JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA12004493131Floor Panel · delaminatedFORWARD CABIN FLOOR PANEL 231BF DELAMINATED L=5 INCH W=3 INCH. FLOOR PANEL REPLACED. IAW DRAWING 3D25-40640.SDR DALA12004483131Floor Panel · delaminatedFORWARD CABIN FLOOR PANEL 221EF DELAMINATED L=4 INCHES W=4 INCHES. FLOOR PANEL REPLACED. IAW DRAWING 3D25-40640.SDR DALA12004473131Floor Panel · corrodedFORWARD CABIN FLOOR PANEL 221DF IS CORRODED AND DELAMINATED. FLOOR PANEL REPLACED. IAW DRAWING 3D25-40640.SDR DALA12004163131Floor Panel · delaminatedFORWARD CABIN FLOOR PANEL 232DF IS DELAMINATED. FABRICATED NEW FLOOR PANEL PER DRAWING 3D25-40640 ORIG MAT 22 1/2 INCH BY 57 INCH DAMAGE DIMENSIONS L=3 FT W=2 FT.SDR DALA12004143131Floor Panel · corrodedFORWARD CABIN FLOOR PANEL 231CF HAS AN INSERT CORRODED AND DELAMINATED, L=3 INCH W=2 INCH. FLOOR PANEL REPLACED. REFERENCE DRAWING 3D25-40640.SDR DALA12004133131Floor Panel · delaminatedFORWARD CABIN FLOOR PANEL 231EF DELAMINATED, L=6 INCHES W=2 INCHES. FLOOR PANEL REPLACED. REFERENCE 3D25-40640.SDR IPXA2574587Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 232XDF IS DAMAGED. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574586Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 231XJF IS DAMAGED. FABRICATE FLOOR PANEL IAW EO B757-5230-9692-H.SDR IPXA2574585Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XNF DAMAGED AT BOTH EDGES. FABRICATED MAIN CARGO FLOOR PANEL IAW EO B757-5320-9692-H.SDR FDEA201207252677Floorboard · damagedFLOORBOARD 131QF HAS 45 INCHES OF EDGE DAMAGE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207252676Floorboard · damagedFLOORBOARD 131SG HAS 1 X 9 INCH PIECE TORN OFF & 6 INCHES OF DELAMINATED. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207252675Floorboard · damagedFWD CARGO BAY FLOORBOARD 131NG HAS PUNCTURED, CRACKED & EDGE DISBONDED. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207252674Floorboard · damagedFLOORBOARD 252UH OUTER PLY AFT OF CUTOUT CRUSHED APPROX 6 INCHES. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201207252673Floorboard · crackedFLOORBOARD 232YG HAS PUNCTURE AND CRACK ON FORWARD EDGE (5"), AND PUNCTURE AND CRACKED 8 INCHES AROUND CLEVIS ADAPTER CUTOUT. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-055, REV J.SDR FDEA201207252672Floorboard · damagedFLOORBOARD 232JG HAS AREA OF IMPACT DAMAGE, 9", ON INBD SIDE, AND EDGE FILLER MISSING ALONG ENTIRE AFT EDGE. FABRICATED FLOORBOARD IAW DWG SRZ 25-005 REV J.SDR FDEA201207252671Floorboard · crackedFLOORBOARD 232HG HAS IMPACT DAMAGED AND CRACK (5") AT AFT OTBD CORNER. FABRICATED FLOORBOARD IAW DWG SRZ25-005, REV J.SDR DALA12004673131Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151ZG DELAMINATED. FABRICATED NEW FLOOR PANEL IAW DWG NR 3D25-40532. DAMAGE DIM: L=3.0 W=1.1.SDR DALA12004613131Floor Panel · puncturedAFT CARGO FLOOR PANEL 161NF MULTIPLE AREAS PUNCTURED. FABRICATED NEW FLOOR PANEL IAW DWG NR 3D25-40532. DAMAGE DIM: L=0.25 W=0.2 D=0.30.SDR DALA12004603131Floor Panel · delaminatedAFT CARGO FLOOR PANEL 161PF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW DRWG NR 3D25-40532. DAMAGE DIM: L=1.0 W=1.0 D=0.4.SDR DALA12004463131Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151DE DELAMINATED. FLOOR PANEL WAS FABRICATED IAW DRAWING 3D25-40532. DAMAGE DIM: L=1.0 W=1.0.SDR DALA12004453131Floor Panel · puncturedAFT CARGO FLOOR PANEL 151GE PUNCTURED, FLOOR PANEL FABRICATED IAW DRAWING 3D25-40532. DAMAGE DIM: L=1.0 W=.75 D=0.30.SDR DALA12004443131Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151VG DELAMINATED. FABRICATED NEW FLOOR PANEL IAW DWG 3D25-40532. DAMAGE DIM: L=1.0 W=0.9 D=0.3.SDR DALA12004433131Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151UG DELAMINATED. FABRICATED NEW FLOOR PANEL 151UG IAW DWG 3D25-40532. DAMAGE DIM: L=2.0 W=1.0.SDR DALA12004423131Floor Panel · damagedAFT CARGO FLOOR PANEL 151PE DAMAGED "2 BY 4". FABRICATED NEW FLOOR PANEL 151PE IAW DWG 3D25-40532. DAMAGE DIM: L=4.0 W=2.0 D=0.2.SDR DALA12004413131Floor Panel · damagedAFT CARGO FLOOR PANEL 151CE DAMAGED "3 BY 5". FABRICATED NEW FLOOR PANEL DWG. 3D25-40532. DAMAGE DIM: L=3.0 W=5.0 D=0.2.SDR