SDR IPXA11564902Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL BS 620-720, LBL 25-45 HAS NUMEROUS AREAS OF EDGE DAMAGE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1, FIG 101.SDR IPXA11564901Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL AT BS 720-780, RBL 45-65, EDGE DAMAGE. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11564895Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD, BS 620-720, LBL 25-45 HAS NUMEROUS AREAS OF EDGE DAMAGE. FOUND DAMAGE TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11564894Floorboard · delaminatedINSP TYPE:C3, FLOORBOARD AT BS 780-820, RBL 45-65 HAS EDGE DAMAGE AND DELAMINATED CORNER. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G TO REPLACE OUT OF LIMITS DAMAGE ON ORIGINAL FLOORBOARD.SDR IPXA11564883Floorboard · puncturedINSPECTION TYPE:C3, MCB FLOORBOARD BS 560-620, RBL 25-45, UPR SURFACE IS PUNCTURED & CRACKED. FOUND PUNCTURE TO BE OUT OF LIMITS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11564831Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL, BS 440-480, LBL 25-45 HAS EDGE DAMAGE. R & R WITH NEW FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1564819Floorboard · damagedINSPECTION TYPE:C3 FLOOR PANEL EDGE DAMAGE. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1565288Floor Panel · damagedINSPECTION TYPE:C4, EXPOSED CORE ON MAIN DECK FLOOR PANEL 232 MF. REPLACED PANEL 232 MF IAW EO B757-5320-9692-G.SDR IPXA1565282Floorboard · brokenINSPECTION TYPE:C4, FLOORBOARD INSERT BROKEN OUT, PANEL NR 231 XEF. REPLACED FLOORBOARD NR 231XEF IAW EO B757-5320-9692-G.SDR IPXA1164930Floorboard · delaminatedINSPECTION TYPE:10YR, FWD CARGO PIT FLOORBOARD NR 132FE IS DELAMINATING AT CORNER AND SKIN IS GOUGED. FABRICATED FWD CARGO FLOORBOARD NR 132FE IAW EO A300-5320-16407-E, APPENDIX C.SDR ASAA1159097Floor Panel · crackedAFT CARGO NR 2 FLOOR PANEL IS CRACKED. REMOVED CRACKED FLOOR PANEL FABRICATED AND INSTALLED REPLACEMENT PART IAW BOEING DWG 453A2610 AND B737 800 SRM 53 60 53 51 40 02 51 40 08 51 20 01 AND BOEING SOPM 20 41 02.SDR USAA2011021690764Floor Panel · delaminatedPIT - MAJOR REPAIR - C11/SY6 CHECK - CABIN FLOORBOARD AT FR 16 - FR 20, -Y765 HAS DELAMINATION. REPLACED CABIN FLOORBOARD AT FR 16 - FR 20, -Y765 IAW THE MCGILL IRM 9701 G.SDR FDEA201102140565Floorboard · corrodedBULK CARGO COMPARTMENT FLOORBOARD 162 HF METAL TOP IS CORRODED. REMOVED TOP SHEET IAW DWG SRZ 25-011, REV "C". TOP SHEET MATERIAL ID 2024-T3 IAW DWG SRZ 25-011, REV "C". FABRICATED TOP SHEET IAW DWG SRZ 25-011, REV "C". BONDED TOP SHEET TO FLOORBOARD IAWSDR DALA1114239877Floor Panel · damagedFLOOR PANEL NR 62 HAS 5 HOLES THAT ARE OVERSIZED. 