JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201203060794Floorboard · damagedFLOORBOARD 252UH AREA IMPACT DAMAGE AND CRUSHED CORE FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201203060793Floorboard · damagedFLOORBOARD 251DG CRUSHED AT CLEVIS ADAPTER CUT OUT FR 67 FARICATED. REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201203060792Floorboard · crackedFWD CARGO BAY FLOORBOARD 131NG HAS MULTIPLE PUNTURES THRU LOWER SKIN (20 EA TOTAL WITH 2EA CRACKS IN UPPER SKIN TOTAL CRACKS 15 IN) FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR FDEA201203060791Floorboard · damagedAFT CARGO BAY FLOORBOARD 151SF HAS 3 SQ IN OF IMPACT DAMAGE FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.SDR USAA2012030700001Floor Panel · delaminatedC11 CHECK - DELAMINATION ON FLOOR PANEL # 221DF BETWEEN FR16 TO FR20, Z-500, Y=0. REPLACED FLOOR PANEL # 221DF IAW IRM 9701 REV G.SDR IPXA2172470Floorboard · puncturedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 231WG IS PUNCTURED IN SEVERAL PLACES. FABRICATED MAIN CABIN FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA2172435Floorboard · delaminatedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 261BM IS CRACKED AND DELAMINATED AT FWD OTBD CORNER. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD IAW EO A300-5320-42721-B, PARA 6A AND EO A300-5320-42722-B, PARA 6A.SDR IPXA2172426Floor Panel · puncturedINSPECTION TYPE: 10YR, FLOOR PANEL 231LJ IS PUNCTURED & TORN. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B.SDR IPXA2172424Floor Panel · crackedINSPECTION TYPE: 10YR, FLOOR PANEL 251YM IS CRACKED & DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B.SDR IPXA2172417Floor Panel · crackedINSPECTION TYPE: 10YR, MDCC FLOOR PANEL 262HM CRACKED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B.SDR IPXA2172416Floor Panel · damagedINSPECTION TYPE: 10YR, FLOOR PANEL 231MJ HAS RUSTED INSERTS AND IS CHAFED. REPAIRED FLOOR PANEL 231MJ IAW EO A300-5320-42721-B AND DWG B532270725.SDR IPXA2172292Floor Panel · crackedINSPECTION TYPE: 10YR, FLOOR PANEL 251LJ IS CRACKED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B.SDR IPXA2172290Floor Panel · tornINSPECTION TYPE: 10 YR, FLOOR PANEL 231RT TORN AT CORNER. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B.SDR IPXA2172289Floor Panel · crackedINSPECTION TYPE :10YR, MDCC FLOOR PANEL 232EF IS CRACKED AND PUNCTURED. REPAIRED FLOOR PANEL IAW EO NR A300-5320-42721-B.SDR IPXA2172242Floor Panel · crackedINSPECTION TYPE: 10YR, FLOOR PANEL 231RG IS CHAFED ON UPPER SKIN AND CRACKED ON LOWER SKIN. REPAIRED FLOOR PANEL IAW EO A300-5320-42722-B.SDR IPXA2172224Floor Panel · delaminatedINSPECTION TYPE: 10YR, FLOOR PANEL 231KJ IS DELAMINATED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B.SDR IPXA2172223Floor Panel · puncturedINSPECTION TYPE: 10YR, MDCC FLOOR PANEL 231KH IS PUNCTURED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B.SDR IPXA2172222Floor Panel · puncturedINSPECTION TYPE: 10YR, MDCC FLOOR PANEL 231KG IS PUNCTURED. REPAIRED MDCC FLOOR PANEL IAW EO A300-5320-42721-B.SDR ASOA201200775Floor