What was found
INSPECTION TYPE: CP11, MCD FLOOR PANEL 231XMF BOTTOM HONEYCOMB PROTECTIVE LAYER IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: CP11, MCD FLOOR PANEL 231XMF BOTTOM HONEYCOMB PROTECTIVE LAYER IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H2.