPXA2015012685443Floor Panel · delaminatedINSPECTION TYPE: CP 11, PANEL RACK MAIN DECK FLOOR PANEL 251XQF HAS A AREA OF DELAMINATION AT PREVIOUS. FABBED PANEL 251XQF, PN 146N5361-15 FROM A402H-48X144 IAW SREO B757-5320-9692-H2. STEP B2 OF SREO B757-5320-9692-H REQUIRED. SCUFF SAND AROUND THE STEP CSDR IPXA2015011685312Floorboard · puncturedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 252XEF HAS PUNCTURE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2010116585311Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 241XMF DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO 5320-9692-H.
Back to JASC 5321