JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3177655Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 231KG HAS LOWER SKIN DELAMINATED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177653Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 241RN HAS LOWER SKIN CRACKED FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA3177652Floorboard · damagedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 232KH HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA3177651Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 231LG HAS LOWER SKIN CRACKED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR SWAA2013032614104Floorboard · brokenFLOORBOARD 221GF FWD OUTBOARD CORNER BROKEN. FLOORBOARD IAW SRM.SDR IPXA3177620Floorboard · puncturedINSPECTION TYPE: 10 YR, MAIN CABIN FLOORBOARD 231QJ HAS LOWER SKIN PUNCTURED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177619Floorboard · puncturedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 232LF HAS LOWER SKIN PUNCTURED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177617Floorboard · damagedINSPECTION TYPE: 10 YR, MAIN CABIN FLOORBOARD 241TN LOWER SKIN IS TORN. REPAIRED FLOORBOARD 241TN IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177616Floorboard · puncturedINSPECTION TYPE: 10 YR, MAIN CABIN FLOORBOARD 231SG LOWER SKIN IS PUNCTURED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177615Floorboard · crackedINSPECTION TYPE: 10 YR, MAIN CABIN FLOORBOARD 232NJ HAS LOWER SKIN CRACKED. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR DALA13012643134Floorboard · damagedAFT CARGO BAY FLOORBOARD 161NF DAMAGED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012633134Floorboard · delaminatedAFT CARGO BAY FLOORBOARD 151PE DELAMINATED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012623134Floorboard · damagedAFT CARGO BAY FLOORBOARD 151CE DAMAGED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012613134Floorboard · delaminatedAFT CARGO BAY FLOORBOARD 151VG DELAMINATED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012603134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151UG DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012593134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152WG DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012583134Floor Panel · puncturedAFT CARGO BAY SLOPE PANEL 162FF, HAS PUNCTURE DAMAGE. FABRICATED SLOPE PANEL IAW SRM 53-02-00 FIG 209.SDR DALA13012573134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151AE DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012553134Floorboard · damagedAFT CARGO BAY FLOORBOARD 161PF DAMAGED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012543134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152XG DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012533134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151FE DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012523134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151DE DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012513134Floorboard · delaminatedAFT CARGO BAY FLOORBOARD 151ZG DELAMINATED. FABRICATED NEW FLOORBOARD.SDR DALA13012503134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152TG DAMAGED. FABRICATED NEW SLOPE PANEL.SDR DALA13012493134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151TG DAMAGED. FABRICATED NEW SLOPE PANEL.SDR FDEA201303190614Floorboard · damagedFLOORBOARD 24GK , INBD FWD CORNER IS BROKEN OFF. FABRICATED FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201303190613Floorboard · crackedFLOORBOARD 242VH IS CRACKED ALL THE WAY ACCROSS. FABRICATED FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201303190612Floorboard · damagedFLOORBOARD 241RJ IS BROKEN IN TWO. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005 REV J.SDR FDEA201303190611Floorboard · crackedMAIN DECK CARGO FLOORBOARD 242ZJ HAS APPROX A 10 INCH CRACK. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201303190610Bulkhead · crackedRIGHT W/W HAS A 1 INCH CRACK INNER WALL 30 INCHES FORWARD OF BS 1521 & 2 FEET DOWN. REPAIR WAS ACCOMPLISHED AND INSTALLED REF EA 8-5310-157386, SEQ NR 255. EA 8-5310-157386 FINAL DRAFT SEQ 257 OF WO 58015 FOR MX PERFORMED.SDR UALA2013031901692Floorboard · dentedAFT CARGO BAY ONE FOOT FWD OR CARGO DOOR, FOUR INCH DENT IN FLOORBOARD. REPAIRED IAW SRM 53-02-00.SDR ASAA2013031894330Floor Panel · corrodedAFT CARGO BAY BS 945 AFT FLOOR PANEL HAS CORROSION ON AFT RT END. REMOVED, FABRICATED NEW AND INSTALLED NEW FLOOR PANEL IAW AMM 25-52-51-004-001, PARA C, 25-52-51-404-011 PARA D, SRM 51-40-05, FIG 2, DETAIL I, 51-20-01 PARA G AND SOPM 20-41-02, PARA 6F. FOUNSDR DALA1308093746Floor Panel · corrodedFWD CARGO FLOOR PANEL 120DF HAS SEVERAL AREAS OF CORROSION AROUND EDGE OF PANEL. CORROSION OUT OF LIMITS. FABRICATED NEW FLOOR PANEL IAW DWG 453A-1600 AND SRM 53-60-53 TABLE 2, ITEM 1.SDR IPXA3577752Floorboard · debondedINSPECTION TYPE:C16, MAIN CABIN FLOORBOARD 242XMF AFT CORNER IS DISBONDED. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H8.SDR IPXA3177698Floorboard · damagedINSPECTION TYPE:10YR MAIN CABIN FLOORBOARD 241SK HAS EDGE & CORE DAMAGE. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA3177691Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 241LJ IS CRACKED ON LOWER SURFACE REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177684Floor Panel · crackedINSPECTION TYPE:10YR, FLOOR PANEL 241LT CRACKED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6 A.SDR IPXA3577663Floor Panel · delaminatedINSPECTION TYPE:C-10, MAIN CABIN DECK FLOOR PANEL 242XJF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3577662Floor Panel · delaminatedINSPECTION TYPE:C-10, MAIN CABIN DECK FLOOR PANEL 241XFF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR ASAA2013031894229Floor Panel · corrodedAFT CARGO NR 2 FLOOR PANEL HAS CORROSION. FABRICATED NEW FLOOR PANEL IAW SRM 51-40-05, FIG 2, DETAIL I, 51 20 01 PARA 6 AND SOPM 20 41 02, PARA 6.F. REMOVED CORRODED ON NR 2 FLOOR PANEL AND FOUND TO BE OUT OF LIMITS IAW SRM 53 60 53, FIG 19 DETAIL V.SDR IPXA3177618Floorboard · damagedINSPECTION TYPE: 10 YR, MAIN CABIN FLOORBOARD 241EF HAS 4 DAMAGED AREAS ON UPPER AND LOWER SKIN. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR USAA2013031900006Floorboard · delaminated2S CHECK - DELAMINATED FLOORBOARD 231FF BETWEEN FR20 TO FR24, Z-500, Y1037. REPLACED FLOORBOARD 231FF IAW IRM 9701 REV G.SDR SWAA2013041014659Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222AHF DELAMINATED. REMOVED AND REPLACED PANEL IAW SRM.SDR SWAA2013041014658Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222ABF DELAMINATED. REMOVED AND REPLACED PANEL IAW B717 SRM.SDR SWAA2013041014657Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 222AGF DELAMINATED. REMOVED AND REPLACED PANEL IAW SRM AND AMM.SDR SWIA201333151Floor Panel · crackedELECTRICAL FLOOR PANEL CRACKED AT FS 193.0-LBL 31.0. (C-CHECK) INSTALLED REPAIR DOUBLER ON ELECTRICAL FLOOR PANEL AT FS 193.0 LBL 31.0 IAW SRM AND REO.SDR IPXA3177716Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 241ZH HAS LOWER SKIN CRACKED. FABRICATED FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA3177690Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 242MN IS CRACKED AT LOWER SURFACE. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177689Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 241SH IS CRACKED AT LOWER SURFACE. REPAIRED FLOORBOARD IAW EO A300-5320-42721-D, PARA 6A.SDR IPXA3177660Floor Panel · puncturedINSPECTION TYPE:10YR MDCC FLOOR PANEL 241YH PUNCTURED & CRACKED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-D, PARA 6 A.
Back to JASC 5321