JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201201160185Floor Panel · delaminatedAFT CARGO COMPARTMENT FLOOR PANEL NR 152JF, FOUND DELAMINATED. R & R IAW AMM 53-10-33-04, REV 52.1. NEW FLOOR PANEL FABRICATED IAW DWG SRZ-25-005 REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. REV 113.SDR IPXA12671094Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL STA 754, RBL 4.7" HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA12571096Floor Panel · damagedINSPECTION TYPE:C-CHECK, FLOOR PANEL 252XUF HAS MULTIPLE LOOSE AND MISSING INSERTS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692.SDR ZZDA2012088Floor Panel · corrodedFWD CARGO COMPARTMENT FLOOR PANEL, CORROSION. ACCOMPLISHED FLOOR PANEL REPLACEMENT PER B717 SRM 53-20-01, 51-10-01.SDR IPXA2171146Floorboard · crackedINSPECTION TYPE:10YR, FWD CARGO FLOORBOARD NR 131AH IS CRACKED AT CTR. FABRICATED FWD CARGO FLOORBOARD NR 131AH IAW EO A300-5320-16407-E.SDR FDEA201201130158Floorboard · damagedFLOORBOARD 241HK CENTER SECTION IS CRUSHED WERE CLEVIS A TTACHES, FABRICATED REPLACEMENT FLOORBOARD 241 HK IAW DWG SRZ 25-005, REV J.SDR IPXA2571186Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 231XJF HAS PUNCTURE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2571171Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL AFT SECTION OF PANEL 251XEF DAMAGED. FABRICATED MAIN CARGO FLOOR PANEL 251XEF IAW EO B757-5320-9692-H.SDR IPXA2571169Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL AFT SECTION OF PANEL 232XSF HAS DAMAGE ON TOP SURFACE. FABRICATED NEW MAIN CARGO FLOORBOARD PANEL 232XSF IAW EO B757-5320-9 692-H.SDR IPXA12571079Floorboard · puncturedINSPECTION TYPE:C-CHECK, MAIN CARGO FLOOR 231 XGF HAS A PUNCTURE ON UPPER SURFACE. FABRICATED NEW MAIN CARGO FLOORBOARD 231 XGF IAW EO B757-5320 -9692-H.SDR FDEA201201130167Floorboard · damagedMAIN DECK 240, FLOORBOARD 242RJ CLEVIS ATTACHMENT SECTION IS BROKEN OFF. FABRICATED REPLACEMENT FLOORBOARD 242 RJ IAW SRZ 25-005, REV J.SDR FDEA201201130166Floorboard · crackedMAIN DECK FLOORBOARD 242LK HAS A 9" CRACK, FASTENER HOLE MISSING 1" SECTION OF CORE, AND END SECTION OF FLOORBOARD. FABRICATED REPLACEMENT FLOORBOARD 242 LK IAW DWG SRZ 25-005, REV J.SDR FDEA201201130165Floorboard · crackedFLOORBOARD 252GF, CRACKED AT UPPER SURFACE 3 EA. FABRICATED REPLACEMENT PANEL 252 GF IAW DWG SRZ 25-005, REV J.SDR FDEA201201130157Floorboard · crackedFLOORBOARD 241PF CRACKED 1.5 INCHES AT CLS ADAPTER CUT-OUT. FABRICATED REPLACEMENT FLOORBOARD 241 PF IAW DWG SRZ 25-005 REV JSDR FDEA201201130155Floorboard · crackedFLOORBOARD 252BF, CRACKED AT UPPER SURFACE 4 EA FABRICATED REPLACEMENT FLOORBOARD 252 BF IAW DWG SRZ 25-005. REV J.SDR FDEA201201130154Floorboard · crackedFLOORBOARD 242 ZJ HAS 5 AREAS WERE CLEVIS ATTACHES THAT ARE CRUSHED AND ALSO A 9 '. CRACK FABRICATED REPLACEMENT FLOORBOARD 242 ZJ IAW DWG SRZ 25-005, REV J.SDR FDEA201201130153Floorboard · crackedFLOORBOARD 241 DF CRACKED AT 3 PLACES LOWER SURFACE. FABRICATED FLOORBOARD 241 DF IAW DWG SRZ 25-005, REV J.SDR FDEA201201130152Floorboard · damagedMAIN DECK FLOORBOARD 241 TH PANEL IS CRUSHED WHERE CLEVIS IS ATTACHED FABRICATED. FLOORBOARD 241TH IAW DWG SRZ 25-005, REV J.SDR FDEA201201130151Floorboard · delaminatedFLOORBOARD 251 VF DISBONDED/ DELAMINATED AT UPPER SURFACE FABRICATED. REPLACEMENT PANEL 251VF IAW DWG SRZ 25-005, REV J.SDR IPXA2571185Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 251XQF HAS PUNCTURE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2571172Floorboard · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD 252XSF FWD INBD EDGE DAMAGED. FABRICATED NEW MAIN CARGO FLOORBOARD 252XSF IAW EO B757-5320-9 692-H.SDR IPXA2571126Floor Panel · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOOR PANEL 252XUF IS DELAMIANATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12571071Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 242XFF INSERT MISSING FABRICATED MAIN CARGO COMPARTMENT FLOOR PANEL 242XFF IAW EO B757-5320-9692-H.SDR IPXA12571065Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD PANEL 232XSF DELAMINATED. FABRICATED MAIN CARGO FLOORBOARD PANEL 232XSF IAW EO B757-5320-9692-H.SDR IPXA12571064Floorboard · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO FLOORBOARD PANEL 251XAF DELAMINATED. FABRICATED MAIN CARGO FLOORBOARD PANEL 251XAF IAW EO B757-5320-9692-H.SDR IPXA12571062Floor Panel · dentedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 252XLF UPPER SURFACE IS DENTED IN 2" BY 2" WITH COMPOSITE CRACKED ALONG EDGE OF DENT. FABRICATED MAIN CARGO FLOOR PANEL 252XLF IAW EO B7567-5320-9692-H.SDR IPXA12571061Floor Panel · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO COMPARTMENT FLOOR PANEL 252XBF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR FDEA201201120131Floorboard · delaminatedFLOORBOAR 251YG COMPOSITE MATERIAL SEPARATING, 8 IN LONG, UPP SURFACE. FABRICATED REPLACEMENT PANEL 251 YG IAW DWD SRZ 25-005, REV J.SDR FDEA201201120130Floorboard · crackedFLOORBOARD 252WH CRACKED AT UPPER SURFACE 1 EA. FABRICATED REPLACEMENT PANEL 252 WH IAW DWG SRZ 25-005, REV J.SDR FDEA201201120129Floorboard · crackedFLOORBOARD 252 UH CRACKED AT UPPER SURFACE 3 EA. FABRICATED REPLACEMENT PANEL 252 UH IAW DWG SRZ 25-005, REV J.SDR FDEA201201120128Floorboard · crackedFLOORBOARD 252PH CRACKED AT UPPER SURFACE 3 EA. FABRICATED REPLACEMENT PANEL 252 PH IAW DWG SRZ 25-005, REV J.SDR FDEA201201120127Floorboard · crackedMAIN CABIN FLOOR PANEL 251 BH HAS 3 EA CRACKS AT CLEVIS CUT OUT. FABRICATED REPLACEMENT PANEL 251BH IAW DWG SRZ 25-005, REV J.SDR FDEA201201120126Floorboard · crackedFLOORBOARD 252YG, CRACKED AT UPPER SURFACE 1 EA. FABRICATED REPLACEMENT PANEL 252YG IAW DWG SRZ 25-005, REJ.SDR FDEA201201120125Floorboard · crackedFLOORBOARD 252ZF, CRACKED AT UPPER SURFACE 2 EA. FABRICATED REPLACEMENT PANEL 252ZF IAW DWG SRZ 25-005, REV J.SDR FDEA201201120124Floorboard · delaminatedFLOODBOARD 251UH COMPOSITE MATERIAL SEPARATED AT UPPER SURFACE AROUND CLEVIS CUT-OUT, FABRICATED FLOORBOARD PANEL 251UH IAW DWG NR SRZ 25-005, REV J.SDR FDEA201201120123Floorboard · damagedFLOORBOARD 