JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3177760Floorboard · damagedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 241WK HAS LOWER SKIN TORN. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR FDEA201303210635Floor Panel · corrodedFWD CARGO FLOOR PANEL 131QF BACK SIDE HAS APPROX 60 SQUARE INCHES OF CORROSION EXTENDING UNDER METAL FOIL COVERING. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG. SRZ-25-005 REV J.SDR FDEA201303210634Floor Panel · inoperativeFWD CARGO FLOOR PANEL 131YF HAS BROKE OUT FILLER AT FASTENER HOLE AND SIX PUNCTURES ON BACK SIDE. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ-25-005 REV J.SDR USAA2013042200012Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 262BG BETWEEN FR64 TO FR66 & BETWEEN -Y765 TO -Y1732. REPLACED FLOOR PANEL 262BG IAW A321 SRM 53-02-00, IRM 9701 REV G & EA 503992.SDR USAA2013041600024Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 261PF BETWEEN FR68 TO FR70 & BETWEEN -Y1292 TO Y1292. REPLACED FLOOR PANEL 261PF IAW A321 SRM 53-02-00, FIGURE 209 & IRM 9701 REV G.SDR SWAA2013041014715Floor Panel · corrodedFLOOR PANEL 222EF CORRODED. REMOVED AND REPLACED FLOOR PANEL 223EF IAW SRM.SDR SWAA2013041014714Floor Panel · corrodedFLOOR PANEL 221XF CORRODED. REMOVED AND REPLACED FLOOR PANEL IAW SRM.SDR SWAA2013041014713Floor Panel · corrodedFLOOR PANEL 222ADF CORRODED. REMOVED AND REPLACED FLOOR PANEL IAW SRM.SDR IPXA3577648Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 241XHF HAS DAMAGED CORNER. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577647Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 241XFF HAS EDGE AND CORNER DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577645Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 242XDF HAS DAMAGED CORNER. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577644Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 241XJF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577638Floorboard · damagedINSPECTION TYPE:S2C1, MAIN DECK FLOORBOARD 242XEF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SAMPLE IAW EO B757-5320-96 92-H.SDR SWAA2013032614105Floor Panel · delaminatedFLOOR PANEL 241AEF DELAMINATED. REPAIRED PANEL IAW SRM.SDR FDEA201303200627Floor Panel · damagedFWD CARGO FLOOR PANEL 132QF INNER SURFACE HAS SIX PUNCTURES. FABRICATED REPLACEMENT PANEL 132QF IAW DWG SR2 25-005, REV J.SDR DALA13012773134Floor Panel · damagedAFT CARGO SLOPE PANEL 162BF PUNCTURED. FABRICATED NEW PANEL ON DWG 3D25-40532.SDR DALA13012765654Floor Panel · dentedCOCKPIT FLOOR DENTED AND GOUGED UNDERNEATH TIE-DOWN LUG, APPROX BS 288 RBL4 CORRODED. REPAIRED IAW ER/A 511576-14, REV ORIGINAL.SDR FDEA201303200632Floorboard · delaminatedAFT CARGO FLOORBOARD 161AF SKIN DELAMINATED BY 3 FT X .5 FT ON 1 CORNER AND 10 X 2" ON OPPOSITE CORNER. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-011, REV E, DWG SRZ 25-005, REV J.SDR FDEA201303200631Floorboard · damagedON REMOVAL OF FLOORBOARD 242FK TO ACCESS MAINTENANCE REPAIR PER N/R 00300. FOUND FLOORBOARD LOWER SKIN TORN BY 1 1/2 X 1 1/2 INCH. FABRICATED REPLACEMENT FLOORBOARDIAW DWG SRZ 25-005 REV JSDR FDEA201303200630Floor Panel · damagedAFT CARGO FLOOR PANEL 162HF HAS A CRACK HOLE PUNCH MEASURES 1.2500" AND 1 HOLE PUNCH IMPACT 1 INCH AND EDGE SKIN TORN BY 4 INCH AND SEVERAL SMALL HOLE PUNCHES FABRICATED. REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-011, REV E AND SRZ 25-005, REV J.SDR FDEA201303200629Floor Panel · damagedAFT CARGO FLOOR PANEL 161 GF HAS A CUT OF 2", IMPACT CUT 2.5", SKIN CUT .7500. IMPACT DENT MEASURES 2 X 2" IN UPPER SKIN SURFACE. FABRICATED FLOOR PANEL IAW DWG SRZ 25-005, REV J AND SRZ 25-011, REV E.SDR FDEA201303200628Floor Panel · crackedMAIN DECK CARGO FLOOR PANEL 241WH IS CRACKED ACCROSS ITS WIDTH. FABRICATED FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR DALA13012705635Deck Plate · corrodedAFT DECK PLATE UPPER SURFACE FOUND CORRODED AT BS 1712-1715, LBL 09 TO 15. CORROSION REMOVED IAW SRM 51-10-02. ULTRASONIC INSPECTION CARRIED OUT IAW NDTM D634N301, REV 101.00 PART 4 51-00-10. FOUND OUT OF LIMITS IAW SRM 53-60-51, FIG 201, REPAIR 2. REPAIRSDR DALA13012695635Deck Plate · corrodedAFT DECK PLATE UPPER SURFACE FOUND CORRODED AT BS 1712.5-1715 LBL 15.5 TO LBL 20. CORROSION