JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201412160075Floor Panel · crackedAFT PIT FLOOR PANEL 151CF IS CRACKED AT A CORNER. FLOOR PANEL 151CF FABRICATED ON T14 1111394 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412164211Floor Panel · crackedFLOOR PANEL 241VG DAMAGED FRAME 54.2 - 55 MAIN DECK CRACK. FLOOR PANEL 241VG FABRICATED ON T14 1110365 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR DALA2014121706566Floor Panel · delaminatedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261DF DELAMINATED. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00. REMOVED AND REPLACED THE FLOOR PANEL.SDR FDEA201412130023Floor Panel · crackedFLOOR PANEL 251DL DAMAGED CRACK. FLOOR PANEL 251DL FABRICATED ON T14 1110374 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412130022Floor Panel · damagedFLOOR PANEL 252BF DAMAGED FRAME 55 - 57.1 MAIN DECK. FLOOR PANEL 252BF FABRICATED ON T14 1110368 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412130021Floor Panel · damagedFLOOR PANEL 251BF DAMAGED FRAME 55 - 57.1 MAIN DECK. FLOOR PANEL 251BF FABRICATED ON T14 1110363 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412134215Floor Panel · crackedFLOOR PANEL 232BH IS CRACKED. FLOOR PANEL 232BH FABRICATED ON T14 1110375 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412134214Floor Panel · damagedFLOOR PANEL 251RG DAMAGED FRAME 57.1 TO 58 MAIN DECK. FLOOR PANEL 251RG FABRICATED ON T14 1110372 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412134213Floor Panel · damagedFLOOR PANEL 251YG DAMAGED FRAME 60 - 65 MAIN DECK. FLOOR PANEL 251YG FABRICATED ON T14 1110370 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412134212Floor Panel · damagedFLOOR PANEL 251PH DAMAGED FRAME 58 TO 60 MAIN DECK. FLOOR PANEL 251PH FABRICATED ON T14 1110369 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412134210Floor Panel · damagedFLOOR PANEL 251NG DAMAGED FRAME 55 - 57.1 MAIN DECK. FLOOR PANEL 251NG FABRICATED ON T14 1110364 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412134209Floor Panel · damagedFLOOR PANEL 242TG DAMAGED FRAME 54 - 54.2 MAIN DECK. FLOOR PANEL 242TG FABRICATED ON T14 1110362 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412134208Floor Panel · crackedFLOOR PANEL 241EJ DAMAGE, CRACK, FRAME 54 MAIN DECK. FLOOR PANEL 241EJ FABRICATED ON T14 1110361 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412134207Floor Panel · damagedFLOOR PANEL 251BH HAS EDGE & CORE DAMAGE FRAME 65 & 69 MAIN DECK. FLOOR PANEL 251BH FABRICATED ON T14 1110360 IAW DWG SRZ-25-005. REPAIR CLASSIFIED AS CAT A MAJOR.SDR SWIA201440467Floor Panel · crackedRIGHT TRU BAY FLOOR PANEL CRACKED AT BS 193. REPAIRED THE FLOOR PANEL IAW REO.SDR FDEA201412124206Floor Panel · puncturedBULK CARGO FLOOR PANEL 162HF HAS .5 INCH DEEP PUNCTURES ON UPPER SURFACE, FRAME 66 - 70. FLOOR PANEL 162HF FABRICATED ON T14 1109907 IAW DWG SRZ-25-011. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412124205Floor Panel · puncturedBULK CARGO FLOOR PANEL 161JF HAS .5 INCH DEEP PUNCTURES ON UPPER SURFACE, FRAME 66 - 70. FLOOR PANEL 161JF FABRICATED ON T14 1109908 IAW DWG SRZ-25-011. REPAIR CLASSIFIED AS CAT A MAJOR.SDR FDEA201412124204Floor Panel · puncturedBULK CARGO FLOOR PANEL 161GF HAS SEVERAL PUNCTURES ON UPPER SURFACE APPROX .5 INCH DEEP, FRAME 66 - 70, FLOOR PANEL 161GF. FABRICATED ON T14 1109906 IAW DWG SRZ-25-011. REPAIR CLASSIFIED CAT A MAJOR.SDR USAA2014121500019Floor Panel · delaminatedSYS 6 CHECK, DELAMINATION ON FLOOR PANEL 261HG BETWEEN FRAME 64 TO 66, Z-500 & BETWEEN Y1589 TO Y512.5. REPLACED FLOOR PANEL 261HG IAW IRM 9701 REV G.SDR USAA2014121500018Floor Panel · delaminatedSYS 6 CHECK, DELAMINATION ON FLOOR PANEL 262GF BETWEEN FRAME 68 TO 70, Z-500 & BETWEEN Y1162.5 TO -Y1162.5. REPLACED FLOOR PANEL 262GF IAW IRM 9701 REV G.SDR DALA2014121306526Floor Panel · crackedDURING INSPECTION, FOUND CRACK ON FLOOR PANEL 241HF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, FIG 209 .SDR DALA2014121306521Floor Panel · delaminatedDURING INSPECTION, FOUND DELAMINATE FLOOR PANEL 222FF. REPLACED THE FLOOR PANEL IAW AMM 53-12-12.SDR USAA2014121200012Floor Panel · delaminatedSY6 CHECK, DELAMINATION ON FLOOR PANEL 221DF BETWEEN FRAME 16 TO 21, Z-500, Y0, REPLACED FLOOR PANEL 221DF IAW IRM 9701 REV G.SDR USAA2014121200011Floor Panel · delaminatedS1 CHECK, DELAMINATION ON FLOOR PANEL 132DG BETWEEN FRAME 37.4 TO 39.1 & BETWEEN -Y860 TO -Y1400. REPLACED FLOOR PANEL 132DG IAW SRM 53-02-00 PARA 5 I FIG 211.SDR USAA2014121200010Floor