5 EA SCREW HOLES WORN BEYOND LIMITS IAW NWA SRM 53-01. FABRICATED REPAIR DOUBLER TREATED AND PRIMED IAW NWA ARM 51-10-3. INSTALLED REPAIR DOUBLER IAW NWA SRM 53-01, ON FLOOR PANEL 62.SDR IPXA1564813Floor Panel · delaminatedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS DELAMINATED ON UPPER SURFACE BS 1016-1055, LBL 25-45. FABRICATED REPLACEMENT FLOOR PANEL IAW EO 757-5320-9692-G.SDR IPXA1564812Floor Panel · delaminatedINSPECTION TYPE:C2, FLOOR PANEL NR 242XDF AFT EDGE DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1564811Floor Panel · delaminatedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS DELAM ON UPPER SURFACE BS 1020-BS 1055, LBL 45-60. FABRICATED REPLACEMENT PANEL IAW EO 757-5320-9692-G.SDR DALA1110449873Floor Panel · damagedMAIN CABIN METAL FLOOR PANEL 60B HAS ELONGATED HOLES AND 2EAHAT CHANNELS CHAFED. BLENDED HAT CHANNELS OUT OF LIMITS IAW SRM 53-01 FIG 1. FABRICATED 2EA HAT CHANNEL SPLICES. CUT AND TRIMMED 2EA HAT CHANNELS. INSTALLED 2EA HAT CHANNELS AND SPLICES IAW SRMSDR DALA1110439873Floor Support · crackedMAIN CABIN STATION 237 AT L18L FLOOR PANEL SUPPORT CRACKED. REMOVED AND REPLACED SECTION OF SUPPORT ZEE ANGLE IAW DC9 A-53-2 0-01-801-663A-A. NEW ZEE ANGLE 2EA SPLICE FABRICATED IAW DC9A-53-20-01-801-663A-A P226.SDR DALA1110429873Floor Panel · crackedMAIN CABIN METAL FLOOR PANEL 60A 1EA HAT CHANNEL CRACKED AND CORNER SKIN CRACKED. CUTOUT DAMAGED SECTION OF HAT CHANNEL IAW DC9 SRM 51-10-2. FABRICATED, LOCATED AND DRILLED HAT CHANNEL AND REPAIR SPLICE IAW DC9 SRM 53-05 FIG 1. CUTOUT DAMAGE OF FLOOR PANELSDR DALA1110419873Floor Panel · damagedMAIN CABIN METAL FLOOR PANEL 102C HAS CORROSION AROUND FASTENER HOLES, 2EA HAT CHANNELS CRACKED AND END SKIN TORN. REMOVED CORROSION IAW SRM 53-01 FIG 1 ORIGINAL MATERIAL .032" REMOVED .002 FOUND TO BE WITHIN LIMITS IAW SRM 53-01 FIG 1. REMOVED DAMAGED AREASSDR IPXA1B64730Floor Panel · damagedFLOOR PANEL DAMAGED, POS 8L. FABRICATED NEW FLOOR PANEL IAW EO B747-5320-41448-A.SDR IPXA11166801Floor Panel · crackedINSPECTION TYPE:10YR, FLOOR PANEL 252LM IS CRACKED. FABRICATED NEW FLOOR PANEL 252LM IAW EO A300-5320-40552-A.SDR DALA1110399857Floor Panel · crackedMAIN PASSENGER CABIN FLOOR PANEL 41 HAS APPROX 10EA CRACKS. FOUND FLOOR PANEL 41 UNREPAIRABLE. FABRICATED NEW PANEL. IDENTIFIED PANEL AS PERMANENT STENCILED PANEL "NOT FOR RESALE" PER ERA 488345-14 AND DC9 SRM 51-10-3.SDR DALA1117209877Floor Panel · corrodedFLOOR PANEL 79 HAS CORROSION ON NUMEROUS SCREW HOLES. BLENDED OUT NUMEROUS SCREW HOLES OF CORROSION, FOUND TO BE OUT OF LIMITS IAW DC9 SRM 53-01. FABBED FLOOR PNL SKIN, IAW DC9 SRM 51-10-4. INST HAT CHANNELS TO FLOOR PNL 79 SKIN IAW DC9 SRM 51-30-02, REMOVSDR DALA1116429877Floor Panel · corrodedFLOOR PANEL NR 79 HAS CORROSION ON NUMEROUS SCREW HOLES. BLENDED OUT NUMEROUS SCREW HOLES OF CORROSION & FOUND TO BE OUT OF LIMITS IAW SRM 53-01. FABRICATED FLOOR PANEL 79 SKIN IAW SRM.SDR USAA2011021490752Floor Panel · corrodedBFM - MAJOR REPAIR - S2 CHECK - CORROSION ON FLOOR PANEL 222GF. REPLACED FLOOR PANEL 222GF IAW A330 SRM 51-75-12.SDR