SDR IPXA1168015Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 241VM IS CRACKED AT AFT END ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 241VM IAW EO A300-5320-42721-A, PARA 6A.SDR IPXA1168013Floorboard · puncturedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 231WG HAS A HOLE ON LOWER SURFACE. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD 3231WG IAW EO A300-5320-42721-A, PARA 6A.SDR IPXA1167978Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 231XG IS CRACKED IN 2 PLACES. FABRICATED MAIN CABIN FLOORBOARD NR 231XG IAW EO A300-5320-40552-A, APPENDIX B.SDR FDEA201107142711Floor Panel · damagedFLOOR PANEL 242UJ HAS 3 EA AREAS CRUSHED, 42 SQ INCHES TOTAL. FABRICATED REPLACEMENT PANEL 242 UJ, REFERENCE DWG SRZ 25-005 REV J.SDR IPXA1567926Floor Panel · damagedINSPECTION TYPE:C-CK, FLOOR PANEL 241XBF DAMAGED IN SEVERAL PLACES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR DALA1143623244Floor Panel · delaminatedAFT CARGO COMPT FLOOR PANEL 161AF IS DELAMINATED AND HAS MULTIPLE DENTS ON UPPER SKIN. REMOVED, FABRICATED, AND INSTALLED NEW PNL 161AF IAW A320 AMM 53-42-14-400-001.SDR FDEA201107142712Floor Panel · crackedFLOOR PANEL 241WH HAS 1 EA, 10 INCH CRACK. FABRICATED REPLACEMENT FLOOR PANEL 241WH, IAW DWG SRZ 25-005, REV J.SDR FDEA201107142710Floor Panel · damagedFLOOR PANEL 232XH HAS 3 EA CRUNCHED AREAS, 24 SQ IN TOTAL.SDR FDEA201107142709Floor Panel · crackedFLOOR PANEL 242QJ HAS 3 EA, 8 INCH CRACKS. FABRICATED FLOOR PANEL 242QJ IAW DWG SRZ -25 -005, REV J.SDR FDEA201107142708Floor Panel · crackedFLOOR PANEL 252GF HAS 1 EA, 12 INCH CRACK.SDR FDEA201107142702Floor Panel · damagedOFF ACFT PART--FLOOR PANEL 242EK HAS 6 EA CRUSHED AREAS FABRICATED NEW PANEL 242EK IAW DWG SRZ-25-005, REV J.SDR FDEA201107142700Floor Panel · crackedFLOOR PANEL 231QH HAS 1 EA 10 IN CRACK FABRICATED NEW FLOOR PANEL 231QH IAW DWG SRZ 25-5-005, REV J.SDR FDEA201107142699Floor Panel · crackedFLOOR PANEL 232LT HAS 2 EA. 10 IN CRACKS FABRICATED NEW FLOOR PANEL 232LH IAW DWG SRZ 25-5-005, REV J.SDR FDEA201107142698Floor Panel · crackedFLOOR PANEL 252PH HAS 2 EA. 12 IN. CRACKS FABRICATED NEW FLOOR PANEL 252PH IAW DWG SRZ 25-5-005 REV J.SDR FDEA201107142697Floor Panel · crackedFLOOR PANEL 252BF HAS 1 EA, 10 IN CRACK, FABRICATED NEW PANEL 252BF IAW DWG SRZ 25-5-005, REV J.SDR FDEA201107142694Floor Panel · damagedOFF ACFT PART--FWD CARGO FLOOR PANEL 131YF HAS 14 SQ IN EDGE DAMAGE AND 6 IN CRACK, FABRICATED NEW PANEL 131YF IAW DWG SRZ 25-5-005 REV J.SDR USAA2011072500029Floor Panel · delaminatedC11 CHECK - DELAMINATION ON FLOOR PANEL ASSEMBLY AT R1 DOOR BETWEEN FR16 TO FR20 & BETWEEN -Y1292 & -Y1732, Z240. REPLACED FLOOR PANEL ASSEMBLY AT R1 DOOR IAW A320 SRM 51-74-00.SDR IPXA11168134Floorboard · delaminatedINSPECTION TYPE:5YR, FWD CARGO FLOORBOARD NR 131BH IS DELAMINATED IN 2 PLACES FABRICATED FWD CARGO FLOORBOARD NR 131BH IAW EO A300-5320-16407-E, APPENDIX C.SDR IPXA1168058Floor Panel · crackedINSPECTION TYPE:5YR, FLOOR PANEL 252YH IS CRACKED. REPAIRED FLOOR PANEL 252YH EO A300-5320-42721-A.SDR IPXA1168052Floor Panel · crackedINSPECTION TYPE:5YR, MDCC FLOOR PANEL 252VJ IS CRACKED. REPAIRED FLOOR PANEL 252VJ IAW EO A300-5320-42721-A.SDR IPXA1168042Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 251YJ IS CRACKED AT LOWER SURFACE. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 251YJ IAW EO A300-5320-42721-A, PARA 6A.SDR IPXA1168031Floorboard · crackedINSPECTION TYPE:5YR MAIN CABIN FLOORBOARD NR 252UJ IS CRACKED ON LOWER SURFACE. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 252UJ IAW EO A300-5320-42721-A, PARA 6A.SDR IPXA1168028Floorboard · brokenINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 252WG IS BROKEN. FABRICATED MAIN CABIN FLOORBOARD NR 252WG IAW EO A300-5320-40552-A, APPENDIX B.SDR IPXA1168014Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 251VJ IS CRACKED AT LOWER SURFACE. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 251VJ IAW EO A300-5320-42721-A, PARA 6A.SDR IPXA1168012Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 251UJ IS CRACKED AT LOWER SURFACE. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 251UJ IAW EO A300-5320-42721-A, PARA 6A.SDR IPXA1167979Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 252ZG HAS CRACKS ON LOWER SURFACE. FABRICATED MAIN CABIN FLOORBOARD NR 252ZG IAW EO A300-5320-40552-A, APPENDIX B.SDR IPXA1567919Floor Panel · damagedINSPECTION TYPE:C-1, MAIN CARGO COMPARTMENT FLOOR PANEL 232XEF DAMAGED. FABRICATED FLOOR PANEL IAE EO B757-5320-969392-G.SDR FDEA201107132672Floor Panel · crackedFLOOR PANEL 251RH HAS 1EA, 10 INCH CRACK. FABRICATED REPLACEMENT PANEL 251RH IAW DWG SRZ-25-005, REV J AND IDENTIFIED REPLACEMENT PANEL IAW GMM 7-0-1001.SDR IPXA11168133Floorboard · puncturedINSPECTION TYPE:5YR, CARGO FLOORBOARD NR 161HF IS PUNCTURED. FABRICATED FLOORBOARD NR161HF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA1168029Floorboard · puncturedINSPECTION TYPE:5YR, BULK CARGO FLOORBOARD NR162HF IS PUNCTURED. FABRICATED BULK CARGO FLOORBOARD NR 162HF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA11168252Floor Panel · crackedINSPECTION TYPE:10YR, MAIN DECK FLOOR PANEL 241LJ CRACKED IN 2EA PLACES ON LOWER SURFACE. REPAIRED MAIN DECK FLOOR PANEL 241LJ REF EO A300-5320-42721-A AND SRM 53-10-20-201, REV 20, PARA 8.B, FIG 203 (SHT 2).SDR IPXA11168250Floor Panel · crackedINSPECTION TYPE:10YR, MAIN DECK FLOOR PANEL 241LT CRACKED ON LOWER SURFACE. REPAIRED MAIN DECK FLOOR PANEL 241LT REF EO A300-5320-42721-A AND SRM 53-10-20-201, REV 20, FIG 203.SDR IPXA11168129Floorboard · delaminatedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD 231KJ IS DELAMINATED ON UPPER SURFACE FABRICATED MAIN CABIN FLOORBOARD NR 231KJ IAW EO A300-5320-40552-A, APPENDIX B.SDR IPXA1567920Floor Panel · damagedINSPECTION TYPE:C-1, EXTENSIVE EDGE DAMAGE TO MAIN CARGO FLOOR PANEL 231XDF. REPLACED PANEL 231XDF IAW EO B757-5320-9692-G.SDR IPXA11567910Floor Panel · damagedINSPECTION TYPE:C-1, MAIN CARGO COMPARTMENT FLOOR PANEL 231XGF DAMAGED. FABRICATED FLOOR PANEL IAW EO B757-5320-96392-G.SDR IPXA11567908Floorboard · damagedINSPECTION TYPE:C-1, MAIN CARGO COMPARTMENT FLOORBOARD NR 232XGF HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOORBOARD NR 232XGF HAS EDGE DAMAGE.SDR IPXA11567866Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 231XFF HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL 231XFF IAW B757-5320-9692-G.SDR IPXA11567862Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 232XHF HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL 232XHF IAW B757-5320-9692-G.SDR IPXA11567861Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 242XGF HAS SEVERAL EDGE DAMAGES. FABRICATED REPLACEMENT FLOOR PANEL 242XGF IAW B757-5320-9692-G.SDR IPXA11568285Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 480 TO 560, LBL 45 TO 65 MULTIPLE AREAS WORN THROUGH ON UPPER SURFACE FROM BALL MATS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G, DATED 04-15-2009.SDR IPXA11568267Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 560 TO 620, LBL 45 TO 65 MULTIPLE AREAS WORN THROUGH ON UPPER SURFACE FROM BALL MATS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G, DATED 04-15-2009.SDR IPXA11568234Floorboard · damagedINSPECTION TYPE:C3 FLOORBOARD AT STA 560 TO 620 LBL 45 TO 65 MULTIPLE AREAS WORN THROUGH ON UPPER SURFACE FROM BALL MATS. FABRICATED REPLACEMENT FLOORBOARD EO B757-5320-9692-G, DATED 04-15-2009.SDR IPXA11568233Floorboard · damagedINSPECTION TYPE:C3 FLOORBOARD AT STA 480 TO 560, LBL 45 TO 65 MULTIPLE AREAS WORN THROUGH ON UPPER SURFACE FROM BALL MATS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G, DATED 04-15-2009.SDR IPXA11568206Floorboard · damagedINSPECTION TYPE:C3, MCB FLOORBOARD 1420 TO 1540, RBL 45 TO RBL 60 HAS DAMAGED FASTENER HOLE 26" FROM AFT END OTBD SIDE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11568154Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 880 TO 900, LBL 45 TO 65 FWD EDGE IS DAMAGED. REPLACED FLOORBOARD IAW SRM 53-00-50-0I 1, SRM 53-00-50-1A 1, AMM 53-01-01-4, EO B757-5320-9692-G.SDR IPXA11568114Floorboard · damagedINSPECTION TYPE:C3, MCB FLOORBOARD STA 1320 TO 1420, BL0 TO RBL25 AFT OTBD CORNER IS DAMAGED. R & R FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11568113Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 620 TO 720, RBL 45 TO 65 IS DAMAGED AND MISSING INSERTS. R & R FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1568082Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 560 TO 620, LBL 25 TO 45 MULTIPLE AREAS WORN THROUGH ON UPPER SURFACE FROM BALL MATS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692.SDR IPXA1568081Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 820 TO 720, LBL 45 TO 65 INBD EDGE IS DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA1568080Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 480 TO 560, LBL 25 TO 45 IS DAMAGED AND MISSING INSERTS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692.
Back to JASC 5321