JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA11564904Floorboard · delaminatedINSPECTION TYPE:C3, MAIN CARGO DECK FLOORBOARD BS 1540-1600, RBL 45-61, SIDE EDGES ARE DELAMINATED AND PUNCTURED AT OTBD MIDEDGE AREA. R & R FLOORBOARD IAW EO B757-5100-33281-C, SRM 53-00-50-1A1, B757-5320-9692-G.SDR IPXA11564893Floorboard · damagedINSP TYPE:C3, FLOOR PNL BS 720-820, RBL 0-25 HAS EDGE DAMAGE. REPLACED FLOOR PANEL IAW EO B757-5320-9692; B757-5100-33281-C.SDR IPXA11564892Floorboard · damagedINSP TYPE:C3, FLOORBOARD HAS EDGE DAMAGE AT BS 1020 TO BS 1057, LBL 25-LBL 45. FOUND FLOORBOARD DAMAGE TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOORBOARD BS 1020-1057, LBL 25-45 IAW EO B757-5320-9692-G.SDR IPXA11564891Floorboard · damagedINSP TYPE:C3, FLOORBOARD HAS EDGE DAMAGE AND CRACKED INSERTS BS 1100-1200, LBL 0-25. REPLACED FLOOR PANEL IAW EO B757-5320-9692, B757-5100-33281-C.SDR IPXA11564890Floorboard · damagedINSP TYPE:C3, FLOORBOARD HAS EDGE DAMAGE AT BS 1020 TO 1057, LBL 0-LBL 25. FOUND FLOORBOARD DAMAGE TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11564889Floorboard · delaminatedINSP TYPE:C3, MAIN CARGO DECK FLOORBOARD, BS 1540-1600, RBL 45-61 SIDE EDGES ARE DELAMINATED AND PUNCTURED AT OTBD MID EDGE AREA. R & R FLOORBOARD IAW EO B757-5100-33281-C, SRM 53-00-50-1A1, B757-5320-9692-G.SDR IPXA11564888Floorboard · damagedINSP TYPE:C3, MCB FLOORBOARD AT BS 720-780 RBL 45-65 HAS EDGE DAMAGE. FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOORBOARD BS 720-780, RBL 45-65 IAW EO B757-5320-9692-G.SDR IPXA11564887Floorboard · damagedINSP TYPE:C3, FLOORBOARD HAS EDGE DAMAGE AT BS 1057, RBL 25 FLOORBOARD FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT IAW EO B757-5320-9692-G.SDR IPXA11564886Floorboard · damagedINSPECTION TYPE:C3, MAIN CARGO BAY FLOORBOARD BS 879-900, BL 0, RBL, WL 208 HAS THE TAB COMING LOOSE. FOUND FLOORBOARD AT BS 879-900 BL 0.0 TO BE OUT OF LIMITS, FABRICATED REPLACEMENT IAW EO B757-5320-9692-G.SDR IPXA11564885Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 1200-1320 LBL 0-25 HAS DAMAGED INSERTS AND EDGE DAMAGE. FOUND DAMAGE TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11564884Floorboard · puncturedINSPECTION TYPE:C3, MCB FLOORBOARD BS 1200-1320, LBL 25-45 HAS EDGE DAMAGE AND IS PUNCTURED. FOUND PUNCTURE TO BE OUT OF LIMITS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11564864Floorboard · delaminatedINSPECTION TYPE:C3, FLOORBOARD HAS EDGE DAMAGE AND DELAMINATION AT BS 1057 TO 1100, RBL 25-45. REPAIRED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11564834Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 1600-1680, LBL 0-25 HAS EDGE DAMAGE. R & R WITH NEW FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11564833Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 1320-1420, LBL 0-25 HAS EDGE DAMAGE. R & R WITH NEW FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11564832Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 1320-1420, LBL 25-45 HAS EDGE DAMAGE. R & R WITH NEW FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11564830Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 1600-1680 RBL 25-45 HAS EDGE DAMAGE. R & R WITH NEW FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.SDR UALA2011021800834Floor Panel · corrodedMAIN CABIN FLOOR AT STA 1680 BL-0 TO LBL-18 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION ON DECK PLATE. OUT OF LIMITS. INSTALLED DOUBLER REPAIR EA PD 57-53-083. THIS IS A CAT A REPAIR NR 2455N00291.SDR DALA1111763228Floor Panel · puncturedFWD CARGO COMPARTMENT FLOOR PANEL 131AF HAS A PUNCTURE AND DELAMINATION. REMOVED PANEL 131AF IAW AMM 53-22-14-000-001. FABRICATED NEW FLOOR PANEL 131AF ON STAM TRAVELER T11/870830 IAW DWG 3D25-37498. INSTALLED PANEL IAW AMM 53-22-14-400-001.SDR DALA1111743228Floor Panel · puncturedFWD CARGO COMPARTMENT, FLOOR PANEL 131EF HAS PUNCTURES AND EDGE DELAMINATIONS. REMOVED PANEL 131EF IAW AMM 53-22-14-000-001. FABRICATED ON STAM TRAVELER T11/870851 IAW D25-37498. INSTALLED PANEL 131EF IAW AMM 53-22-14-400-001.SDR IPXA11565181Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 620-720, LBL 45-65 HAS EDGE DAMAGE AND UPPER SURFACE HAS DENT. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G, DWG 143N5457, AND SRM 53-00-50-2R1.SDR DALA1115609877Floor Panel · crackedFLOOR PANEL NR 63 HAS CRACKS ON THE EDGE OF FLOOR PANEL. REMOVED 2 EA CRACKS IN FLOOR IAW SRM 53-01. FABRICATED 2 EA REPAIR DOUBLERS IAW SRM 53-23-0. TREATED & PRIMED IAW SRM 51-10-3, PG 3. INSTALLED REPAIR DOUBLER IAW SRM 5 3-01. DETECTED NO CRACKS AT 2 SDR IPXA1565101Floor Panel · delaminatedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL, BS 560-620, BL 0-RBL 25 2 CORNER DELAMINATED, UPPER SURFACE HAS NUMEROUS FIBER DAMAGE. REMOVED AND FABRICATED MAIN CARGO BAY FLOOR PANEL BS 560-620, BL 0- RBL25 IAW EO B757-5320-9692-G, SRM 53-00-50-2R.SDR IPXA1565100Floor Panel · delaminatedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL BS 560-620 BL0-25LBL, CORNER DELAMINATED AND EDGE DAMAGE. FABRICATED MAIN CARGO BAY FLOOR PANEL BS 560-620, BL0-25, LBL IAW EO B757-5320-9692-G, SRM 53-00-50-2R1.SDR IPXA1565064Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL AT BS 480-560, RBL 25-45 HAS BROKEN INSERTS AND DELAMINATED CORNERS. REPLACED IAW EO B757-5320-9692-G.SDR IPXA1565049Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL AY BS 720-820, RBL 25-45, HAS EDGE DAMAGE AND DELAMINATED CORNER. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR USAA2011030490972Floor Panel · debondedCWF - C1 - MAJOR REPAIR - DISBONDING ON CABIN FLOOR PANEL 232UF AT FR25 & BETWEEN -Y1959 TO -Y2462. REPAIRED CABIN FLOOR PANEL 232UF AT FR25 & BETWEEN -Y1959 TO -Y2462 IAW A330 SRM 53-02-00.SDR USAA2011030490971Floor Panel · debondedCWF - C1 - MAJOR REPAIR - DISBONDING ON CABIN FLOOR PANEL 231UF AT FR25 & BETWEEN Y2462 TO Y1959. REPAIRED CABIN FLOOR PANEL 231UF AT FR25 & BETWEEN Y2462 TO Y1959 IAW A330 SRM 53-02-00.SDR USAA2011030490970Floor Panel · debondedCWF - C1 - MAJOR REPAIR - DISBONDING ON CABIN FLOOR PANEL 232LF AT FR22 & BETWEEN -Y450 TO -Y953. REPAIRED CABIN FLOOR PANEL 232LF AT FR22 & BETWEEN -Y450 TO -Y953 IAW A330 SRM 53-02-00.SDR USAA2011030490969Floor Panel · debondedCWF - C1 - MAJOR REPAIR - DISBONDING ON CABIN FLOOR PANEL 231QF AT FR25 & BETWEEN -Y450 TO Y450. REPAIRED CABIN FLOOR PANEL 231QF AT FR25 & BETWEEN -Y450 TO Y450 IAW A330 SRM 53-02-00.SDR USAA2011030490968Floor Panel · debondedCWF - C1 - MAJOR REPAIR - DISBONDING ON CABIN FLOOR PANEL 231MF AT FR22 & BETWEEN Y953 TO Y1456. REPAIRED CABIN FLOOR PANEL 231MF AT FR22 & BETWEEN Y953 TO Y1456 IAW A330 SRM 53-02-00.SDR USAA2011030490967Floor Panel · debondedCWF - C1 - MAJOR REPAIR - DISBONDING ON CABIN FLOOR PANEL 231NF AT FR22 & BETWEEN Y1456 TO Y1959. REPAIRED CABIN FLOOR PANEL 231NF AT FR22 & BETWEEN Y1456 TO Y1959 IAW A330 SRM 53-02-00.SDR IPXA1565037Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL AT BS 440-480, RBL 45-65 HAS BROKEN INSERT, DAMAGED EDGE AND DELAMINATED CORNER. