JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2024121011574Floor Panel · corrodedFWD CABIN FLOOR FWD PASSENGER ENTRY DOOR FR19 FWD INBD CORNER CORRODED.-M-PIC SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0560:5321-2022/001 00448 CMOR: REMOVED AND REPLACED FWD PASSENGER DOOR ENTRANCE FLOOR PANEL, REF A220 AMP 53-00-47-11. (LP# 0697197)SDR DALA2024120911559Floor Panel · deterioratedSHIP 3145 DETERIORATED FLOOR PANEL 261PF IN AFT GALLEY AREA. CORRECTIVE ACTION: COMPLIED WITH ER/A 622222-14. (0698679)SDR AALA202412099059Floor Panel · smokeAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETUNRED TO DFW DUE TO SMOKE IN FORWARD GALLEY AFTER TAKEOFF FROM THE FLOOR UNDER COMPARTMENT 110 NEAR 1R DOOR. FLIGHT ATTENDANT SAYS THERE WAS SMOKE AND A VISIBLE SPARK UNTIL GALLEY POWER WAS SDR ASAA2024120554387Floor Panel · delaminatedMAIN CABIN - FLOOR PANEL 241AF IS DELAMINATED. GROUNDED - YES. REPAIRED DELAMINATION AND REMOVED AND REPLACED 43EA INSERTS ON FLOOR PANEL 241AF IAW B737-800 SRM 53-00-50-2R-1.SDR DALA2024120611485Fastener · elongated(LOG 0695033) ELONGATED FASTENER HOLE ON FLOOR MOUNTING STRUCTURE AT STA 1018.5, LBL 27, WL 208. ACCOMPLISHED REPAIR TO FLOOR SUPPORT STA 1018.5 LBL 27 WL 208 IAW ERA 622636-14.SDR DALA2024120511464Door · corroded(LOG 0694120) SUSPECTED CORROSION ON AND ADJCENT TO THE 311AL DOOR DUE TO SUSPECTED HUMAN WASTE FROM LAV TANK VENT. ALL REPAIRS ACCOMPLISHED PER ER/A 622268-14.SDR 2A6R202412050001Floor Skin · dentedDURING 1000 HOUR INSPECTION, DENT / DEBOND DAMAGE WAS DISCOVERED ON THE REAR CABIN FLOOR UPPER SKIN PANEL (PN: L533M1016237). A DETAILED DESCRIPTION OF THE DAMAGE AND AN APPROVED REPAIR PROCEDURE IS PROVIDED IN AIRBUS REPAIR DESIGN APPROVAL SHEET RDAS-EC135-5SDR SWAA2024121773973Floor Panel · delaminatedDELAMINATION ON CABIN FLOOR PANEL 241RF IN 2EA AREAS. (MARKED)<[01] REMOVED; REPAIRED AND REINSTALLED FLOOR PANEL 241RF PER AMM 53-21-00; 53-00-50-1A-1 AND 53-00-50-2R-0.;[02] TASK COMPLETESDR SWAA2024121773974Floor Panel · delaminatedDELAMINATION ON CABIN FLOOR PANEL 241SF. (MARKED)<[01] REMOVED; REPAIRED AND REINSTALLED FLOOR PANEL 241SF PER AMM 53-21-00; 53-00-50-1A-1 AND 53-00-50-2R-0.;[02] TASK COMPLETESDR DALA2024120511463Plate · corroded(LOG 0693506) CORROSION OUT OF LIMITS (DIMENSIONS: ORIGINAL THICKNESS: 0.040IN AND MINIMUM REMAINING THICKNESS: 0.028 IN) ON RH SIDEPLATE (UPPER AND LOWER FACES) STA 727 TO STA 727F, AND STA 767 TO 787 AT AFT CARGO COMPARTMENT. RH SIDEPLATE STA 727 TO STA 727FSDR DALA2024120511462Bracket · corroded(LOG 0692387) ACCESS DOOR 311AL HINGE BRACKET PN 65-54861-1 AND 65-54863-1 SHOW SIGNS OF CORROSION. REMOVED AND REPLACED HINGE BRACKETS PER ER/A 622268-14.SDR DALA2024120511461Access Door · corroded(LOG 0692371) ACCESS DOOR 311AL ADAPTER ASSY PN 148A6121-7 SHOWS SIGNS OF CORROSION. REMOVED AND REPLACED DOOR ADAPTER PER ER/A 622268-14.SDR DALA2024120511460Bracket · corroded(LOG 0692361) ACCESS DOOR 311AL HINGE BRACKET PN 148A6140-6 SHOWS