What was found
2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR PANEL 261LG BETWEEN FR66 TO FR68, Y1732. REPLACED FLOOR PANEL 261LG IAW SRM 53-42-12, 51-42-11 & 51-73-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR PANEL 261LG BETWEEN FR66 TO FR68, Y1732. REPLACED FLOOR PANEL 261LG IAW SRM 53-42-12, 51-42-11 & 51-73-11.