JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1119409870Floor Panel · corrodedCOCKPIT FLOOR PANEL 15 HAS CORROSION. REMOVED CORROSION IAW DC09 SRM 51-10-3 & CPP 5100-01570-01. ORIGINAL THICKNESS .040 REMOVED .02 REMAINING .038 IN LIMITS IAW DC-9 SRM 53-01TOOL H8332.2 EA AREAS KNIFE EDGED & REQUIRE REPAIR. REPAIRED IAW DC9 SRM 53-01 USDR IPXA11665647Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 6 PUNCTURES AND 7 DENT MARKS AT STA 893 TO 932 RBL 77 TO RBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR IPXA11665646Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 5 PUNCTURES AND 9 DENT MARKS AT STA 1114 TO 1197+22 LBL 11 TO RBL 11. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR IPXA11665645Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 4 PUNCTURES AND 6 DENT MARKS AT STA930 TO 975 LBL11" TO RBL11". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR IPXA11665644Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 6 PUNCTURES AND 5 DENT MARKS AT STA731 TO 764 L77 TO L88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-06.SDR IPXA11665643Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 7 PUNCTURES AND 6 DENTS MARKS AT BS 412 TO 540 RBL 33 TO RBL 55. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-06.SDR IPXA11565483Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 560 TO 620, LBL 46 TO LBL 61, EXPOSED COMPOSITES AND PUNCTURES. REPLACE PANEL IAW EO B757-5320-9692-G.SDR IPXA11565456Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 1100 TO 1180 LT SIDE DELAMINATED ON BOTTOM AND INSERTS CORRODED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565455Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD, AT STA 1060- STA 1100, LBL 45 TO LBL 61 INSERTS BROKEN OUT, INSERTS CORRODED EDGE DAMAGE. REPLACE FLOORBOARD IAW EO B757-5320-9692-GSDR IPXA11565454Floorboard · crushedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 1681 TO STA 1720 EDGE DAMAGE, CRUSHED AND CRACKED. RT SIDE REPLACE FLOORBOARD IAW BO B757-5320-9692-G.SDR IPXA11565452Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 560 TO 620 LBL 26 TO LBL 45 HAS EXPOSED COMPOSITES. REPLACE FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565451Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 720 TO 780 RBL 46 TO RBL 61 HAS SEVERAL BAD INSERTS AND BROKEN CORNER. REPLACE FLOORBOARD IAW B757-5320-9692-G.SDR IPXA11565450Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 480 TO 560, RBL 26 TO RBL 45 HAS AREAS OF DELAMINATION. REPLACE PANEL IAW EO B757-5320-9692-G.SDR IPXA11565448Floorboard · crushedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 1320-STA 1420, LBL 45.5 TO LBL 61, CRUSHED AT AFT END AND SEVERAL INSERTS CORRODED. REPLACE PANEL IAW EO B757-5320-9692-G.SDR IPXA11565446Floorboard · crushedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 1100 TO STA 1180 BL 0 TO RBL 25 FWD EDGE CRUSHED. REPLACE FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565445Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 900 TO 1020, LBL 1 TO LBL 26 HAS EDGE DAMAGE. REPLACE FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565444Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 440 TO 480, LBL 26 TO LBL 45 HAS DELAMINATION AND PUNCTURES. REPLACE FLOORBOARD IAW EO B757-5320-9692-G.SDR FDEA201103150988Floor Splice · corrodedFWD CARGO COMPT FLOOR DECK PLATE SPLICE STRAPS AT