Panel · delaminatedS1 CHECK, DELAMINATION ON FLOOR PANEL 162EF BETWEEN FRAME 69 TO 73 & BETWEEN Y0 TO Y1020. REPLACED FLOOR PANEL 162EF IAW SRM 53-02-00 PARA 5 I FIG 211.SDR USAA2014121200009Floor Panel · delaminatedS1 CHECK, DELAMINATION ON FLOOR PANEL 131KG BETWEEN FRAME 36 TO 37.4 & BETWEEN Y860 TO Y1400. REPLACED FLOOR PANEL 131KG IAW SRM 53-02-00 PARA 5 I FIG 211.SDR USAA2014121200008Floor Panel · delaminatedS1 CHECK, DELAMINATION ON FLOOR PANEL 131CG BETWEEN FRAME 37.4 TO 39.1 & BETWEEN Y860 TO Y1400. REPLACED FLOOR PANEL 131CG IAW SRM 53-02-00 PARA 5 I FIG 211.SDR USAA2014121000018Floor Panel · delaminatedS1 CHECK, DELAMINATION ON UPPER SURFACE OF FLOOR PANEL 132CG BETWEEN FRAME 37.4 TO 39.1 & BETWEEN -Y200 TO -Y720. REPLACED FLOOR PANEL 132CG IAW SRM 53-02-00 PARA 5 I FIG 211.SDR USAA2014121000017Floor Panel · delaminatedS1 CHECK, DELAMINATION ON UPPER SURFACE OF FLOOR PANEL 131HG BETWEEN FRAME 31 TO 36 & BETWEEN Y860 TO Y1400. REPLACED FLOOR PANEL 131HG IAW SRM 53-02-00, PARA 5 I FIG 211.SDR DALA2016112309183Floor Panel · corrodedCORROSION ON FLOOR PANEL 221DF INSERT AT FWD GALLEY AREA. REPLACED THE FLOOR PANEL IAW SRM.SDR DALA2014121006476Floor Panel · damagedDURING INSPECTION, FOUND L1 ENTRY FLOOR PANEL 221FF HAS BROKEN CORNER.SDR DALA2014121006475Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151LF HAS SIDE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006474Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151GF PUNCTURED IN MULTIPLE AREAS. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006473Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161AF HAS SIDE DAMAGE HAS WELL AS DELAMINATION. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006472Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO SLOPE PANEL 151FF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006471Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO SLOPE PANEL 152BF HAS EDGE DAMAGE. FABRICATED A NEW PANEL IAW SRM 53-02-00.SDR DALA2014121006470Floor Panel · puncturedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151DF PUNCTURED IN MULTIPLE AREAS. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006469Floor Panel · crackedDURING INSPECTION, FOUND MAIN CABIN FLOOR PANEL 241HF CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00.SDR DALA2014121006482Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO BAY SLOPING PANEL 152NF PUNCTURED & MULTIPLE DENTS. FABRICATED A NEW PANEL 152NF IAW DWG 3D25-37705.SDR DALA2014121006480Floor Panel · corrodedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 262AB HAS SEVERAL CORRODED INSERTS. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00 AND DWG 3D25-37498.SDR DALA2014121006479Floor Panel · corrodedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261NF HAS SEVERAL CORRODED WASHERS AND INSERTS. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00 AND DWG 3D25-37798.SDR DALA2014121006478Floor Panel · delaminatedDURING INSPECTION, FOUND MAIN CABIN FLOOR PANEL 231MF CRACKED. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00 AND DWG 3D25-37498.SDR DALA2014121006477Floor Panel · delaminatedDURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261PF HAS CORRODED INSERTS AND DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SRM 53-02-00 AND DWG 3D25-37498.SDR USAA2014120900006Floor Panel · wornAFT CARGO ENTRANCE FLOOR PANEL 151ZG IS WORN THROUGH WITH HONEYCOMB VISIBLE AT FRAME 57+6 AT OTBD EDGE OF PANEL & 7.750 INCHES IN FROM AFT EDGE.SDR DALA2014120906444Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO BAY FLOOR PANEL 131AF WITH MULTIPLE DENTS, PUNCTURES & EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW DWG 3D25-37705, REV - G.SDR DALA2014120906443Floor Panel · delaminatedDURING INSPECTION, FOUND FWD CARGO BAY FLOOR PANEL 131BF TOP SKIN LIFTED & DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW DWG 3D25-37705, REV-G.SDR DALA2014120906442Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO BAY FLOOR PANEL 131FF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW DWG 3D25-37705, REV-G.SDR USAA2014120800014Floor Panel · delaminatedC2 CHECK DELAMINATION ON FLOOR PANEL 162EF BETWEEN FRAME 69 TO 73 & BETWEEN -Y1246 TO 0. REPLACED FLOOR PANEL 162EF IAW SRM 53-02-00 PARA 5I FIG 211.SDR SWIA201440527Floor Panel · corrodedLEFT FLOOR PANEL FROM BS 409.128 - 559 HAS CORROSION. BLENDED CORROSION IAW REO.SDR SWIA201440526Floor Panel · corrodedRIGHT FLOOR PANEL FROM BS 409.128 559 HAS CORROSION. REMOVED CORROSION IAW REO.
Back to JASC 5321