JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2013071100025Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 262BG BETWEEN FR64 TO FR66 & BETWEEN -Y1732 TO -Y765. REPLACED FLOOR PANEL 262BG IAW SRM 53-02-00, TABLE 103, FIG 209 AND IRM 9701, REV G.SDR USAA2013071100024Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 222CF BETWEEN FR12 TO FR16 AND BETWEEN Y254 TO -Y1732. REPLACED FLOOR PANEL 222CF IAW SRM 53-12-00, FIG 206 AND IRM 9701, REV G.SDR USAA2013071100023Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 222EF BETWEEN FR16 TO FR20 AND BETWEEN -Y254 TO -Y1292. REPLACED FLOOR PANEL 222EF IAW SRM 53-12-00, FIG 206 AND IRM 9701, REV G.SDR USAA2013071100021Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 232EF BETWEEN FR20 TO FR24 & BETWEEN -Y765 TO -Y1292. REPLACED FLOOR PANEL 232EF IAW SRM 53-12-00, FIG 206 AND IRM 9701, REV G.SDR DALA13032163162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 231XG DELAMINATED. REMOVED AND INSTALLED FLOOR PANEL IAW MM 53-42-12, PB 401 AND SRM 51-42-12. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR UALA2013062404380Pressure Deck · corrodedAFT PRESSURE DECK BS 1681.8, PLUS 4 INCHES, RBL 55.0 FOUND TRACES OF CORROSION ON EXISTING DOUBLER REPAIR. MAJOR REPAIR ACCOMPLISHED: REMOVED AND INSTALLED NEW DOUBLER IAW B757-200 SRM 51-40-08, PGS 5-7,51-20-05 PGS 201-203, 51-40-02 PGS 1&2 & ECRA 5330-04259SDR UALA2013062404373Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151VG DELAMINATED ABOUT 36 BY 12 INCHES. REPLACED FLOOR PANEL IAW MM.SDR UALA2013062404372Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151ZG DELAMINATED ABOUT 21 BY 27 INCHES. FLOOR PANEL REPLACED IAW MM.SDR FDEA201306211366Floor Skin · misrepairedCOCKPIT FLOOR UNDERNEATH OBSERVER SEAT AT BS 360 MISREPAIRED. REPAIRED IAW SRM 53-10-51 FIGURE 201 REPAIR 1 REVISION 52 & EO 1-5100-7-5001 B3 PART 1. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100 REVISION 116.SDR DALA13032103162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 231CF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13032093162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 232DF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13032083162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222CF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR USAA2013062400050Floor Panel · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR PANEL 261LG BETWEEN FR66 TO FR68, Y1732. REPLACED FLOOR PANEL 261LG IAW SRM 53-42-12, 51-42-11 & 51-73-11.SDR USAA2013062400049Floor Panel · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR PANEL 221FF BETWEEN FR16 TO FR20, Y1732. REPLACED FLOOR PANEL 221FF IAW SRM 53-42-12, 51-42-11 & 51-73-11.SDR USAA2013062400048Floor Panel · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR PANEL 222FF BETWEEN FR16 TO FR20 & BETWEEN -Y1292 TO -Y1732. REPLACED FLOOR PANEL 222FF IAW SRM 53-42-12, 51-42-11 & 51-73-11.SDR DALA13031379205Web · corrodedPASSENGER CABIN FORWARD WET AREA FLOOR STRUCTURE RT SIDE BS 200, RBL 50, MEMBRANE WEB CORRODED. TASK 53-211-01. 100 PERCENT MATERIAL LOSS. CUTOUT DAMAGE, INSTALLED REPLACEMENT WEB AND DOUBLER IAW SRM 51-11-01.SDR IPXA13579180Floorboard · damagedINSPECTION TYPE:S4C4, MAIN DECK FLOORBOARD 242XAF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW B757-532 0-9692-H.SDR IPXA13579179Floorboard · damagedINSPECTION TYPE:S4C4, MAIN DECK FLOORBOARD 242XEF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW B757-543 20-9692-H.SDR IPXA13579178Floorboard · damagedINSPECTION TYPE:S4C4, MAIN DECK FLOORBOARD 242XBF EDGE DAMAGED. FABRICATED NEW FLOORBOARD IAW B757-532 0-9692-H.SDR IPXA13579177Floorboard · damagedINSPECTION TYPE:S4C4, MAIN DECK FLOORBOARD 242XJF HAS EDGE DAMAGE (PANEL RACK). FABRICATED NEW FLOORBOARD IAW B757-532 0-9692-H.SDR IPXA3679015Floor Panel · delaminatedINSPECTION TYPE:C9, FOUND DELAMINATION DAMAGE ON M/D CARGO FLOOR PANEL AT BS 482-490 ,LBL 78.5-88, DIMENSIONS OF DAMAGE: 9" X 7". REPAIR IAW EO B767-5320-9693-H.SDR IPXA3679014Floor Panel · dentedINSPECTION TYPE:C9, FOUND DENT DAMAGE ON CARGO FLOOR PANEL AT BS 573-584, LBL 75. DIMENSION OF CRACK DAMAGE: 9 INCHES LONG. REPAIR IAW EO B767-5320-9693-H.SDR DALA13030803162Floor Panel · corrodedAFT UTILITY FLOOR PANEL 262FF CORRODED 3" X 3". NEW FLOOR PANEL INSTALLED.SDR DALA13030793162Floor Panel · corrodedFWD UTILITY FLOOR PANEL 221FF CORRODED 3" X 3". PANEL INSTALLED.SDR DALA13030783162Floor Panel · delaminatedFWD UTILITY FLOOR PANEL 221PF DELAMINATED 4" X 4". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030773162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221DF DELAMINATED 12" X 8". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030763162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222EF DELAMINATED 8" X 4". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030753162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 231FF DELAMINATED 6" X 4". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030743162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 232FF DELAMINATED 5" X 4". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030733162Floor Panel · puncturedMAIN CABIN FLOOR PANEL 231MF PUNCTURED 1.5" X 1.5". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030723162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 231LF DELAMINATED 4" X 4". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030713162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241FF DELAMINATED 5" X 5". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030703162Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251JF DELAMINATED 3" X 3". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030693162Floor Panel · delaminatedAFT UTILITY FLOOR PANEL 262EF DELAMINATED 7" X 4" LONG. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DRWG 3D25-40640.SDR DALA13030683162Floor Panel · delaminatedAFT UTILITY FLOOR PANEL 261DF DELAMINATED 6" X 5" LONG. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030673162Floor Panel · delaminatedAFT UTILITY FLOOR PANEL 261NF DELAMINATED 5" X 5". FABRICATED FLOOR PANEL IAW SRM 53-02-00 FIG 209 AND DWG 3D25-40640.SDR DALA13030663162Floor Panel · delaminatedAFT UTILITY FLOOR PANEL 262AB DELAMINATED 4" X 4". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13030653162Floor Panel · corrodedAFT UTILITY FLOOR PANEL 261PF HAS CORRODED INSERTS 1" X 1". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640. TO BE INSTALLED ON WC 2500-6602.SDR USAA2013071100029Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 151GF BETWEEN FR52 TO FR56 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL 151GF IAW SRM 53-02-00, PAR. 8H, FIG 209 AND IRM 9701, REV G.SDR USAA2013071100026Floor Panel · cracked2S CHECK - CRACK ON FLOOR PANEL 151HF BETWEEN FR52 TO FR56 & BETWEEN Y970.8 TO Y1353. REPLACED FLOOR PANEL 151HF IAW SRM 53-02-00, PAR.8H, FIG 209 AND IRM 9701, REV G.SDR IPXA13579119Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 251XQF HAS DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA13579118Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 212XAF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA13579117Floorboard · damagedINSPECTION TYPE:C-8, MAIN CARGO FLOORBOARD 252XUF HAS DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA13579113Floor Panel · damagedINSPECTION TYPE:C8, MAIN CABIN FLOOR PANEL 242XFF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SERO B757-5320-9692-H.SDR IPXA13579112Floor Panel · damagedINSPECTION TYPE:C8, MAIN CABIN FLOOR PANEL 232XUF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13579110Floorboard · damagedINSPECTION TYPE:C8, MAIN CABIN FLOORBOARD 251XPF HAS DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA13579107Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 241XMF HAS DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692H.SDR IPXA3579081Floor Panel · delaminatedINSPECTION TYPE:C8 MAIN CABIN FLOOR PANEL 211XAF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA3579080Floor Panel · delaminatedINSPECTION TYPE:C8 MAIN CABIN FLOORBAORD 241XJF HAS DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.SDR IPXA3579068Floor Panel · delaminatedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 242XJF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692H.
Back to JASC 5321