STA 653.8 AND STA 749.4 FOUND WITH CORROSION. CORRODED SPLICE STRAPS R & R IAW AMM 25-50-04 REV 97. REPAIR IS CLASSIFIED AS MINOR.SDR FDEA201103150987Floor Splice · corrodedAFT CARGO COMPT FLOOR DECK PLATE SPLICE STRAPS AT STA 1468, STA 1508 AND STA 1328 FOUND WITH CORROSION. CORRODED SPLICE STRAPS R & R IAW AMM 25-50-04, REV 97. REPAIR IS CLASSIFIED AS MINOR.SDR DALA1119259870Floor Panel · corrodedMAIN CABIN FLOOR PNL 83 HAS CORROSION ON BOTTOM SIDE AROUND FASTENER HOLES. REMOVED FLOOR PNL 83, FOUND TO BE OUT OF LIMITS. FABRICATED AND INSTALLED REPAIRS IAW DC-9 SRM 51-30-1.SDR DALA1119249870Floor Panel · corrodedMAIN CABIN FLOOR PNL HAS CORROSION ON TOP OF PNL. REMOVED, FABRICATED, AND INSTALLED DOUBLERS IAW DC9 SRM 51-30-2.SDR DALA1119123215Floor Panel · delaminatedFWD CARGO FLOOR PANEL 131AF DELAMINATED. REMOVED AND REPLACED FLOOR PANEL WITH NEW FABRICATED PANEL PER AMM 53-22-14.SDR DALA1119113215Floor Panel · delaminatedAFT PIT FLOOR PANEL 151DF IS DELAMINATED 10X 3 INCH AREA. REMOVED AND REPLACED FLOOR PANEL WITH NEW FABRICATED PANEL PER MM 53-42=14 PB401.SDR DALA1119083215Floor Panel · damagedAFT PIT FLOOR PANEL 151LF HAS SEVERAL PUNCTURES AND IS DELAMINATED, 6 X 4 INCH AREA. REMOVED FLOOR PANEL 151LF IAW AMM53-42-14-000-001. FABBED NEW PANEL IAW STAM TRAVELER T11/874678 BATCH 1886727 IAW DWG 3D25 -37705. INSTALLED PANEL IAW MM 53-42-14 PB401.SDR DALA1118963114Floor Panel · damagedFWD CARGO COMPT FLOOR PANEL 131CG HAS FWD AND AFT EDGES BROKEN. FABRICATED FWD CARGO FLOOR PANEL 131CG ON STAM TRAVELER T11/873429 IAW DWG 3D25-40532, MATERIAL A402AB-60X144 BATCH 1910500.SDR DALA1118953114Floor Panel · damagedCOMPARTMENT, FLOOR PANEL 151PE HAS EDGE DAMAGE, CRACKS AND DENTS. FABRICATED AFT CARGO FLOOR PANEL 151PE ON STAM TRAVELER T11/873411 IAW DWG 3D25-40532, MATERIAL A402AB-60X144 BATCH 1910500.SDR DALA1118943114Floor Panel · damagedAFT CARGO COMPARTMENT, FLOOR PANEL 161NF HAS MULTIPLE DENTS, EDGE DAMAGES, CRACKS AND FILLER REPAIRS FABRICATED AFT CARGO FLOOR PANEL 161NF ON STAM TRAVELER 873413 IAW DWG 3D25-40532, MATERIAL A402AB-60X144 BATCH 1910500.SDR DALA1118933114Floor Panel · damagedAFT CARGO COMPARTMENT, FLOOR PANEL 151ZG HAS EDGE DAMAGE, DENTS, PUNCTURE AND DELAMINATION. FABRICATED AFT CARGO FLOOR PANEL 151ZG ON STAM TRAVELER T11/ 873400 IAW DWG 3D45-40532, MATERIAL A402AB-60X144 BATCH 1910500.SDR IPXA1665460Floor Panel · damagedDURING A/C UNLOAD POSITION, 11R LT SIDE CTR BUTTERFLY LOCK FLOOR PANEL DAMAGED AND SIDE LOCK DAMAGED. FLOOR PANEL R & R TO S/M SHOP. THIS IS A MAJOR REPAIR TRANSFERRED TO NRC 338942. INSPECTED AREA. INSTALLED NEW FLOOR PANEL IAW MM 53-01-06-4. FLOORBOARD ISDR IPXA11565636Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT BS 297-333 BL 0 - RBL 60 HAS DAMAGE TO INSERTS AND EDGES. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692G.SDR IPXA1565392Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT BS 297-333 BL 0- RBL 60 HAS DAMAGE TO INSERTS & EDGES. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR USAA2011031591062Floor Panel · delaminatedCWF - C1 - MAJOR REPAIR - DELAMINATION ON CABIN FLOOR PANEL 161CF BETWEEN FR67 TO FR36, S43, -Z1956. REPLACED CABIN FLOOR PANEL 161CF BETWEEN FR67 TO FR36, S43, -Z1956 IAW A330 SRM 51-02-00.SDR IPXA1665768Floor Panel · damagedHOLE IN FLOOR OF MAIN DECK IN POSITION 4L DEFER IAW EO B767-5320-27379. IDENTIFIED AS A MAJOR REPAIR. REMOVED PANEL AT POSITION 4L AND TRANSFERRED TO NRC 446041. FABRICATED REPLACEMENT FLOOR PANEL IAW AMM 53-01-06-4. THIS CLEARS D449012.SDR IPXA1665742Floor Panel · damagedMCD FLOOR PANEL 5L 2ND FROM INBD DAMAGED. DEFER IAW EO B767-5320-27879. DEF 449013 ASSIGNED. FABRICATED NEW FLOOR PANEL AND REPLACED IAW EO-B767-5320-9693-H. OK FOR SERVICE.SDR IPXA11565637Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440 RBL, 45-65. FABRICATED NEW MCB FLOOR PANEL IAW EO 5320-9692-G.SDR IPXA11565631Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440, LBL 1-25. FABRICATED FLOOR PANEL IAW EO B757-5320-9692G.SDR IPXA11565477Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440, LBL 25-45. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565473Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440, RBL 1-25. FABRICATED REPLACEMENT FLOOR PANEL IAW EO 757-5320-9692-G.SDR IPXA1565380Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440, LBL 45-65. FABRICATED NEW FLOOR PANEL IAW B757-5320-9692-G.SDR USAA2011031491055Floor Panel · delaminatedCWF - C1 - MAJOR REPAIR - DELAMINATION ON CABIN FLOOR PANEL 252ZF BETWEEN FR40 TO FR42 & BETWEEN -Y1456 TO -Y1959. REPAIRED CABIN FLOOR PANEL 252ZF BETWEEN FR40 TO FR42 & BETWEEN -Y1456 TO -Y1959 IAW A330 SRM 53-02-00.SDR USAA2011031491054Floor Panel · delaminatedCWF - C1 - MAJOR REPAIR - DELAMINATION ON CABIN FLOOR PANEL 251MF BETWEEN FR39 TO FR40 & BETWEEN Y450 TO Y953. REPAIRED CABIN FLOOR PANEL 251MF BETWEEN FR39 TO FR40 & BETWEEN Y450 TO Y953 IAW A330 SRM 53-02-00.SDR USAA2011031491036Floor Panel · debondedCWF - C1 - MAJOR REPAIR - DISBONDING ON CABIN FLOOR PANEL 162EF BETWEEN FR69 TO FR72 & BETWEEN Y=0 TO Y700. REPLACED CABIN FLOOR PANEL 162EF BETWEEN FR69 TO FR72 & BETWEEN Y=0 TO Y700 IAW MCGILL IRM 9701 REV G.SDR USAA2011031491035Floor Panel · debondedCWF - C1 - MAJOR REPAIR - DISBONDING ON CABIN FLOOR PANEL 232DG BETWEEN FR26.4 TO FR27 & BETWEEN -Y1456 TO -Y1959. REPAIRED CABIN FLOOR PANEL 232DG BETWEEN FR26.4 TO FR27 & BETWEEN -Y1456 TO -Y1959 IAW A330 SRM 53-02-00.SDR IPXA11565607Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 880-900 LBL 1-25 HAS MISSING INSERTS, EDGE DAMAGE AND A LOOSE ATTACH PLATE. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G & EO B757-5100-33281-C.SDR IPXA11565604Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 720-820 RBL 1-24 HAS A MISSING INSERT. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G & B757-5100-33281-C.SDR IPXA11565603Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 880-900, RBL 1-25 HAS MISSING INSERTS, EDGE DAMAGE AND A LOOSE ATTACH PLATE. FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G & EO B757-5100-33281-C.SDR IPXA11565517Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 720-820, LBL 26-44 HAS EDGE DAMAGE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1, EO B757-5320-9692-G, B757-5100-33281-C.SDR IPXA11565516Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 560-620 LBL 46-62 HAS EDGE DAMAGE AND DELAMINATION. FABRICATED NEW MCB FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11565499Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 820-880, LBL 46-62 HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11565490Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 720-820, LBL 46-62 HAS 2 MISSING INSERTS AND EDGE DAMAGE. FABRICATED NEW FLOOR PANEL.
Back to JASC 5321