JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2572310Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 232XMF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572303Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XBF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW B757-5320-9692-H.SDR IPXA2172293Floor Panel · delaminatedINSPECTION TYPE: 10YR, FLOOR PANEL 241YK IS DELAMINATED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B.SDR DALA1214403119Floor Panel · puncturedFWD CARGO COMPARTMENT SLOPE PANEL 132DG HAS MULTIPLE PUNCTURES. FABRICATED NEW SLOPE PANEL 132DG IAW DWG# 3D25-40532. DAMAGE DIA. L=2.0" X W=2.0".SDR DALA1214383119Floor Panel · puncturedFWD CARGO COMPARTMENT SLOPE PANEL 132EG HAS PUNCTURES. FABRICATED NEW SLOPE PANEL 132EG IAW DWG# 3D25-40532. DAMAGE DIA. L=4.5" X W=3.5".SDR DALA1214373119Floor Panel · puncturedFWD CARGO COMPARTMENT SLOPE PANEL 131DG HAS PUNCTURES. FABRICATED NEW SLOPE PANEL 131DG IAW DWG# 3D25-40532. DAMAGE DIA L=3.75" X W=4.0". RETAIN FOR RECORDS.SDR IPXA12572108Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 232XPF MISSING INSERTS AND DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572092Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 232 XCF MISSING INSERTS AND DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR FDEA201203070804Floorboard · damagedFLOORBOARD 252VF AREA IMPACT DAMAGE AND CRUSHED CORE. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ-25-005 REV JSDR FDEA201203070803Floorboard · delaminatedFLOORBOARD 252PH AREA DELIMINATION. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ-25-005, REV J.SDR FDEA201203070802Floorboard · crackedFLOORBOARD 242EK CRUSHED CORE AND CRACK FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ-25-005, REV J.SDR FDEA201203070801Floorboard · damagedAT ZONE 241BET, FR 30 AND FR 34 FLOORBOARD 241TH EDGE DAMAGES AND DEFORMED FABRICATED FLOORBOARD IAW DWG SRZ-25-005, REV J.SDR FDEA201203070800Floor Panel · damagedFLOOR PANEL 242RG CRUSHED CORE AND IMPACT DAMAGED FABRICATED FLOOR PANEL 242 RG IAW DWG SRZ 25-005, REV J.SDR UALA2012030801527Floor Panel · damagedFLOORBOARD IN FRONT OF LAV 131 IS SPONGY. REPLACED FLOOR PANEL REF SFOOV WRITE UP B3260X.SDR FDEA201203060789Floor Panel · brokenMAIN DECK FLOOR PANEL 241LK FOUND BROKEN. FLOOR PANEL R & R IAW AMM 53-10-25, REV 52.2. FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR IPXA2572382Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO COMPT FLOORBOARD 232XFF MULTIPLE DELAMINATIONS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572375Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 232XVF IS DAMAGED AT INSERT ON LWR OTBD EDGE OF PANEL. REPLACED FLOOR PANEL 232XVF IAW EO B757-5320-9692-H.SDR IPXA2572374Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOORBOARD 241XCF DELAMINATED FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572372Floorboard · damagedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOORBOARD 231XRF IS DAMAGED AT FWD END. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572371Floorboard · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO DECK FLOORBOARD 231XPF HAS MULTIPLE AREAS OF DELAMINATION AND PULLED INSERTS. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572370Floorboard · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOORBOARD 231XHF HAS MULTIPLE DELAMATED AND MOISTURE INGESTION. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572367Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOORBOARD 231XJF HAS MULTIPLE DELAM AND MOISTURE INGESTION AND BROKEN INSERT. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572366Floorboard · puncturedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOORBOARD 231XVF HAS PUNCTURE. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572363Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 231XLF HAS PUNCTURE AND AREA OF DELAM. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572362Floorboard · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO DECK FLOORBOARD 232XSF HAS PULLED AND DAMAGED INSERTS. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572339Floorboard · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO DECK FLOORBOARD 231XUF HAS DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572338Floorboard · delaminatedINSPECTION TYPE:C-CK MAIN CARGO DECK FLOORBOARD 232XPF HAS PULLED INSERTS AND DELAM ON FWD EDGE AND FWD OTBD CORNER. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572337Floorboard · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO DECK FLOORBOARD 231XAF DELAM ON EDGES OF PANEL. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572336Floorboard · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO DECK FLOORBOARD 232XDF HAS MULTIPLE DELAM AND MOISTURE INGESTION. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572335Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOORBOARD 241XJF HAS 1 DAMAGED INSERT. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572334Floor Panel · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOOR PANEL 231XWF HAS DELAMINATED. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2572332Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOORBOARD 232XXF DELAMINTED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572329Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOORBOARD 232XHF DELAMINTED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572328Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOORBOARD 231XNF DELAMINTED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572327Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOORBOARD 241XAF DELAMINTED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572326Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOORBOARD 232XAF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572323Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO DECK FLOORBOARD 231XFF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572311Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 232XNF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572307Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 232XJF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572306Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 232XEF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572305Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 232XCF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572304Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 232XWF DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572259Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XYF HAS DELAMINATION. FABRICATED A REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-HSDR IPXA2672227Floor Panel · dentedINSPECTION TYPE: 9C FLOOR PANEL FOUND WITH TWO PUNCTURES AND NINE DENTS AT BS 732 TO 825, LBL 55 TO 77. MCD FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR DALA1214413119Floor Panel · delaminatedAFT CARGO SLOPE PANEL 152WG DELAMINATED. AFT CARGO SLOPE PANEL 152WG FABRICATED NEW IAW DWG 3D25-40532. DAMAGE DIA. L= 1.75" X W=1.0". RETAIN FOR RECORDS.SDR DALA1213973119Floor Panel · delaminatedFLOOR PANEL 241KF DELAMINATED. FLOOR PANEL 241KF FABRICATED NEW ON STAM TRAVELER T12/920943 P/N DA-D5367161600000 IAW DWG 3D25-40640. DAMAGE DIM. L=2.75" X W=3.75.SDR DALA1213943119Floor Panel · delaminatedFWD CABIN FLOOR PANEL 231KF IS DELAMINATED, 18" X 3" AREA FWD CABIN FLOOR PANEL 231KF. FABRICATED NEW ON STAM TRAVELER T12/921249 P/N DA-5367160100000 IAW DWG 3D25-4D640.SDR DALA1213933119Floor Panel · delaminatedFLOOR PANEL 242KF DELAMINATED. FLOOR PANEL 242KF FABRICATED NEW ON STAM TRAVELER T12/920944 P/N DA-D5367161600100 IAW DWG# 3D25-40640. DAMAGE DIM. L=3.5" X W=3.5".SDR DALA1213883119Floor Panel · delaminatedAFT CARGO COMPARTMENT FLOOR PANEL 151ZG DELAMINATED. FABRICATED FLOOR PANEL 151ZG ON STAM TRAVELER T12/921125 IAW DWG# 3D25-40532. DAMAGE DIM. L=4.5" X W=3.75".SDR DALA1213873119Floor Panel · damagedFWD CARGO COMPARTMENT FLOOR PANEL 131CG HAS MULTIPLE PUNCTURES AND DELAMINATED. FABRICATED FLOOR PANEL. DAMAGE DIM. L=5.6" X W=5.6".
Back to JASC 5321