JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA1568079Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 720 TO 780 RBL 45 TO 65 IS DAMAGED AND MISSING INSERTS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692.SDR IPXA1568041Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 480 TO 560, RBL 25 TO 45 IS DAMAGED. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692.SDR IPXA1568038Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 560 TO 620 RBL 0 TO 25 IS DAMAGED AND MISSING INSERTS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692.SDR IPXA1568036Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 880 TO 820 LBL 45 TO 65 FWD EDGE IS DAMAGED. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692.SDR IPXA1568034Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 560 TO 620, LBL 0 TO 25 MULTIPLE AREAS WORN THROUGH ON UPPER SURFACE FROM BALL MATS. FABRICATED REPLACEMENT FLOOR PANEL EO B757-5320-9692.SDR IPXA1568026Floorboard · delaminatedINSPECTION TYPE:C3, FLOORBOARD STA 820-880, RBL 45-65 IS DAMAGED/DELAMINATED AND MISSING INSERTS. FABRICATED REPLACEMENT FLOORBOARD A 402H IAW EO B757-5320-9692-G.SDR IPXA1568025Floorboard · delaminatedINSPECTION TYPE:C3, FLOORBOARD AT STA 620-720 LBL 25-45 IS DAMAGED/DELAMINATED AND MISSING INSERTS. FABRICATED REPLACEMENT FLOORBOARD FROM A 402H IAW EO B757-5320-9692-G.SDR IPXA1568024Floor Panel · wornINSPECTION TYPE:C3, FLOORBOARD AT STA 480 TO 560 LBL 25 TO 45 MULTIPLE AREAS WORN. R & R FLOORBOARD IAW SRM 53-00-50-1A1, EO B757-5320-9692-G, SRM 53-00-50-0I1.SDR IPXA1568023Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA. 560 TO 620 RBL 25 TO 45 IS DAMAGED. R & R FLOOR PANEL IAW SRM 53-00-50-1A1 AND EO B757-5320-9692-G, SRM 53-00-50-0I1.SDR IPXA1568022Floor Panel · wornINSPECTION TYPE:C3, FLOORBOARD AT STA 480 TO 560 LBL 0 TO 25 MULTIPLE AREAS WORN THROUGH ON UPPER SURFACE FROM BALL MATS. R & R FLOORBOARD IAW SRM 53-00-50-0I1, 53-00-50-1A1 AND EO B757-5320-9692-G.SDR IPXA1567998Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 880 TO 900 RBL 45 TO 65 IS DAMAGED AND MISSING INSERTS. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G, SRM 53-00-50-0I-1, SRM 53-00-50-1A1.SDR IPXA1567995Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD 1600 TO 1680, BL0 TO RBL 25 IS DAMAGED AT AFT END. R & R FLOOR PANELS IAW EO B757-5320-9692-G, MM 53-01-01-4.SDR IPXA1567963Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 333 TO 440, RBL 0 TO 25 IS DAMAGED AND MISSING. REPLACED FLOORBOARD IAW SRM 53-00-50-1A 1 AND EO B757-5320-9692-G.SDR IPXA1567962Floorboard · damagedINSPECTION TYPE:C3 FLOORBOARD AT STA 820 TO 880, RBL 0 TO RBL 25 IS DAMAGED AND MISSING INSERTS. FABRICATED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1567961Floor Panel · damagedINSPECTION TYPE:C3, FLOORBOARD AT STA 880 TO 900 RBL 0 TO 25 IS DAMAGED AND MISSING INSERTS. