JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA13578235Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 251XFF HAS EDGES TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578233Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 232XYF HAS ALL EDGES TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578232Floorboard · crushedINSPECTION TYPE:C8S4, FLOORBOARD 232XQF BOTTOM SIDE HAS NUMEROUS CRUSHED DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-HM.SDR IPXA13578229Floorboard · damagedINSPECTION TYPE: C8S4, FLOORBOARD 242XKF CORNER AND EDGES TORN. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13578226Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 241XKF ALL EDGES TORN. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-HM.SDR IPXA13578225Floorboard · crushedINSPECTION TYPE:C8S4, FLOORBOARD 251XJF, BOTTOM SIDE HAS CRUSH DAMAGE AND INSERT LOOSE. FABRICATED NEW FLOORBOARD IAW EO B757-5326-9692-HM.SDR IPXA13578222Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 241XHF INSERT HOLE AND EDGE TORN. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13578220Floorboard · debondedINSPECTION TYPE:C8S4, FLOORBOARD 242XBF EDGE DISBONDED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13578217Floorboard · damagedINSPECTION TYPE:C8S4, FLOORBOARD 252XHF, ALL EDGES TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578215Floorboard · damagedINSPECTION TYPE: C8S4, FLOORBOARD 241XEF ALL EDGES TORN AND BOTTOM SIDE CRUSHED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578211Floorboard · crushedINSPECTION TYPE:C8S4, FLOORBOARD 231XSF EDGES CRUSHED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-HM.SDR IPXA13578193Floorboard · brokenINSPECTION TYPE:C8S4, FLOORBOARD 241XAF PANEL EDGES IS BROKEN. FABRICATED NEW FLOORBOARD IAW IAW EO B757-5320-9692-HM.SDR IPXA13578191Floorboard · crushedINSPECTION TYPE:C8S4, FLOORBOARD 241XBF BOTTOM SIDE CRUSHED, FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13578188Floorboard · debondedINSPECTION TYPE:C8S4, FLOORBOARD 232XRF EDGES DEBONDED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA13578185Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 231XNF HAS EDGES TORN, FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR ASAA2013042494644Floor Support · damagedAFT CARGO UNDER FLOOR SUPPORT ANGLE HAS ELONGATED BOLT HOLE, RBL 13.5, BETWEEN BS 727B AND 727C. REPAIRED AFT CARGO FLOOR SUPPORT.SDR IPXA3578054Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 231XEF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR USAA2013042500025Floor Panel · crackedC2 CHECK - CRACK ON FLOOR PANEL 232DF BETWEEN FR20 TO FR24, -Y765. REPLACED FLOOR PANEL 232DF IAW IRM 9701 REV G.SDR DALA13018683135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 251LF DELAMINATED L=42.0" X W=1.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D2540640.SDR DALA13018673135Floor Panel · delaminatedFWD UTILITY FLOOR PANEL 232AH DELAMINATED L=12.0" X W=6.0". FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 AND DWG 3D2540640.SDR DALA13018663135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 251MF DELAMINATED L=6.0" X W=1.0". FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR DALA13018653135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 242FF DELAMINATED L=14.0" X W=3.0". FLOOR PANEL FABRICATED NEW IAW SRM 53-02-00, FIG 209 AND DWG 3D25-40640.SDR IPXA3578291Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 232XWF HAS ALL EDGES TORN. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13578221Floorboard · tornINSPECTION TYPE:C8S4, FLOORBOARD 241XDF HAS ALL EDGES TORN AND TOP SIDE CRUSHED. FABRICATED NEW FLOORBOARD IAW EOB757-5320-9692-H.SDR IPXA13578218Floorboard · damagedINSPECTION TYPE: C8S4, FLOORBOARD 231XWF HAS ALL EDGES TORN AND DELAMINATED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-4 -H.SDR SWAA2013050715694Floor Panel · corrodedFLOOR PANEL CORRODED AT STA 431, RBL 44.5. REMOVED AND REPLACED PANEL IAW SRM.SDR ASAA2013042394643Floor Panel · corrodedFWD CARGO FLOOR PANEL 120DF IS CORRODED ON EDGES. FABRICATED NEW FLOOR PANELSDR IPXA3178070Floor Panel · delaminatedINSPECTION TYPE:10YR, MAIN DECK CARGO FLOOR PANEL 242BF HAS LOWER SKIN TORN AND DELAMINATED. FABRICATED FLOOR PANEL IAW EO A300-5320-40552-B APPENDIX B.SDR IPXA13577972Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 222XAF HAS DAMAGE ON BOTTOM SURFACE. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577962Floorboard · damagedINSPECTION TYPE:C-8 MAIN CABIN FLOORBOARD 231XWF HAS DAMAGE ON FWD EDGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577961Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 221XCF HAS DAMAGE ON BOTTOM SURFACE FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577960Floor Panel · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOOR PANEL 222XBF HAS DAMAGE ON BOTTOM SIDE FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA13577959Floorboard · damagedINSPECTION TYPE:C-8 MAIN CABIN FLOORBOARD 222 XAF HAS DAMAGE ON BOTTOM SURFACE FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA13577958Floorboard · damagedINSPECTION TYPE:C-8, MAIN CABIN FLOORBOARD 222XCF HAD DAMAGE ON BOTTOM SURFACE FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR DALA13018553135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241CF DELAMINATED L=14.0' X W=8.0". FABRICATED NEW FLOOR PANEL IAW DWG 3D25-40640 AND SRM 53-02-00, FIG 209.SDR DALA13018543135Floor Panel · puncturedCENTER CABIN FLOOR PANEL 251NF PUNCTURED & DELAMINATED L=10.0" X W=10.0". FABRICATED NEW FLOOR PANEL IAW DWG 3D25-40640 AND SRM 53-02-00, FIG 209.SDR DALA13018533135Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241GF DELAMINATED L=20.0" X 10.0". FABRICATED NEW FLOOR PANEL IAW DWG 3D25-40640 AND SRM 53-02-00, FIG 209.SDR DALA13018523135Floor Panel · puncturedCENTER CABIN FLOOR PANEL 251GF PUNCTURED & DELAMINATED L=10.0" X W=12.0". FABRICATED NEW FLOOR PANEL IAW DWG 3D25-40640 AND SRM 53-02-00, FIG 209.SDR DALA13018493135Floor Support · corrodedMAIN CABIN LT AFT FLOOR SUPPORT BET FR66 & FR68 +Y1292 HAS CORROSION. BLENDED CORRODED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND TRM 53-21-01.SDR DALA13018483135Floor Support · corrodedMAIN CABIN FLOOR SUPPORT FR68 TO FR69 +Y1292 HAS CORROSION AROUND FASTENER HOLE. BLENDED CORRODED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND TRM 53-21-01.SDR UALA2013042302830Floor Panel · damagedAFT PIT FLOOR HAS A HOLE AT STA 1480 DIA 1 X1 AND A HOLE AT STA 1500 DIA 2X2. REPAIRED HOLES IAW SRM 53-00-53, PG 103-104, FIG 101.SDR IPXA3178072Floor Panel · crackedINSPECTION TYPE:10YR, FLOOR PANEL 241VM CRACKED. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B, APPENDIX B.SDR DALA13018453135Floor Panel · damagedAFT UTILITY FLOOR PANEL 262EF DAMAGED 4" X 4". FABRICATED FLOOR PANEL IAW DWG 3D25-40640 AND SRM 53-02-00, FIG 209.SDR DALA13018443135Floor Panel · damagedAFT UTILITY FLOOR PANEL 261PF DAMAGED 2.5" X 2.5". FABRICATED FLOOR PANEL IAW DWG 3D25-40640 AND SRM 53-02-00, FIG 209.SDR DALA13018433135Floor Panel · damagedAFT UTILITY FLOOR PANEL 262HG DAMAGED 3" X 3". FABRICATED FLOOR PANEL IAW DWG 3D25-40640 AND SRM 53-02-00, FIG 209.SDR USAA2013051300024Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 151DF BETWEEN FR50 TO FR53 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL 151DF IAW A320 SRM 53-02-00, FIGURE 209 & IRM 9701 REV G.SDR USAA2013051300023Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 151AF BETWEEN FR46 TO FR50 & BETWEEN Y765 TO -Y765. REPLACED FLOOR PANEL 151AF IAW A320 SRM 53-02-00, FIGURE 209 & IRM 9701 REV G.SDR USAA2013051300022Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 131JF BETWEEN FR38 TO FR34 & BETWEEN Y765 TO Y970.8. REPLACED FLOOR PANEL 131JF IAW A320 SRM 53-02-00 FIGURE 209 & IRM 9701 REV G.SDR IPXA3178071Floor Panel · tornINSPECTION TYPE:10YR, MAIN DECK CARGO FLOOR PANEL 241HN LOWER SKIN TORN. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA13177928Floor Panel · damagedHOLE IN FLOOR PANEL, POS 11L. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-16407-E.
Back to JASC 5321