242EK HAS 4 AREAS THAT ARE CRUSHED, WHERE CLEVIS ATTACHES, FABRICATED FLOORBOARD 242EK IAW DWG SRZ 25-005, REV J.SDR FDEA201201120105Floor Panel · delaminatedFORWARD CARGO COMPARTMENT FLOOR PANEL NR 131YF FOUND DELAMINATED. R & R IAW AMM 53-10-29-04, REV 52.1. NEW FLOOR PANEL 131YF FABRICATED IAW DWG SRZ-25-005, REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 113.SDR FDEA201201120103Floor Panel · damagedFWD CARGO COMPARTMENT FLOOR PANEL NR 131JG, FOUND DAMAGED. R & R AMM 53-10-29-04, REV 52.1. NEW FLOOR PANEL 131JG FABRICATED IAW DWG SRZ-25-005 REVISION J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201201120102Floor Panel · damagedFWD CARGO COMPARTMENT FLOOR PANEL NR 132JG FOUND DAMAGED. R & R IAW AMM 53-10-29-04, REV 52.1. NEW FLOOR PANEL 132JG FABRICATED IAW DWG SRZ-25-005, REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201201120101Floor Panel · damagedFWD CARGO COMPARTMENT FLOOR PANEL NR 131QF FOUND DAMAGED. R & R AMM 53-10-29-04, REV 52.1. NEW FLOOR PANEL 131QF FABRICATED IAW DWG SRZ-25-005, REV J. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 113.SDR USAA2012011200002Floor Panel · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR PANEL 271LF BETWEEN FR74 TO FR75, -Y2462. REPLACED FLOOR PANEL 271LF IAW A330 SRM 51-42-11.SDR USAA2012011200001Floor Panel · corrodedS2 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR PANEL 271LF BETWEEN FR74 TO FR75, Y2462. REPLACED FLOOR PANEL 271LF IAW A330 SRM 51-42-11.SDR IPXA12571237Floorboard · corrodedINSPECTION TYPE:C-CK, LAVATORY FLOORBOARD HAS AREAS OF DAMAGED, CORRODED INSERTS AND CORRODED/ MISSING NUTPLATES FOR ANGLE FITTING. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR USAA2012011100023Floor Panel · delaminatedS2 CHECK - DELAMINATION ON FLOOR PANEL 262GG BETWEEN FR60 TO FR62 & BETWEEN -Y953 TO -Y1456. REPLACED FLOOR PANEL 262GG IAW A330 SRM 53-02-00.SDR USAA2012011200015Floor Panel · delaminatedS2 CHECK - DELAMINATION ON FLOOR PANEL 252EF BETWEEN FR37 TO FR37.4 & BETWEEN -Y2462 TO -Y1959. REPLACED FLOOR PANEL 252EF IAW A330 SRM 53-02-22 FIG 211.SDR IPXA12571097Floorboard · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO FLOORBOARD 252 XCF DELAMINATED. FABRICATED NEW MAIN CARGO FLOORBOARD 252 XCF IAW EO B757-5320-9692-H.SDR IPXA12571077Floorboard · delaminatedINSPECTION TYPE:C-CHECK, MAIN CARGO FLOORBOARD 251 XRF DELAMINATED. FABRICATED NEW MAIN CARGO FLOORBOARD 251 XRF IAW EO B757-5320 -9692-H.SDR IPXA12571075Floorboard · delaminatedINSPECTION TYPE:C-CK, MAIN CARGO FLOORBOARD PANEL 251XHF DELAMINATED. FABRICATED NEW MAIN CARGO FLOORBOARD PANEL 251XHF IAW EO B757-5320-96 92-H.SDR IPXA12571073Floor Panel · damagedINSPECTION TYPE:C-CK, FLIGHT DECK ENTRY FLOOR PANEL EDGE DAMAGE AND DAMAGED INSERTS. FABRICATED FLIGHT DECK ENTRY FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12571063Floor Panel · damagedINSPECTION TYPE:C-CHECK, FLIGHT DECK ENTRY FLOOR PANEL HAS EDGE DAMAGE AND DAMAGED INSERTS. FABRICATED FLIGHT DECK ENTRY FLOOR PANEL IAW EO B757-5320-9692-H.
Back to JASC 5321