USAA2011021490751Floor Panel · corrodedBFM - MAJOR REPAIR - S2 CHECK - CORROSION ON FLOOR PANEL 271KF. REPLACED FLOOR PANEL 271KF IAW A330 SRM 51-75-12.SDR DALA1110389857Floor Panel · damagedMAIN PAX CABIN FLOOR PANEL 81 HAS SEVERAL ELONGATED FASTENERS HOLES AT FWD FLANGE BS 851. REMOVED PANEL FOUND UNREPAIRABLE. FABRICATED ALODINED AND PRIMED NEW FLOOR PANEL APPLIED STENCIL & ID TAG 'P' PER ERA 488732-14 INSTALLED PANEL.SDR DALA1110379857Floor Panel · crackedMAIN PAX CABIN FLOOR PANEL 60D HAS 3EA CRACKS AT RIVET HOLES AND PULLED THROUGH RIVETS BS 674. REMOVED FOUND TO BE UNREPAIRABLE FABRICATED ALODINED AND PRIMED NEW FLOOR PANEL. APPLIED STENCIL & ID TAG 'P' PER ERA 488739-14 INSTALLED PANEL 60D.SDR DALA1110369857Floor Panel · damagedMAIN PASSENGER CABIN FLOOR PANEL 101 AFT END 3EA ELONGATED HOLES. FABRICATED NEW FLOOR PANEL 101 FROM ER/A 488734-14. LOCATED DRILLED COUNTERSINK HOLES IAW DC9 SRM 51-10-2, 51-10-3, 51-30-2 & ER/A 488734-14.SDR DALA1110359857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL 84 HAS CORROSION AROUND FASTENER HOLES. REMOVED CORROSION FOUND PANEL TO BE OUT OF LIMITS IAW DC9 SRM 53-01 FIG 1. ORG THICKNESS IS .025 IAW DWG PL9957919. REMOVED, .016.009 REMAINS. FABRICATED NEW PANEL AND HAT CHANNEL DRSDR DALA1110349857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL 5 HAS CORROSION ON SKIN. REMOVED CORROSION IAW DC9 SRM 53-01 FIG 1 SHT 3 OUT OF LIMITS. FABRICATED IAW DWG 9957808 FABRICATED DRILLED DEBURRED & INSTALLED IAW DWG 9957808 & ER/A 488726-14.SDR DALA1110339857Floor Panel · tornMAIN PAX CABIN FLOOR PANEL 60B HAS 1EA TEAR AND SEVERAL PULL THROUGH RIVETS BS 617. REMOVED FLOOR PANEL IAW DC9 SRM 51-30-5. PANEL FOUND TO BE BEYOND REPAIR. OBTAINED MATERIAL TO FABRICATE NEW PANEL PER ER/A 488738-14 DRILLED PANEL AND HAT CHANNELS UP IAW DSDR FDEA201102110537Floor Panel · corrodedFLOOR PANEL BETWEEN STA 1681 TO 1720 HAS VARIOUS AREAS OF CORROSION ON SKIN FROM RBL 62 - LBL 62. REMOVED CORROSION AT FLOOR PANEL BETWEEN STA 1681-1720 RBL 62-LBL62 IAW SRM 51-10-02. BLENDED 3EA AREAS OUT OF LIMITS IAW SRM 53-60-51, FIG 201, REPAIR 2. ORISDR DALA1117229877Floor Panel · damagedFLOOR PANEL 65 HAS A CORNER BROKEN. FABRICATED REPAIR DOUBLER FOR FLOOR PANEL 65 IAW SRM 53-01, PG 25. TREATED & PRIMED IAW SRM 51-10-3, PG 31, FASTENER INSTALLATION IAW SRM 51-30-2.SDR DALA1116089877Floorboard · corrodedMAIN CABIN FLOORBOARD NR 26 HAS CORROSION ON TOP SURFACE. UPON FURTHER INSP, FOUND MATERIAL LOSS AROUND CUPHOLDER FROM CORROSION, WEB IS OUT OF LIMITS REF SRM 53-01. REMOVED INSERT IN CUP HOLDER HOLE, AS WELL AS HAT CHANNELS FILLER, REF SRM 31-30-2, PG 1-13.SDR DALA1114529877Floor Panel · corrodedMAIN CABIN FLOOR PANEL NR 25 HAS CORROSION ON TOP SURFACE. REMOVED CORROSION IAW AMM 51-21-03-701-929A -A, PG 2-11, FOUND TO BE OUT OF LIMITS IAW SRM 53-01-00, PG 8, FIG 1 SHEET 3. REMOVED FLOOR