DALA12004403131Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151AE DELAMINATED. FABRICATED NEW FLOOR PANEL 151AE IAW DRWG 3D25-40532. DAMAGE DIM: L=3.0 W=1.0.SDR DALA12004393131Floor Panel · puncturedAFT CARGO FLOOR PANEL 151BE PUNCTURED. FABRICATED NEW FLOOR PANEL 151BE IAW DRWG 3D25-40532. DAMAGE DIM: L=3.0 W=2.5 D=0.25.SDR DALA12004383131Floor Panel · delaminatedFORWARD CARGO FLOOR PANEL 131CG DELAMINATED. FABRICATED NEW FLOOR PANEL 131CG IAW A319 DWG NR 3D25-40532. DAMAGE DIM: L=3.0 W=0.75.SDR ASOA2012080902046Floor Skin · crackedLT SIDE OF FWD AVIONIC BAY FLOOR SKIN CRACKED AT FS 193. REPAIRED IAW GREO 670-53-11-509.SDR DALA12003983131Floor Panel · corrodedFORWARD CABIN FLOOR PANEL 231AF IS CORRODED. FLOOR PANEL WAS REPLACED PER EO 5242-01006.SDR FDEA201207232648Deck Plate · damagedBS 1681 DECK PLATE AT RBL 36 HAS DOUBLE HOLE DRILLED. REPAIRED IAW SRM 53-60-51, ALTERNATIVE FIG 201, REPAIR 2, REV 106. REPAIR IS MAJOR.SDR FDEA201207232645Deck Plate · damagedCABIN DECK PLATE, BS 1681, RBL 60 TO LBL 60 HAS DAMAGE. REPAIRED IAW EA F-5310-163108, PART 1, AFT DECK PLATE BLEND OUT REPAIR AT BS 1681.8, RBL 52.5. REPAIR IS MINOR.SDR IPXA2574570Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 251XFF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR FDEA201207222641Floorboard · crackedMAIN DECK CARGO FLOORBOARD 251QH HAS AN 8 INCH CRACK AROUND CLEVIS CUT OUT. FABRICATED FLOORBOARD IAW DWG SRZ 25-005.SDR FDEA201207222640Floor Panel · crackedMAIN DECK CARGO AT FR 60 TO 62 INBETWEEN CARGO TRACKS 2L AND 3L FLOOR PANEL 250UH HAS A 7 INCH CRACK IN HONEYCOMB SKIN. FABRICATED NEW FLOOR PANEL IAW DWG SRZ 25-005 REV. JSDR USAA2012080600021Floor Panel · corroded2S CHECK - CORROSION ON FLOOR PANEL 222FF BETWEEN FR16 TO FR20, S23R & BETWEEN -Y1292 TO -Y765. REPLACED FLOOR PANEL 222FF IAW A319 AMM 53-12-12-400-001-A & JOB CARD 26C22053014.SDR USAA2012072600030Floor Panel · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR PANEL 221FF BETWEEN FR16 TO FR20 & BETWEEN Y1292 TO Y1732. REPLACED FLOOR PANEL 221FF IAW A320 SRM 51-72-11.SDR USAA2012072600029Floor Panel · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR PANEL 222FF BETWEEN FR16 TO FR20 & BETWEEN -Y1292 TO -Y1732. REPLACED FLOOR PANEL 222FF IAW A320 SRM 51-72-11.SDR IPXA12574517Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 252XDF HAS DELAMINATION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574707Floor Panel · damagedINSPECTION TYPE:C, MAIN CABIN FLOOR PANEL 252XTF DAMAGED AND REQUIRES STEP CUT. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2574633Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 251XGF HAS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574514Floor Panel · mismanufacturedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 252XFF MISMANUFACTURED. FABRICATED FLOOR PANEL IAW EO B757-5320- 9692-HSDR IPXA2574489Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 231XEF HAS DAMAGED INSERT. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574488Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 231XBF HAS DAMAGED INSERT. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574487Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 231XFF HAS DAMAGED INSERT. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574486Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 231XCF HAS DAMAGED INSERT. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574485Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 231XVF DELAMINATED EDGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574467Floorboard · delaminatedINSPECTION TYPE:C, MAIN CARGO COMPARTMENT FLOORBOARD 231XHF DELAMINATION EDGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR CALA2012071800462Pressure Deck · corrodedSLOPING PRESSURE DECK WEB BETWEEN BS 955-959 LBL 88-96 SLOPING PRESSURE DECK WEB DAMAGED. REPAIRED IAW ECRA 5310-05550, HFEC AND OPENING HOLES INSPECTION, NO CRACK, ATTACH FORM 44.0008 ITEM 1-28. ACCOMPLISHED DIP CONTROL NR 16603.SDR IPXA2174500Floorboard · puncturedINSPECTION TYPE: 1C, MAIN CABIN FLOORBOARD 241ZL HAS LOWER SKIN PUNCTURED. ACCOMPLISHED REPAIR ON FLOORBOARD NR IAW EO A300-5320-42721-B, PARA 6A.
Back to JASC 5321