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A 1, AMM 53-01-01-4, AND EO B757-5320-9692-G.SDR IPXA11567865Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 231XLF HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL 231XLF IAW B757-5320-9692-G.SDR IPXA11567863Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 232XNF HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL 232XNF IAW B757-5320-9692-G.SDR IPXA11567860Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR PANEL 232XMF HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL 232XMF IAW B757-5320-9692-G.SDR IPXA1B67807Floor Panel · damagedFLOOR PANEL, AT STA 1700 POS 17L MULTIPLE DAMAGES. FABRICATED NEW FLOOR PANEL USING BMS4-17, TYPE 2 FLOORBOARD, REF DRAWING 146U5877.SDR IPXA1B67806Floor Panel · damagedFLOOR PANEL AT STA 1760 POS 18L MULTIPLE DAMAGES. FABRICATED NEW FLOOR PANEL USING BMS4-17 TYPE 1 FLOORBOARD, REF DWG 65B23345, D455166 CLEARED.SDR IPXA1B67804Floor Panel · damagedMAIN DECK FLOOR PNL STA 1982, DAMAGED REF EO B747-5320-4 2973-A NR 2 DAMAGED HAS 2 HOLES MEASURING .5 IN DIA WITH 1 IN SEPARATION. REPAIR FLR PNL IAW SRM 53-00-51, REPAIR 1, 4D.SDR IPXA1B67803Floor Panel · damagedMAIN DECK FLOOR PNL, STA 1982, DAMAGED REF EO B747-5320-42973-A NR 3 HOLE 0.5 DIA LOCATED 3 IN AFT OF SECOND DAMAGED AND 6 IN FROM OUTBD EDGE REPAIRED FLR PNL DAMAGE IAW SRM 53-00-50, REPAIR 1, 4C.SDR IPXA1B67802Floor Panel · damagedMAIN DECK FLOOR PANEL STA 1982 DAMAGED REF EO B747-532 0-42973-A NR 4 DAMAGED AREA HAS 4 HOLES 0.25 IN DIA AND ARE 1.5 APART DISBONDING 8.0 X 4 AREA REPAIRED FLOOR PANEL IAW SRM 53-00-50, REPAIR 1 4F.SDR IPXA1B67801Floor Panel · damagedMAIN DECK FLOOR PANEL AT STA 1982, DAMAGED REF EO B747- 5320-42973-A NR 6 DAMAGE HAS HOLE 0.75 IN DIA 6 IN FROM 5TH DAMAGED AREA AND 3.5 IN FROM OTBD EDGE. REPAIRED FLOOR PANEL IAW SRM 53-00-50, REPAIR 1, 4C.SDR IPXA1B67800Floor Panel · damagedMAIN DECK FLOOR PANEL DAMAGED REF EO B747-5320-42973-A NR7 DAMAGED AREA IS 1X0.5 HOLE MINOR GORE DAMAGE LOCATED 4 IN AFT OF 6TH DAMAGED AREA 6 IN FROM OTBD EDGE. REPAIR FLR PANEL IAW SRM 53-00-50, REPAIR 1 4C.SDR IPXA1B67799Floor Panel · damagedMAIN DECK FLOOR PANEL STA 1982 DAMAGED REF EO B747-532 0-42973-A 1ST DAMAGE AREA HAS 3 HORS IN A 2X1 IN AREA. REPAIRED IAW SRM 53-00-50, REPAIR 1 4D.SDR IPXA1B67798Floor Panel · damagedMAIN DECK FLOOR PANEL STA 1982, DAMAGED REF EO B747-5320-429 73-A NR2 HOLES MEASUREING 0.5 DIA WITH 1'' SEPARATION. REPAIR IAW SRM 53-00-51, REPAIR 1, 4D.SDR IPXA1B67797Floor Panel · damagedFLOOR PANEL STA 1767, RBL 95 HAS HOLE 1.5" X .75". LOCATED 1.5" FROM OTBD EDGE. REPAIRED IAW EO B747-5320-42967-A AND SRM 53-50-51 REPAIR 1.SDR IPXA1B67796Floor Panel · damagedFLOOR PANEL STA 290 LBL 36 HAS HOLE IN SKIN 3" X .3" 9" FROM FWD END OF PANEL. REPAIRED IAW EO B747-5320-42963-A AND SRM 53-00-51 REPAIR 1.SDR IPXA1B67795Floor Panel · damagedFLOOR PANEL STA 2127, LBL 87 HAS HOLE IN UPPER SKIN 1.5" FROM OTBD EDGE AND 27" FROM FWD END. REPAIRED IAW EO B747-5320-42968-A AND SRM 53-00-51 REPAIR 1.SDR IPXA1B67794Floor Panel · crackedINSPECTION TYPE:N/A MCD FLOOR PANEL STA 1761 LBL 36 CRACKED WITH DELAMINATION. REPAIRED IAW EO B747-5320-42965-A AND SRM 53-00-51, REPAIR 1.SDR IPXA1B67793Floor Panel · crackedCRACK WITH DELAMINATION FLOOR PANEL STA 919, LBL 25. REPAIRED IAW EO B747-5320-42972-A AND SRM 53-00-51, REPAIR 1.SDR IPXA1B67792Floor Panel · crackedFLOOR PANEL STA 1679, LBL 