SDR IPXA3578277Floor Panel · damagedINSPECTION TYPE:C8S4, MAIN DECK FLOOR PANEL 242XCF MISSING AN INSERT. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H,M.SDR IPXA3578275Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 231XHF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578274Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 242XMF HAS DAMAGED EDGES, WRONG TYPE OF TAPE AND CORROSION ON INSRTS. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578273Floorboard · brokenINSPECTION TYPE:C8S4, FLOORBOARD 232XDF HAS A BROKEN CORNER, EDGE DAMAGE, A BROKEN OUT INSERT AND THE NON-SKID IS PEELING. FABRICATED NEW FLOORBOARD IAW SREO 757-5320-9692-H.SDR IPXA13578234Floorboard · corrodedINSPECTION TYPE:C8S4 FLOORBOARD 242XAF HAS WRONG TAPE, CORROSION ON INSERTS AND NON-SKID TORN AND PEELING. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9592-H.SDR IPXA13578231Floorboard · gougedINSPECTION TYPE:C8S4, FLOORBOARD 221XBF, GOUGED TOP & BOTTOM AND EDGES DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-HM.SDR IPXA13578230Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 242XLF HAS EDGE DAMAGE, WRONG TYPE OF TAPE AND CORROSION ON ON THE INSERTS. FABRICATED NEW FLOORBOARD IAW IAW EO B757-5320-9692-HM.SDR IPXA13578228Floor Panel · dentedINSPECTION TYPE: C8S4, MAIN DECK FLOOR PANEL 252XLF DENTED AND GOUGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H M.SDR IPXA13578227Floor Panel · damagedINSPECTION TYPE:C8S4, MAIN DECK FLOOR PANEL 251XCF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-HM.SDR IPXA13578224Floor Panel · damagedINSPECTION TYPE:C8S4, MAIN DECK FLOOR PANEL 251XHF IS MISSING ONE INSERT. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H M.SDR IPXA13578223Floor Panel · damagedINSPECTION TYPE:C8S4, MAIN DECK FLOOR PANEL 241XMF HAS CORNER DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H M.SDR IPXA13578216Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 232XBF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578214Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 242XEF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578195Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 242XHF HAS BROKEN INSERTS AND DAMAGED EDGES. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13578194Floor Panel · damagedINSPECTION TYPE:C8S4, MAIN DECK FLOOR PANEL 251XAF HAS EDGES DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13578192Floorboard · brokenINSPECTION TYPE:C8S4, FLOORBOARD 252XDF HAS A BROKEN CORNER AND TORN NON-SKID. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13578190Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 242XXDF, EDGE DAMAGED AND MISSING INSERTS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13578189Floor Panel · damagedINSPECTION TYPE:C8S4, MAIN DECK FLOOR PANEL 251XBF AS CORNER DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA13578187Floor Panel · puncturedINSPECTION TYPE: C8S4, MAIN DECK FLOOR PANEL 222XBF HAS PUNCTURE DAMAGE ON UPPER AND LOWER SURFACE 53-105. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR USAA2013050800008Floor Panel · delaminated2S CHECK - CABIN FLOOR PANEL 261BG DELAMINATED. REMOVED AND REPLACED PANEL IAW A320 SRM 53-02-00 PAR 8H FIG 209 AND IRM 9701 REV G.SDR USAA2013050800007Floor Panel · cracked2S CHECK - CABIN FLOOR PANEL BETWEEN FR 42 & FR 47 FROM Y 1292 TO Y 1732 CRACKED. REMOVED AND REPLACED PANEL IAW IRM 9701 REV G AND A320 SRM 53-02-00 FIG 209.SDR ASAA2013042594693Floor Panel · damagedAFT CARGO FLOOR PANEL 140AF HAS ELONGATED HOLES. ACFT GROUNDED. FABRICATED FLOOR PANEL 140AF IAW DWG 453A2610-38, REV B.SDR USAA2013050700010Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 251JG BETWEEN FR62 TO FR64 & BETWEEN Y1732 TO Y1292. REPLACED FLOOR PANEL 251JG IAW A320 SRM 53-02-00, FIG 209 & IRM 9701 REV G.SDR SWAA2013050215478Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222 ABF DELAMINATED. REPAIRED PANEL IAW SRM.SDR SWAA2013050215477Floor Panel · delaminatedMAIN CABIN FLOOR PANEL DELAMINATED PANEL 222 AAF. REPAIRED PANEL IAW SRM.SDR DALA13019393211Floor Panel · corrodedDURING INSPECTION, FOUND FWD CABIN FLOOR PANEL 222FF HAS CORROSION. REPLACED FLOOR PANEL IAW SRM 51-72-11.SDR DALA13019363211Floor Panel · damagedDURING INSPECTION, FOUND FWD CABIN FLOOR PANEL 232DF HAS TWO BAD INSERTS. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13019353211Floor Panel · puncturedDURING INSPECTION, FOUND FWD CABIN FLOOR PANEL 221AF HAS PUNCTURED 1" X 1". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13019343211Floor Panel · corrodedDURING INSPECTION, FOUND FLOOR PANEL 261FF HAS LIGHT CORROSION. REMOVED CORROSION IAW SRM 51-74-00, REPLACED FLOOR PANEL, IAW SRM 51-72-11.SDR DALA13019333211Floor Panel · corrodedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 152KF CORROSION ON LOWER SIDE. DAMAGE DIA L=6" X W=18" NO ALLOWABLE LIMIT ON SRM, REPLACED AFT CARGO FLOOR PANEL IAW SRM 51-72-11.SDR DALA13019253135Floor Panel · puncturedCENTER CABIN FLOOR PANEL 242BF PUNCTURED 0.30 IN DIAMETER. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13019243135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241JF DELAMINATED L=7.0" X W=5.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13019233135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241LF DELAMINATED L=8.0" X W=2.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13019223135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241BF DELAMINATED L=20.0 X W=12.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13019213135Floor Panel · delaminatedFWD UTILITY FLOOR PANEL 231NF DELAMINATED L=10.0" X W=6.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13019203135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241FF DELAMINATED L=36.0 X W=1.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13019193135Floor Panel · delaminatedFWD UTILITY FLOOR PANEL 231ZG, DELAMINATED L=6.5" W=5". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13019183135Floor Panel · delaminatedFWD UTILITY FLOOR PANEL 231XG DELAMINATED L=3.0 X W=1.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13019103135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241EF, DELAMINATED L=6.0" X W=1-0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640. NO ESTABLISH LIMITS IAW SRM 53-02-00.SDR IPXA3578327Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 252XTF HAS EDGES TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578326Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 251XQF BOTTOM SIDE IS CRUSHED AND EDGES TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578298Floorboard · damagedINSPECTION TYPE:C8S4 FLOORBOARD 232XTF BOTTOM SIDE AND EDGES HAS DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578296Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 232XVF EDGES TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578293Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 252XRF BOTTOM SIDE AN EDGES HAS DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578287Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 232XUF EDGE IS CRUSHED AND TORN AROUND THE PANEL. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578284Floorboard · damagedINSPECTION TYPE:C8S4 FLOORBOARD 251XPF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578282Floorboard · crushedINSPECTION TYPE:C8S4, FLOORBOARD 252XQF TOP AND BOTTOM SURFACES HAS CRUSHED DAMAGE, INSERTS CORRODED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578280Floorboard · delaminatedINSPECTION TYPE:C8S4, FLOORBOARD 231XRF HAS PANEL EDGES TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578279Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 252XSF HAS EDGES TORN AND INSERT MISSING. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3578276Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 251XNF IS DAMAGED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.
Back to JASC 5321