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1, FIG 101.SDR IPXA1565027Floorboard · damagedINSPECTION TYPE:C3, MCB FLOORBOARD, BS 333-440, LBL 45-65, UPR SURFACE HAS AREA OF FIBER DAMAGE. FOUND FLOORBOARD TO BE OUT OF LIMITS IAW SRM 53-00-50-1A1. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692G.SDR IPXA1565015Floorboard · delaminatedINSPECTION TYPE:C3, FLOORBOARD HAS EDGE DAMAGE AND DELAMINATION AT BS 1057, LBL 25 TO LBL 45 (MARKED). FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM 53-00-50-1A1. FABRICATED REPLACEMENT FLOORBOARD FROM BS 1020-1060, LBL 25-45 IAW EO B757-5320-9692-G. APPLIED SAFESDR IPXA1565014Floorboard · delaminatedINSPECTION TYPE:C3, MAIN CARGO DECK, FLOORBOARD BS 1420-1540, RBL 0-RBL 25, INBD SIDE EDGE HAS AREAS OF DELAMINATION AND MISSED DRILLED HOLES ON UPPER SURFACE. FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM 53-00-50-1A1. FABRICATED REPLACEMENT FLOOR PANEL FROM BSSDR IPXA1565013Floorboard · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 440-480 LBL 45-65 CORNER IS DELAMINATED. FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM 53-00-50-1A1. FABRICATED REPLACEMENT FLOOR PANEL FROM BS 440-480 LBL 45-65 IAW EO B757-5320-9692-G. APPLIED SAFETY WALK IAW EO B757-51SDR IPXA1565011Floorboard · delaminatedINSPECTION TYPE:C3, FLOORBOARD DELAMINATED AT BS 480-560, RBL 45-65. REPLACED IAW EO B757-5320-9692.SDR IPXA1565010Floorboard · delaminatedINSPECTION TYPE:C3, FLOORBOARD DELAMINATED AT BS 480-560, RBL 0-25. REPLACED IAW EO B757-5320-9692.SDR IPXA1564970Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT BS 720-820, LBL 45-65 IS DAMAGED. REPLACED IAW EO B757-5320-9692.SDR IPXA1564969Floorboard · delaminatedINSPECTION TYPE:C3, FLOORBOARD AT BS 480-560, LBL 0-25 IS DELAMINATED. REPLACED IAW EO B757-5320-9692.SDR IPXA1564964Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL BS 620-720, RBL 45-65 IS DAMAGED. REPLACED FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA1564963Floor Panel · delaminatedINSPECTION TYPE:C3, FLOOR PANEL BS 560-620, RBL 45-65 IS DELAMINATED. REPLACED FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA1564961Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 333-440 BL 0-RBL 25 HAS EDGE DAMAGE AND UPPER SURFACE HAS AREAS OF FIBER DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO NR B757-5320-9692-G.SDR IPXA1564960Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 620-720, BL 0-LBL 25 HAS AREA OF EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO NR B757-5320-9692G.SDR IPXA1564959Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL AT BS 620-720 RBL 0-25 HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO NR B757-5320-9692G.SDR IPXA1564942Floor Panel · delaminatedINSPECTION TYPE:C3, MCB FLOOR PANEL AT BS 480-560 LBL 45-65 HAS DELAMINATED CORNERS. R & R FLOOR PANEL AT BS 480-560 LBL 45-65 IAW SRM 53-00-50-1A1.SDR IPXA1564941Floor Panel · delaminatedINSPECTION TYPE:C3, FLOOR PANEL DELAMINATED BS 560-620, LBL 45-65. REPLACED IAW EO B757-5320-9692.SDR IPXA1564925Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD BS 720-820 LBL 25-45 HAS EDGE DAMAGE AND CORNER IS DELAMINATED. R & R WITH FLOORBOARD FABRICATED IAW EO B757-5100-33281-C.SDR IPXA1564924Floor Panel · dentedINSPECTION TYPE:C3, MCB FLOOR PANEL AT BS 333-440 RBL 25-45 IS PUNCTURED AND DENTED. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11564903Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL AT BS 720-820, RBL 0-25, HAS EDGE DAMAGE. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G; EO B757-5100-33281-C.
Back to JASC 5321