PANEL IAW SRM 51-30-02, PG27, FIG 19. FABRICATED FLOOR PANEL, SDR DALA1114519877Floorboard · crackedFLOOR BOARD NR 66 HAS A CORNER BROKEN. REMOVED DAMAGE IAW SRM 53-01, PG 2, FIG 4, NDT FOR CRACKS, FABRICATED DOUBLER REPAIR IAW SRM 41-30-2, PG 1 AND 2, SRM 53-01, PG 25, FIG 4, SHEET 4. FAB FILLER REPAIR 7075-T6 IAW SRM 53-01, PAGE 25, .025, TREATED AND PRISDR DALA1114509877Floorboard · crackedREPAIR LOCATED AT THE EDGE OF THE FLOORBOARD NR 75 IS DISBONDED AND HAS A CRACK IN THE BACKSIDE. REMOVED DAMAGED AREA AND TRIM OUT, HFEC SURFACE INSP PER NDT SPM 06-10-01.001, NO CRACK ON CUT OUT AREA. FAB DOUBLER, .032, AND REPAIR FILLER .025, APPLIED ALODSDR DALA1114499877Floor Panel · crackedFLOOR BOARD PANEL NR 74 HAS A HOLE CRACKED AND ANOTHER CRACK BESIDE. REMOVED DAMAGE ON FLOOR PANEL IAW SRM 53-01, PG 25, FIG 4. FABRICATED DOUBLER 7075-T6 .032, FABRICATED FILLER REPAIR, 7075-T6 .025, IAW SRM 53-01, PG 25, FIG 4, STEP 2, AND SRM 53-23-0, PGSDR DALA1112479877Floor Panel · crackedFLOOR PANEL NR 78 HAS 2 SCREW HOLES WITH CRACKS EXTENDING TO EDGE OF PANEL. TRIMMED OUT DAMAGED AREA IAW DC-9 SRM 53-00-01, PG 25, FIG 4, STEP 1 FABRICATED REPAIR PARTS, TREATED AND PRIMED IAW DC-9 SRM 53-23-0, PG 8, FIG 5, ANS SRM 51-10-03, PG 5. INSTALLED SDR DALA1112419877Floor Panel · crackedFLOOR PANEL 60A UNDERSIDE SUPPORTS ARE CRACKED AT EDGES. REMOVED UNDERSIDE SUPPORTS CRACKED ON FLOOR PANEL 60A IAW DC9 SRM 51-30-2, PG 28. HAT CHANNELS FOUND TO BE OUT OF LIMITS. OK TO FABRICATE IAW NWA DC9 SRM 53-05, PG 9. HAT CHANNELS IAW NWA DC9 SRM 51-SDR IPXA1564772Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO FLOOR PANEL MISSING INSERTS BS 1320-1420, LBL 25-45. FABRICATED NEW BOARD IAW EO 757-5320-9692-G.SDR DALA1109959873Floor Panel · tornCABIN FLOOR PANEL 94 SKIN TORN AT FWD END. RECEIVED NEW FLOOR PANEL LOCATED, DRILLED AND C-SUNK IAW SRM 51-10-04.SDR DALA1109929857Floor Panel · crackedMAIN PASSENGER CABIN FLOOR PANEL NR 75 HAS 1EA CRACKED AT INBD FLANGE AND 1EA ELONGATED HOLE BS775, CORRECTED. FABRICATED FLOOR PANEL 75..SDR DALA1109919857Floor Panel · crackedMAIN CABIN METAL SKIN FLOOR PANEL NR 60A HAS 4 EA HAT CHANNELS CRACKED. FABRICATED FLOOR PANEL 60A IAW ER/A 488737-14 REV ORG P214, CORRECTED.SDR DALA1109909873Floor Panel · corrodedMAIN CABIN METAL FLOOR PANEL NR 78, 1EA END HAS CORROSION AND 1EA PUNCTURED HOLE PARTS, RACK 22B BLENDED LIGHT CORROSION BY HAND ORIGINAL IS .025 NO METAL LOST IAW SRM 51-10-3. REMOVED PUNCTURED AREA IAW SRM 51-10-4. NDT VERIFIED CRACK IS REMOVED IAW NDT SDR DALA1117319223Floor Panel · crackedHMV2 CABIN FLOOR PANEL CRACKED PNL NR 221XF. PANEL REPAIR PER SRM 51-10-03 AND TIMCO DWG 09T229MO42.SDR IPXA1564727Floorboard · damagedINSPECTION TYPE:C1, MAIN CARGO FLOORBOARD. BS 560-620, LBL 45-65 HAS MISSING INSERT. REPLACED FLOORBOARD ASSY IAW EO B757-5320-9692-G, SRM 53-00-50-1A1.
Back to JASC 5321