JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3578057Floorboard · damagedINSPECTION TYPE:C-8, MAIN CARGO FLOORBOARD DELAMINATED, 241XHF FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578056Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CARGO FLOOR PANEL 232XWF, HAS A TORN & DELAMINATED CORNER. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578055Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CARGO FLOOR PANEL 232XXF, HAS A TORN CORNER AT INSERT LOCATION. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578029Floor Panel · damagedINSPECTION TYPE:C-8 MAIN CARGO FLOOR PANEL 252XKF DELAMINATED, FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578028Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CARGO FLOOR PANEL 242XKF, HAS EDGE DELAMINATION FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR UALA2013042902953Floor Panel · delaminatedFORWARD CARGO BAY FLOOR PANEL 131AF IS DELAMINATED AND HAS TOP SURFACE PERFORATION. REPLACED FLOOR PANEL IAW 53-22-14.SDR IPXA13578422Floorboard · delaminatedINSPECTION TYPE:C8S4, MAIN DECK FLOORBOARD 231XJF UPPER SURFACE IS DELAMINATED FROM CONTACT WITH BALLMAT. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR SWAA2013051516047Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222ABF DELAMINATED. REPAIRED PANEL IAW SRM.SDR SWAA2013051516045Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222AAF DELAMINATED. REMOVED AND REPLACED PANEL IAW SRM.SDR IPXA3578325Floorboard · brokenINSPECTION TYPE:C8S4, MAIN CARGO DECK FLOORBOARD 231XFF IS BROKEN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578324Floorboard · gougedINSPECTION TYPE:C8S4, MAIN CARGO DECK FLOORBOARD 232XJF GOUGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR SWAA2013051416015Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222AEF DELAMINATED. REMOVED AND REPLACED PANEL IAW SRM.SDR SWAA2013051416013Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221UF DELAMINATED. REMOVED AND REPLACED PANEL IAW SRM.SDR IPXA3578292Floor Panel · dentedINSPECTION TYPE:C8S4, FLOOR PANEL 221XCF DENTED AND GOUGED TOP AND BOTTOM SURFACES. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578286Floorboard · damagedMCD FLOORBOARD 232XEF HAS EDGED DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578213Floorboard · brokenINSPECTION TYPE:C8S4, MCD FLOORBOARD 241XJF HAS WRONG TYPE OF TAPE, BROKEN OUT INSERT AND CORROSION ON INSERTS. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9691-H.SDR IPXA13578212Floorboard · damagedINSPECTION TYPE:C8S4, MCD FLOORBOARD 242XSF HAS CORNER DAMAGE, WRONG TYPE OF TAPE AND A BROKEN OUT INSERT. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692.SDR IPXA13578186Floorboard · gougedINSPECTION TYPE:C8S4 MCD FLOORBOARD 222XCF IS GOUGED AND HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR SWAA2013050915878Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222JF DELAMINATED. REMOVED AND REPLACED PANEL IAW SRM.SDR DALA13019413211Floor Panel · corrodedDURING INSPECTION, FOUND FWD UTILITY FLOOR PANEL 231AF HAS CORROSION ON HINGE AND PANEL. REPLACED FLOOR PANEL.SDR IPXA3178087Floor Panel · puncturedINSPECTION TYPE:10YR, AFT CARGO COMPT FLOOR PANEL 152VF PUNCTURED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3178086Floor Panel · puncturedINSPECTION TYPE:10YR, AFT CARGO COMPT FLOOR PANEL 152KG PUNCTURED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3178085Floor Panel · puncturedINSPECTION TYPE:10YR, AFT CARGO COMPT FLOOR PANEL 152SF PUNCTURED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6 A.SDR IPXA3178084Floor Panel · puncturedINSPECTION TYPE:10YR, AFT CARGO COMPT FLOOR PANEL 152QF PUNCTURED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6 A.SDR IPXA3178083Floor Panel · puncturedINSPECTION TYPE:10YR, AFT CARGO COMPT FLOOR PANEL 152MG PUNCTURED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6 A.SDR IPXA3578059Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 232XYF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR DALA13020443135Floor Panel · damagedFWD CARGO FLOOR PANEL 132EG HAS MULTIPLE DENTS AND CRACKS. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13020433135Floor Panel · damagedFWD CARGO COMPT FLOOR PANEL 131CG HAS MULTIPLE DENTS AND EDGE DAMAGED. L=3" X W=1". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13020423135Floor Panel · dentedFWD CARGO FLOOR PANEL 131DG HAS MULTIPLE DENTS AND CRACKS. L=35" X W=12". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13020413135Floor Panel · damagedAFT CARGO FLOOR PANEL 161PF DAMAGED 3" X 3". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13020403135Floor Panel · damagedAFT CARGO FLOOR PANEL 151ZG DAMAGED 4" X 4". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR DALA13020353135Floor Panel · damagedAFT CARGO FLOOR PANEL 151PE DAMAGED 4" X 4". FABRICATED FLOOR PANEL IAW SRM 53-02-00 FIG 209, DWG 3D25-40532 AND INSTALLED.SDR C77A20130430015Finger Doubler · corrodedFORWARD CARGO DOOR THRESHOLD AFT FINGER DOUBLER,HAS CORROSION AT X=8400-8753 Y=300. R & R AFT FINGER DOUBLER IAW SRM 51-41-01 AND 51-43-01.SDR DALA13020173135Floor Panel · dentedFWD CARGO FLOOR PANEL 131EG HAS MULTIPLE DENTS AND CRACKS L=20" X W=12". FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40532.SDR USAA2013042900030Floor Panel · delaminatedC2 CHECK - DELAMINATION ON FLOOR PANEL 231KF BETWEEN FR24 & FR28, Z-500, Y=0. REPLACED FLOOR PANEL 231KF IAW IRM 9701 REV G.SDR USAA2013042900029Floor Panel · delaminatedC2 CHECK - DELAMINATION ON FLOOR PANEL 231QF BETWEEN FR28 & FR32, Z-500, Y=0. REPLACED FLOOR PANEL 231QF IAW IRM 9701 REV G.SDR AALA20130426014Strap · corrodedCORROSION ON CARGO FLOOR PANEL SPLICE STRAP. REPLACED SPLICE STRAP PER AARD 51-00-05-1.SDR IPXA3578329Floor Panel · puncturedINSPECTION TYPE:C8S4, MAIN DECK FLOOR PANEL PUNCTURED ON LOWER SURFACE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA3578328Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 231XMF HAS EGDE DAMAGE AND TORN NON-SKID. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR USAA2013051300025Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261PF BETWEEN FR68 TO FR70 & BETWEEN Y1292 TO -Y1292. REPLACED FLOOR PANEL 261PF IAW A320 SRM 53-02-00, PAR 8H, FIG 209 & IRM 9701 REV G.SDR USAA2013051300021Floor Panel · damaged2S CHECK - TOP LAYER MISSING FROM FLOOR PANEL 212CF BETWEEN FR5 TO FR7 & BETWEEN Y254 TO -Y254. REPLACED FLOOR PANEL 212CF IAW A320 SRM 53-12-00, PAR. 5F, FIG 206 & IRM 9701 REV G.SDR IPXA3578295Floorboard · puncturedINSPECTION TYPE: C8S4, FLOORBOARD 231XEF PUNCTURED AND HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578294Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 231XDF PUNCTURED AND HAS DAMAGED EDGES. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578290Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 221XAF GOUGED TOP & BOTTOM AND HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578289Floor Panel · puncturedINSPECTION TYPE:C8S4, MAIN DECK FLOOR PANEL 222XAF HAS PUNCTURE DAMAGE ON LOWER SURFACE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578288Floorboard · damagedINSPECTION TYPE:C8S4, MCD FLOORBOARD PN 143N5457-42 HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5 320-9692.SDR IPXA3578285Floor Panel · puncturedINSPECTION TYPE:C8S4 MAIN DECK FLOOR PANEL 251XEF HAS PUNCTURE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-HM.SDR IPXA3578283Floor Panel · delaminatedINSPECTION TYPE:C8S4, MAIN DECK FLOOR PANEL 232XHF UPPER SURFACE IS DELAMINATED FROM CONTACT WITH BALL MAT. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578281Floorboard · damagedINSPECTION TYPE:C8S4, MCD FLOORBOARD 252XEF UPPER SURFACE PUNCTURED, EDGES DAMAGED AND NON-SKID TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-H.SDR IPXA3578278Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 232XFF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.
Back to JASC 5321