What was found
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261DF DELAMINATED. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00. REMOVED AND REPLACED THE FLOOR PANEL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND AFT UTILITY FLOOR PANEL 261DF DELAMINATED. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00. REMOVED AND REPLACED THE FLOOR PANEL.