46 HAS CRACK WITH DEBOND. REPAIRED IAW EO B747-5320-42969-A AND SRM 53-00-51.SDR IPXA1168272Floor Panel · crackedINSPECTION TYPE:4C, Z31 ZONE FLOOR PANEL 231PH HAS CRACK IN LOWER SURFACE OF HONEYCOMB PANEL. FABRICATED FLOOR PANEL 231PH REF EO A300-5320-40552-A APPX A/B.SDR IPXA1168271Floor Panel · delaminatedINSPECTION TYPE:10YR, 231 ZONE FLOOR PANEL 231KJ IS DELAMINATED IN 3 PLACES ON LOWER SURFACE. FABRICATED FLOOR PANEL 231KJ REF EO A300-5320-40552-A APPX A/B.SDR IPXA11568284Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE AND MISSING INSERT BS 1600-1680 LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA11568139Floor Panel · corrodedINSPECTION TYPE:C-CHECK, LT FLIGHT DECK COMPARTMENT CORROSION FOUND ON FLOOR DECK FWD, INBD CAPT SEAT TRACK. REMOVED CORROSION AND RESTORED FINISH IAW EA 110839.SDR IPXA1568091Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL HAS EDGE DAMAGE AND MISSING INSERT BS 1600-1680, LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA1568078Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE BS 1540-1600 LBL LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA1568077Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS DELAMINATION ON LWR SURFACE BS 1420-1540, LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA1568076Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS DAMAGED INSERT BS 1320-1420 LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA1568021Floor Panel · puncturedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS PUNCTURE ON LWR SURFACE AND DAMAGED INSERT BS 1420-1540, BL 0 TO LBL 25. FABRICATED NEW MCB FLOOR PANEL IAW EO B757-5320-9692-G, SRM 53-00-50-1A 1, SRM 53-00-50-0I 1.SDR IPXA1568019Floorboard · delaminatedINSPECTION TYPE:C3, FLOOR PANEL HAS DELAMINATION ON LOWER SURFACE BS 1540-1600, BL0-LBL25. FABRICATED REPLACEMENT FLOOR PANEL A 402H IAW EO B757-5320-9692-G.SDR IPXA1568018Floorboard · puncturedINSPECTION TYPE:C3, MCB FLOORBOARD HAS PUNCTURE ON LOWER SURFACE BS 1320-1420, BL 0- LBL 25. FABRICATED REPLACEMENT FLOORBOARD, A 402H IAW EO B757-5320-9692-G.SDR IPXA1567960Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS EDGE DAMAGE BS 1200-1320 BL 0 TO LBL 25 FABRICATED PANEL IAW EO. NR B757-5320-9692.SDR IPXA11567891Floor Panel · damagedINSPECTION TYPE:C-CK, FLOOR PANEL NR 231XEF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11567864Floor Panel · damagedINSPECTION TYPE:C-CK, MAIN CARGO FLOOR PANEL 251XBF HAS 2 EDGE DAMAGED. FABRICATED REPLACEMENT PANEL 251XBF IAW EO B757-5320-9692-G.SDR IPXA11567822Floor Panel · damagedINSPECTION TYPE:C=CK, MAIN CARGO FLOOR PANEL 242XCF HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL 242XCF IAW EO B757-5320-9692-G.SDR IPXA1568290Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 1681 TO BS 1720 BL 0 TO LBL 55 HAS SEVERAL DAMAGED INSERTS AND DELAMINATION ON LWR SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G, DATED 04-15-2009.SDR IPXA1568289Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 1681 TO BS 1720 BL 0 TO RBL 55 HAS DELAMINATION ON LWR SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G, DATED 040-15-2009.
Back to JASC 5321