REMOVED IAW SRM 51-10-02. ULTRASONIC INSPECTION CARRIED OUT IAW NDTM D634N301, REV 101.00 PART 4 51-00-10. FOUND OUT OF LIMITS IAW SRM 53-60-51, FIG 201, REPAIR 2. RSDR DALA13012685635Deck Plate · corrodedDECK PLATE UPPER SURFACE FOUND CORRODED AT BS 1708, BL 0. CORROSION REMOVED IAW SRM 51-10-02. ULTRASONIC INSPECTION CARRIED OUT IAW NDTM 0634N301, REV 101.00, PART 4 51-00-10. FOUND FOUND OUT OF LIMITS IAW SRM 53-60-51, FIG 201, REPAIR 2.SDR ASAA2013031994582Floorboard · gougedFWD CARGO FLOORBOARD HAS SEVERAL DEEP GOUGES. FABRICATED NEW FLOORBOARD IAW SRM 51-40-05.SDR USAA2013042200014Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL 151GF BETWEEN FR52 TO FR56 & BETWEEN -Y765 TO Y765. REPLACED FLOOR PANEL 151GFF IAW A321 SRM 53-02-00, PAR 8H, FIGURE 209 & IRM 9701 REV G.SDR ASAA2013031994501Floorboard · gougedAFT CARGO NR 2 FLOORBOARD HAS DEEP GOUGES. FABRICATED, LOCATED AND DRILLED NEW FLOORBOARD IAW SRM 51-40-05.SDR ASAA2013031994491Floorboard · gougedAFT CARGO NR 4 FLOORBOARD HAS EXISTING LINE REPAIR AND SEVERAL DEEP GOUGES. FABRICATED, LOCATED AND DRILLER NEW FLOORBOARD IAW SRM 51-40-05 AND 51-20-01 AND SOPM 20-41-02.SDR ASAA2013031994444Floorboard · gougedAFT CARGO NR 3 FLOORBOARD HAS SEVERAL DEEP GOUGES. FABRICATED NEW FLOORBOARD IAW SRM 51 40 05.SDR ASAA2013031994443Floorboard · damagedFWD CARGO NR 1 FLOORBOARD DAMAGED. FABRICATED, LOCATED AND DRILLER NEW FLOORBOARD IAW SRM 51 40 05 06 P, FIG 9, TABLE 5.SDR ASAA2013031994351Floorboard · corrodedAFT CARGO NR 2 FLOORBOARD SPLICE IS CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS, FABRICATED NEW SPLICE IAW SRM 51-30-01, STEP 8AB.SDR IPXA3177699Floorboard · damagedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 232WG HAS EDGE DAMAGED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA3177697Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 231NJ HAS LOWER SKIN CRACKED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA3177685Floor Panel · puncturedINSPECTION TYPE:10YR, FLOOR PANEL 262AM PUNCTURED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177677Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 242BJ LOWER SKIN IS CRACKED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177676Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 242RM HAS LOWER SKIN TORN AND DELAMINATED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D PARA 6A.SDR IPXA3177675Floorboard · damagedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 222NG HAS DAMAGED INSERTS. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA3177674Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 242LJ IS CRACKED AT UPPER FWD CORNER. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA3177673Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 242LH IS CRACKED AT LOWER SURFACE. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR SWAA2013032814188Floorboard · delaminatedFLOORBOARD 242RF FWD I/B CORNER DELAMINATED. REPAIRED FLOORBOARD IAW SRM.SDR IPXA3577643Floorboard · damagedINSPECTION TYPE:S2C1 FLOORBOARD 242XCF EDGES DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577642Floorboard · damagedINSPECTION TYPE:S2C1, FLOORBOARD 242XAF EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577641Floorboard · damagedINSPECTION TYPE:S2C1, FLOORBOARD 241XAF EDGE DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577640Floorboard · damagedINSPECTION TYPE:S2C1, FLOORBOARD 242XJF EDGE DAMAGED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA3577639Floorboard · damagedINSPECTION TYPE:S2C1, FLOORBOARD 242XFF HAS ONE MISDRILLED HOLE AND EDGE DAMAGED. FABRICATED NEW FLOORBOARD IAW SAMPLE IAW EO B757-5320-9692-H.SDR IPXA3177661Floor Panel · crackedINSPECTION TYPE:10YR, MDCC FLOOR PANEL 231PH CRACKED & PUNCTURED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177659Floor Panel · tornINSPECTION TYPE:10YR, FLOOR PANEL 222AG HAS LOWER SKIN TORN AND CORRODED INSERTS. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177657Floor Panel · delaminatedINSPECTION TYPE:10YR, MDCC FLOOR PANEL 232JF DELAMINATED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D6A.SDR IPXA3177656Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 231AH HAS LOWER SKIN DELAMINATED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.
Back to JASC 5321