Panel · corrodedCABIN AREA PRESSURE FLOOR CORRODED AT FS 529.00 AND BETWEEN LBL 36 TO STR 18 2EA PLACES. BLENDED CORROSION IAW SRM 51-21-06. PERFROMED UT THICKNESS INSPECTION OF BLENDED AREAS IAW MAC NDT PROCEDURE UT-3. MINIMUM MATERIAL REMAINING .072", ORIGINAL IS .080"SDR ASOA201200773Floor Panel · corrodedCABIN AREA PRESSURE FLOOR CORRODED AT FS 529 BETWEEN RBL 36 AND STR 18 2 EA PLACES. PERFORM EC/TC 601R-53-41-666. COMPLIED WITH EC/TC REO 601R-53-41-666 AND REO 601R-53-41-666, REV B.SDR ASOA201200771Floor Panel · corrodedCABIN AREA PRESSURE FLOOR CORRODED AT FS 513 AND BETWEEN RBL 36 AND STR 18. COMPLIED WITH EC/TC REO 601R-53-41-666 AND REO 601R-53-41-666, REV B.SDR ASOA201200769Pressure Panel · corrodedCABIN AREA PRESSURE FLOOR CORRODED AT FS 559.00 BETWEEN RBL 36 AND STR 18. COMPLIED WITH EC/TC REO 601R-53-41-666 AND REO 601R-53-41-666. RII FOUND TO BE SATISFACTORY. (SDR CLOSED)SDR C77A201203080013Floor Panel · corrodedFLOOR PANEL DOUBLER IS CORRODED FR13-16. R & R FLOOR PANEL DOUBLER IAW SRM 51-41-01 & 51-43-01 IAW EO E175-5300-049 ON WO 461536-138.SDR C77A201203080012Sill · corrodedLEFT SILL PANEL, IS CORRODED FR 13-16. R & R LT SILL PANEL IAW SRM 51-41-01 & 51-43-01 EO E175-5300-049 ON WO 461536-136.SDR C77A201203080006Floor Panel · corrodedLEFT FLOOR PANEL LEADING EDGE IS CORRODED AROUND FASTENERS AT FRAME 87. R & R FLOOR PANEL IAW SRM 51-41-01 & 51-43-01 IAW EO E175-5300-048 ON WO 461536-112.SDR C77A201203080002Floor Panel · corrodedLEFT FLOOR PANEL IS CORRODED AT FRAME 85. R & R IAW SRM 51-41-01 & 51-43-01 IAW EO E175-5300-048 ON WO 461536-107.SDR IPXA12672035Floor Panel · delaminatedMAIN CARGO DECK FLOOR PANEL DAMAGED POS 3R CENTER. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR UALA2012030501379Floor Panel · damagedFLOOR SOFT IN AISLE BETWEEN ROW 35 & 36 BY FLIGHT ATTENDANT. AREA MEASURES 18' X 18' BETWEEN FRAME 61 AND 62. REPLACED CABIN FLOOR PANEL.SDR IPXA2672028Floor Panel · puncturedMAIN CARGO DOOR FLOOR PANEL 4R HAS A PUNCTURE, DELAM, PN 143T5876-85. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA2172469Floorboard · damagedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD 241BQ IS DAMAGED AT CORNER. FABRICATED MAIN CABIN FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA2172468Floorboard · delaminatedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD 242YK IS DELAMINATED AT LOWER SKIN. FABRICATED MAIN CABIN FLOORBOARD IAW EO A300-5320-40552-B, APPENDIX B.SDR IPXA2172467Floorboard · crackedINSPECTION TYPE: 10YR, MAIN CABIN FLOORBOARD NR 242VM IS CRACKED AT LOWER SECTION. FABRICATED MAIN CABIN FLOORBOARD IAW EO A300-5320-40552-B APPENDIX B.SDR IPXA2172425Floor Panel · delaminatedINSPECTION TYPE: 10YR, FLOOR PANEL 241LJ DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B.SDR IPXA2172422Floor Panel · brokenINSPECTION TYPE: 10YR, FLOOR PANEL 241NK BROKEN AT CORNER. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B.SDR IPXA2172421Floor Panel · damagedINSPECTION TYPE: 10YR, FLOOR PANEL 241SN DAMAGED AT CORNER. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B.SDR IPXA2172418Floor Panel · delaminatedINSPECTION TYPE: 10YR, FLOOR PANEL 232WG DELAMINATED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B.SDR IPXA2172225Floor Panel · damagedINSPECTION TYPE: 10YR, FLOOR PANEL 242BF DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B.SDR IPXA2172194Floor Panel · brokenINSPECTION TYPE: 10YR, FLOOR PANEL 241RT INSERT BROKEN OUT. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-40552-B.SDR IPXA2172191Floor Panel · damagedINSPECTION TYPE: 10YR, FLOOR PANEL 241EF DAMAGED. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B.SDR IPXA2172190Floor Panel · damagedINSPECTION TYPE: 10YR, FLOOR PANEL 241MN DAMAGED AT EDGE. REPAIRED FLOOR PANEL IAW EO A300-5320-42721-B.SDR FDEA201203040773Floorboard · delaminatedAFT FUSELAGE TAIL SECTION FLOORBOARD 312AF HAS 7 INCH X 7 INCH AREA OF DELAM ON FWD SIDE OF PULLEYS COVER. FABRICATED FLOORBOARD IAW DWG SRZ-25-005, REV J.SDR IPXA2672017Floor Panel · damagedMAIN CARGO FLOOR PANEL HAS A 3" BY 1" HOLE AT POS 6/7 PANEL CENTER, IDENTIFIED PANEL FROM POS 6/7 CENTER AS PN 145T5876-60 IAW EO B767-5320-9693H. FABRICATED A REPLACEMENT PANEL FROM A402H ACCOMPLISHED PARA B, STEP 5 & 6 REF EO B767-5320--9693-H.SDR IPXA2672016Floor Panel · damagedMAIN CARGO COMPARTMENT FLOOR PANEL HAS A 3" BY 1" HOLE AT POSITION 4/5 CENTER PANEL 31" AFT OF POS 4. IDENTIFIED PANEL FROM POSITION 4/5 CENTER AS PN 143T5876-112 IAW EO B767-5320-9693 H. FABRICATED A REPLACEMENT PANEL FROM A402H ACCOMPLISHED PARA B, STEP 5 &SDR IPXA2672015Floor Panel · damagedMAIN CARGO COMPARTMENT FLOOR PANEL HAS A .5" DIAMETER HOLE AT POSITION 4/5 CENTER PANEL, 59" FWD FROM POS 4. IDENTIFIED PANEL FROM POS 4/5 CENTER AS PN 143T5876-112 IAW EO B767-5320-9693H, FABRICATED A REPL PANEL FROM A402H ACCOMPLISHED PARA B STEP 5&6 REF EOSDR IPXA2572025Floorboard · damagedINSPECTION TYPE:C-CK, FOUND DAMAGE TO TOP SIDE OF FLOORBOARD 231XLF. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2172472Floorboard · corrodedINSPECTION TYPE: 10YR, MAIN ENTRY DOOR AREA FLOORBOARD 221FF IS CORRODED AT LOWER SURFACE. ACCOMPLISHED REPAIR ON MAIN ENTRY DOOR FLOORBOARD IAW EO A300-5320-46437-A, PARA 6A.SDR FDEA201203030762Floor Panel · delaminatedMAIN DECK FLOOR PANEL 241GJ FOUND DELAMINATED. FLOOR PANEL R & R IAW AMM 53-10-25, REV 52.2. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005 REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201203030755Floor Panel · delaminatedMAIN DECK FLOOR PANEL 242ZJ FOUND DELAMINATED. FLOOR PANEL R & R IAW AMM 53-10-25, REV 52.2. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201203030754Floor Panel · delaminatedMAIN DECK FLOOR PANEL 232YG FOUND DELAMINATED. FLOOR PANEL REMOVED AND REPLACED IAW AMM 53-10-23, REV 52.2. NEW FLOOR PANEL 232YG FABRICATED IAW DWG SRZ-25-005 REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201203030752Floor Panel · delaminatedMAIN DECK FLOOR PANEL 241WH FOUND DELAMINATED. FLOOR PANEL R & R IAW AMM 53-10-25, REV 52.2. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005, REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.
Back to JASC 5321