JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA12574729Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD NR 241XMF HAS DAMAGED INSERTS. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574723Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD 251XMF HAS SKIN DAMAGE. FABRICATED FLOORBOARD IAW EO 757-5320-9692-H.SDR IPXA12574722Floorboard · damagedINSPECTION TYPE:C, FLOORBOARD NR 251XFF HAS SKIN DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12574720Floor Panel · damagedINSPECTION TYPE:C, RT SIDE FLOOR PANEL 252XSF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574719Floor Panel · damagedINSPECTION TYPE: C, LT SIDE FLOOR PANEL 252XTF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574717Floor Panel · puncturedINSPECTION TYPE: C, BS 1320, LT FLOOR PANEL 251XEF HAS PUNCTURE IN UPPER SKIN SURFACE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574716Floor Panel · damagedINSPECTION TYPE:C, BS 1200, LT FLOOR PANEL 251XBF HAS EDGE. CORNER DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574715Floor Panel · damagedINSPECTION TYPE:C, BS 1600, LT FLOOR PANEL 251XNF HAS EDGE/CORNER DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574713Floor Panel · crackedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251AF CRACKED IN THE MIDDLE OF PANEL. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574712Floor Panel · damagedINSPECTION TYPE:C, BS 1320 LT FLOOR PANEL 251XDF HAS PULLED INSERTS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574711Floorboard · damagedINSPECTION TYPE:C-CK, RT SIDE FLOORBOARD 252XQF HAS MISSING INSERTS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574677Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 231XHF DAMAGED AND REQUIRES FABRICATION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR FDEA201207312791Floorboard · damagedFLOORBOARD 232UG HAS MISSING EDGE FILLER ON AFT EDGE (3 INCHES) AND AROUND CLEVIS CUTOUT (10 INCHES) ALSO SMALL PUNCTURED AREA LOCATED 0.5 INCH FROM AFT EDGE. FABRICATED FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207312790Floorboard · crackedMAIN CARGO DECK FLOORBOARD 231FF CRACKED AND HAS FOUR LOOSE INSERTS AND 30 INCHES OF EDGE FILLER MISSING. FABRICATED FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207312789Floorboard · damagedAFT CARGO FLOORBOARD 161AF BACKING SEPARATED AND CORRODED APPROX 10 SQUARE INCHES. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207312788Floorboard · damagedBULK CARGO FLOORBOARD 161GF, BACKING HAS SEPARATED IN SEVERAL PLACES. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207312787Floorboard · puncturedFLOORBOARD 231VG, HAS A .75 PUNCTURE AT UPPER SURFACE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207312786Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL 231HG HAS TEN INCHES OF EDGE FILLER MISSING AND FWD CORNER BROKEN OFF. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR ASOA2012082102086Floor Panel · crackedFWD EQUIPMENT COMPARTMENT FLOOR PANEL CRACKED RT SIDE FS 193.00, WL 79.50. REPLACED IAW EC/TC REO 670-53-11-509.SDR ASOA2012082102085Floor Panel · crackedFWD EQUIPMENT COMPARTMENT FLOOR PANEL CRACKED LT SIDE. REPAIRED IAW EC/TC REO 670-53-11-509.SDR UALA2012073104123Floor Panel · puncturedTWO PUNCTURES IN AFT CARGO BAY FLOOR PANEL AT STA 1402. FIRST HOLE 4X5 AND SECOND HOLE 2.5 X .5. REPAIRED DAMAGED FLOOR PANEL PER MM 53-30-98 REPAIR 4.DSDR IPXA12674816Floorboard · puncturedINSPECTION TYPE:9C, MAIN CARGO 4L, BS 540-654+22, L33 TO L55, HAS PUNCTURED FLOORBOARD. FLOORBOARD FABRICATED IAW EO B767-5320-9693H AND INSTALLED IAW AMM 53-01-06.SDR IPXA12574724Floorboard · delaminatedINSPECTION TYPE:C, FLOORBOARD 212XAF HAS DELAMINATION. FABRICATED FLOORBOARD IAW EO 757-5320-9692-H.SDR IPXA12574714Floor Panel · delaminatedINSPECTION TYPE:C-CK, FLIGHT DECK FLOOR PANEL 211XAF HAS DELAMINATION AND EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2174699Floorboard · crackedINSPECTION TYPE:SV, MAIN CABIN FLOORBOARD 231MJ HAS UPPER SKIN PUNCTURED AND LOWER SKIN CRACKED. ACCOMPLISHED REPAIR ON FLOORBOARD IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA2174698Floorboard · delaminatedINSPECTION TYPE:SV, MAIN CABIN FLOORBOARD 222DG HAS LOWER SKIN TORN AND DELAMINATED. ACCOMPLISHED REPAIR ON FLOORBOARD IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA2174697Floorboard · puncturedINSPECTION TYPE:SV, MAIN CABIN FLOORBOARD NR 231TG UPPER AND LOWER SKIN IS PUNCTURED. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 231TG IAW EO A300-5320-42721-B, PARA 6A.SDR IPXA2174696Floorboard · crackedINSPECTION TYPE:SV, MAIN CABIN FLOORBOARD NR 231RG HAS UPPER SKIN PUNCTURED AND LOWER SKIN CRACKED. ACCOMPLISHED REPAIR ON FLOORBOARD IAW EO A300-5320-42722-B, PARA 6A AND EO A300-5320-42721-B, PARA 6A.SDR IPXA2574666Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO BAY FLOORBOARD 242XDF HAS SEVERAL INSERTS DAMAGED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR FDEA201207302767Floorboard · damagedMAIN DECK CARGO FLOORBOARD 241DF HAS SEVEN INCHES OF IMPACT DAMAGE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207302765Floorboard · crackedFLOORBOARD 232VH, BROKEN ACROSS ENTIRE MIDDLE SECTION. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207302764Floor Panel · damagedMAIN DECK CARGO FLOOR PANEL 231AH HAS ONE INSERT PULLED THRU PANEL & 10 INCHES OF EDGE FILLER MISSING. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201207302763Floorboard · damagedMAIN DECK CARGO FLOORBOARD 242QJ CRUSHED AROUND THE CLEVIS ADAPTER CUT OUT AT THE EDGE, FOUR PLACES. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV. JSDR FDEA201207302762Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL 241YJ HAS CORNER BROKEN OFF APPROXIMATELY FOUR SQUARE INCHES. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR IPXA12M74968Floor Panel · brokenINSPECTION TYPE: 4C, FLOOR PANEL 261FF HAS BROKEN INSERTS. FABRICATED FLOOR PANEL REF EO MD11-5320-27386-C, APPX A/B.SDR DALA12004743131Floorboard · crackedAFT CARGO FLOORBOARD 161NF IS DELAMINATED AND CRACKED. FABRICATED NEW FLOORBOARD IAW DWG 3D25-40532.SDR FDEA201207282738Floor Panel · crackedFLOOR PANEL 252BF HAS TWO 12 INCH CRACKS. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR FDEA201207282737Floor Panel · crackedFLOOR PANEL 252PH HAS ONE 12 INCHE CRACK. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR USAA2012073000012Floor Panel · delaminatedS1 CHECK - DELAMINATION ON FLOOR PANEL 151LF BETWEEN FR56 TO FR58 & BETWEEN Y254 TO -Y254. REPLACED FLOOR PANEL 151LF IAW A320 AMM 53-42-14.SDR USAA2012073100010Floor Panel · delaminated2S CHECK - DELAMINATION ON FLOOR PANEL NR 261PF BETWEEN FR68 TO FR69 & BETWEEN -Y765 TO Y765. REPLACED FLOOR PANEL NR 261PF IAW A320 SRM 53-02-00 FIG 209.SDR FDEA201207262708Floorboard · damagedFLOORDBOARD 251BH, IMPACT DAMAGE 6" AT SURF AROUND CLEVIS CUT OUT. FABRICATED REPLACEMENT FLOORDBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207262707Floorboard · damagedFLOORBOARD 252YG CRUSHED AT UPPER SURFACE AROUND CLEVIS ADAPTER CUTOUT. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207262706Floorboard · damagedFLOORBOARD 242ZJ, THREE AREAS AROUND THE CLEVIS OUTER PLY CRUSHED AND THREE BAD INSERTS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-00, REV J.SDR FDEA201207262705Floorboard · damagedFLOORBOARD 242EK, HAS IMPACT AT CLEVIS ADAPTOR CUT-OUT DEFECT MEASURES 10 INCHES LONG, UPPER SURFACE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207262704Floorboard · crackedFLOORBOARD IDENTIFIED AS 232RG IS CRACKED DOWN THE WIDTH CENTER. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207262703Floorboard · damagedFLOORBOARD 252VF CRUSHED AT THE EDGE AND AROUND THE CLEVIS ADAPTOR CUT OUT. FABRICATED REPLACEMENT FLOORBOARD DWG SRZ 25-005, REV J.SDR FDEA201207262702Floor Panel · crackedMAIN CARGO DECK FLOOR PANEL NR 251 JF IS CRACKED IN HALF AT A44 CLEVIS AREA, FABRICATED REPLACEMENT FLOOR PANEL IAW DWG SRZ 25-005, REV J.SDR DALA12004853124Floor Panel · damagedFORWARD UTILITY FLOOR PANEL 231AF CORRODED ON UPPER SURFACE. INSTALLED NEW FLOOR PANEL.SDR DALA12004513131Floor Panel · crackedAFT UTILITY FLOOR PANEL 261DF IS CRACKED, L=8 INCH. FLOOR PANEL REPLACED IAW DRAWING 3D25-40640.SDR DALA12004503131Floor Panel · delaminatedFORWARD CABIN FLOOR PANEL 222CF IS DELAMINATED L=7 INCH W=3 INCH. FLOOR PANEL REPLACED IAW DRAWING 3D25-40640.
Back to JASC 5321