SIGNS OF CORROSION. REMOVED AND REPLACED HINGE BRACKET PER ER/A 622268-14.SDR DALA2024120511466Plate · corroded(LOG 0693277) CORROSION ON LH SIDEPLATE (UPPER AND LOWER FACES) STA 727 TO STA 727F, STA 727F TO 847 AT AFT CARGO COMPARTMENT. LH SIDEPLATE FROM STA 727 TO STA 847 AT AFT CARGO COMPARTMENT WERE REPLACED PER B737-800 SRM 51-40-02-0G.SDR SWAA2024122073800Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241 GF DELAMINATED<[01] REMOVED AND REPLACED WITH NEW SERVICEABLE FLOOR PANEL IAW AMM 53-21-00.;[02] C/W INSPECTIONSDR SWAA2024122073801Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241 KF DELAMINATED<[01] REMOVED AND REPLACED WITH NEW SERVICEABLE FLOOR PANEL 241KF PER AMM 53-21-00.;[02] COMPLIED WITH CORRECTIVE ACTION #1.SDR SWAA2024122073802Floor Panel · delaminatedCENTER CABIN FLOOR PANEL 241 RF DELAMINATED<[01] REMOVED AND REPLACED FLOOR PANEL PER AMM 53-21-00-400-801.;[02] COMPLIED WITH CORRECTIVE ACTION#1.SDR DALA2024120511481Angle · corrodedSHIP 6704 MAIN CABIN, L-2 DOOR, STA 720 TO STA 720, FLOOR SUPPORT ANGLE HAS CORROSION. CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR SUPPORT AND ANGLE AT MAIN CABIN, L-2 DOOR, STA 720 TO STA 720, IAW B757-200 SRM 51-40-02, SRM. (0691636)SDR DALA2024120511477Beam · corrodedSHIP 6704 MAIN CABIN, FLOOR BEAM HAS CORROSION AT STA 365 RBL46 TO RBL59. CORRECTIVE ACTION: SUMMARY OF- EVALUATED BLENDED AREA WITH AT MAIN CABIN COMPARTMENT FLOOR BEAM STA 365.25 BWTN RBL. FOUND TO BE OUT LIMITS IAW B757 SRM 53-00-51. REPAIRED MAIN CABIN FLOSDR DALA2024120511458Beam · corroded(0691667) CORROSION ON FLOOR MOUNTING BEAM NEXT TO LAV MOUNTING BRACKET EDGE LOCATED AT STA 915.5, LBL 26, WL 208. WORK ACCOMPLISHED ON ER/A 622499-14 REV-ORIGINAL.SDR FDEA202412031771Floor Panel · damagedMAIN DECK CARGO COMPT FLOORBOARD PANELS 251MSF INSERTS TORN. FABRICATED ZONE 250 FLOORBOARD PANEL 251MSF ON VTMAE TRAVELER #T24/1787474 IAW DWG 11864182 REVISION D MAJOR REPAIRSDR FDEA202412031769Floor Panel · damagedMAIN DECK CARGO COMPT FLOORBOARD PANEL 241MDF DAMAGED. FABRICATED ZONE 240 FLOORBOARD PANEL 241MDF ON VTMAE TRAVELER #T24/1787472 IAW DWG 11863182 REVISION C MAJOR REPAIRSDR FDEA202412031768Floor Panel · damagedMAIN DECK CARGO COMPT FLOORBOARD PANEL 251MTF HAS SEVERAL INSERTS DAMAGED. FABRICATED ZONE 250 FLOORBOARD PANEL 251MTF ON VTMAE TRAVELER #T24/1787475 IAW DWG 1186182 REVISION D MAJOR REPAIRSDR DALA2024120311410Doubler · corroded(LOG 0689882) FWD CARGO COMPARTMENT INSTALLED DOUBLER BETWEEN STA 500C-500D BETWEEN S-27R TO S-27L HAS EVIDENCE OF CORROSION. REMOVED AND REPLACED FWD CARGO COMPARTMENT DOUBLER BETWEEN STA 500C-500D AND BETWEEN S-27R TO S-27L. IAW B737-900 SRM 51-40-02-0G, DWGSDR DALA2024120311383Web · crackedSHIP 3145 CRACK FLOOR STRUCTURE WEB LOCATED FROM FR68 TO FR69 AND STR 23LH AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR STRUCTURE WEB AS PER A319 SRM 51-42-11-801 AND SRM 51-72-11-911-001. (0689876)SDR AALA202412237923Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: DELAMINATED FLOOR PANEL 232UF IN PASSENGER CABIN. REPLACED FLOOR PANEL PER SRM 53-02-00.SDR AALA202412236688Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: DELAMINATED FLOOR PANEL 231CF AT PASSENGER CABIN FORWARD GALLEY AREA. REPLACED FLOOR PANEL PER SRM 53-02-00.SDR ASAA2024120154145Floor Panel · peelingCABIN FWD WET AREA FLOOR PANEL 141A5800-142 HAS PEELING FIBERS. (PARTS RACK). GROUNDED - YES. ACCOMPLISHED PERMANENT REPAIR ON CABIN FLOOR PANEL 141A5810-142 FACE SHEET IAW B737 SRM 53-00-50-2R-0.SDR DALA2024120211318Panel · delaminatedSHIP 3134 DELAMINATED FLOOR PANEL 261DF IN PASSENGER CABIN. CORRECTIVE ACTION: PERFORMED REPAIR INSTRUCTIONS ON FLOOR PANEL 261DF IN PASSENGER CABIN AS PER ER/A 621923-14. (687448)SDR DALA2024120211317Panel · delaminatedSHIP 3134 DELAMINATED FLOOR PANEL 261PF IN PASSENGER CABIN. CORRECTIVE ACTION: PERFORMED REPAIR INSTRUCTIONS ON FLOOR PANEL 261PF IN PASSENGER CABIN AS PER ER/A 621973-14. (0687443)SDR AALA202412308033Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: DELAMINATED PASSENGER CABIN FLOOR PANEL FROM SEAT 25A TO SEAT 27A. REPLACED FLOOR PANEL PER AMM B787 A-53-01-01-02A-520A-A / 720A-A.SDR AALA202412300759Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: DELAMINATED PASSENGER CABIN FLOOR PANEL FROM SEAT 4L TO SEAT 5L. REPAIRED FLOOR PANEL PER SRM B787-A-53-00-50-03A-663A-A.SDR AALA202412309723Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: DELAMINATED PASSENGER CABIN FLOOR PANEL AT SEAT 20H. REPLACED FLOOR PANEL PER AMM B787-A-563-01-01-02-520A-A/720A-A.SDR SWAA2024122372990Floor Panel · crackedPANEL 661BB HAS SEVERAL FASTENER HOLES DAMAGED ; PULLED SURFACE & CRACKING.<[01] FILLED DAMAGED HOLES; APPLIED PRE-PREG REPAIR PLIES AND COOKED REPAIR PER SRM 51-70-05-2R-9.;[02] ENTERED IN ERROR;[03] REPAIRED DAMAGED FASTENER HOLES PER SRM 51-70-05-2R-9.;[04]SDR AALA202412154914Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: PASSENGER CAMIN FLOOR PANEL AT MID GALLEY IS DELAMINATED. ACCOMPLISHED PERMANENT REPAIR TO DELAMINATION PER SRM B787-A-53-00-50-03A-663A-A.SDR AALA202412158627Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: PASSENGER CABIN FLOOR PANEL AT SEAT 30D IS DELAMINATEDD. ACCOMPLISHED PERMANENT REPAIR PER SRM B787-A-53-00-50-03A-663A-A.SDR DALA2024120311402Panel · corroded(LOG 0684962) CORROSION ON FLOOR PANELS OF CARGO COMPARTMENTS NBR: 140DF, 140CF, 140AF, 120DF, 120CF, 140BF, 120BF AND 120AF. FLOOR PANELS 140AF, FLOOR PANEL 140CF, FLOOR PANEL 120DF AND 140BF, FLOOR PANELS 120AF, 120BF AND 120CF, FLOOR PANEL 140DF WERE FABRICSDR DALA2024120211315Web · brokenSHIP 3134 BROKEN WEB BTW FR 30 TO FR 34 STR 38L IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED WEB AND FASTENERS LOC. BTW FR 30 TO FR 34 STR 38L IN FWD CARGO COMPARTMENT AS PER A319 SRM 51-42-11 AND SRM 51-7-11. (0686294)SDR DALA2024120211314Stringer · corrodedSHIP 3136 CORROSION STRINGER 44 FR 61 TO FR 62 IN AFT CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED SECTION STRINGER 44, LOC BTW FR 59 TO FR 64, IN AFT CARGO COMPARTMENT AS PER A319 51-42-11, A319 SRM 51-72-11. (0686284)SDR DALA2024120311401Beam · corroded(LOG 0684727) CORROSION ON FLOOR SUPPORT STA328 BTW RBL25 TO RBL56 AT CPAX. FLOOR SUPPORT BEAM STA 328 BTW RBL 1.10 TO RBL56 AT CPAX WAS REPAIRED PER B737-800 SRM 53-10-51-2R-7 PROCEDURE 7 REPAIR 7.SDR DALA2024120311400Stringer · corroded(LOG 0684353) CORROSION ON S-24 BTWN STA 887 S25R-S23 APROX ZONE 142 AT AFT CARGO COMPARTMENT. (C-2). SPLICE ON STRINGER 24 RH STA 887 WAS REPLACED PER B737-800 SRM 51-40-02-0G.SDR DALA2024113011277Beam · corrodedSHIP 3147 CORROSION FLOOR BEAM +Y765 LOCATED BTW FR 64 TO FR 66 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED SEAT TRACK AND FASTENERS PER A319 SRM 51-42-11 AND SRM 51-72-11. (0684491)SDR DALA2024120211371Cusp Web · crackedCRACKS ON LH CUSP WEB (3 EA) STA Y=657 & X=56 AND STA Y=716 & X=44.5 AND Y=888 & X=56 AT PASSENGER CABIN. SUMMARY OF NRC 00426: FABRICATED WEB STA Y-655 TO Y-715 PER B717-200 SRM 53-20-51-01 PROCEDURE 2. REPAIRED CUSP WEB STA 888 & X 56 PER B717-200 SRM 53-00-SDR DALA2024120211350Plate · corrodedSHIP 5652 CORROSION ON SIDE PLATE UPPER AND LOWER SURFACE ALSO CORROSION ON NUTS BTW STA Y=1410 TO STA Y=1530 S26L-S27L AT AFT CARGO COMPARMENT C2. CORRECTIVE ACTION: SUMMARY OF NRC 00376, SIDE PLATE BTW STA Y= 1410 TO STA Y=1530 S26L-S27L AT AFT CARGO COMPARMSDR DALA2024113011275Beam · corrodedSHIP 3145 CORROSION FLOOR BEAM -Y765 AND AT LEVEL FR68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A319 SRM 51-42-11-801, AND SRM 51-72-11. (0683454)SDR DALA2024113011274Beam · corrodedSHIP 3145 CORROSION FLOOR BEAM -Y765 AND AT LEVEL FR68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A319 SRM 51-42-11-801, AND SRM 51-72-11. (0683388)SDR DALA2024113011273Beam · corrodedSHIP 3147 CORROSION FLOOR BEAM -Y1162.5 LOCATED FROM FR68 TO FR69 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A319 SRM 51-42-11 AND A319 SRM 51-72-11. (0683310)SDR SWAA2024122772269Floor Panel · corrodedDOT 7L-015: AFT CARGO FLOOR PANEL 140EF IS CORRODED AT FASTENER HOLES<[01] EVALUATED AREA ON FLOOR PANEL 140EF; DAMAGE REMOVED HAS A MORE THAN 3 INCHES IN LENGHT; MORE OF THE LIMITS PERMITTED; THEREFORE IS OUT OF LIMITS I.A.W. SRM 53-00-53-1A-1. FABRICATED NEWSDR SWAA2024122772266Floor Panel · corrodedDOT 7L-016: AFT CARGO FLOOR PANEL 140BF IS CORRODED AT FASTENER HOLES<[01] EVALUATED ALLOWABLE LIMITS: DAMAGE IS MORE THE MAXIMUN LENGTH PERMITTED (MAXIMUN 3.0 IN) FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-1 ITEM 5 B A AND FABRICATED NEW FLOOR PANEL 140 BF IAW ASDR SWAA2024122772270Floor Panel · corrodedDOT 7L-017: AFT CARGO FLOOR PANEL 140CF IS CORRODED AT FASTENER HOLES<[01] UPON FURTHER INVESTIGATION FOUND THERE TO BE A TOTAL OF 38 INCHES OF CORROSION WITH A MAX ALLOWED LENGTH OF CORROSION BEING 3 INCHES FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 RECE
Back to JASC 5321