JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA1564719Floor Panel · delaminatedINSPECTION TYPE:C1 MAIN CARGO FLOOR PANEL BS 338-440 RBL 25 IS DELAMINATED AND HAS MISSING INSERTS. REPAIRED IAW EO B757-5320-9692-G, DATED: 04/15/2009.SDR IPXA1564718Floor Panel · delaminatedINSPECTION TYPE:C1, FLOOR PANEL, BS 333-440 LBL 25, HAS DELAMINATION ON LOWER SURFACE AND A MISSING INSERT. REPAIRED IAW EO B757-5320-9692-G, DATED 04/15/2009.SDR DALA1109539857Floor Panel · corrodedMAIN METAL SKIN FLOOR PANEL, NR 67 HAS CORROSION AROUND EDGES. RECEIVED 1EA NEW FLOOR PANEL NR 67 & IAW SRM 53-23-0. DRILLED UP IAW SRM 51-10-4. INSTALLED, 1EA FLOOR PANEL NR 67. REQUIRED INSP COMPLETED.SDR DALA1109529857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR 63 HAS CORROSION ON OTBD EDGE. RECEIVED FLOOR PANEL NR 63 IAW SRM 53-23-0, FIG 4 INSTALLED 1EA NEW FLOOR PANEL NR 63.SDR DALA1109519857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR 30 HAS CORROSION ON SKIN PREVIOUS REPAIR. REMOVED PANEL NR 30 FROM CABIN FLOOR IAW SRM 51-30-1. FABRICATED FLOOR PANEL NR 30 IAW ER/A 488731-14. INSTALLED FLOOR PANEL NR 30 IAW SRM 51-30-1. REQUIRED INSP COMPLETED.SDR DALA1109509857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR 27 HAS CORROSION ON SKIN. FOUND DAMAGED BEYOND REPAIR IAW SRM 53-01, FIG 1. FABRICATED 1EA FLOOR PANEL IAW DWG 9957919 & ER/A 488729-14. INSTALLED 1EA FLOOR PANEL NR 27 IAW DCARD 0590-0020-8M. REQUIRED INSP COMPLETED.SDR DALA1109499857Floor Panel · bentMAIN PASSENGER CABIN FLOOR PANEL NR 85 IS BENT AT FWD FLANGE, BS 851. REMOVED PANEL NR 85 IAW SRM 51-30-1, CUTOUT DAMAGE IAW SRM 53-05, FIG 2. FABRICATED DOUBLER & FILLER IAW SRM 53-05, FIG 2, INSTALLED DOUBLER & FILLER IAW 53-05, FIG 2. COMPLETED.SDR EOPA020811407ALFloor Panel · delaminatedFLOOR DELAMINATION REQUIRING MAJOR REPAIR.SDR FDEA201102080499Floor Panel · crackedMAIN CABIN FLOOR PANEL 241 YN IN ZONE 240 IS CRACKED. FABRICATED NEW FLOOR PANEL 241 YN IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080498Floor Panel · crackedMAIN CABIN FLOOR PANEL 231 R IN ZONE 230 IS CRACKED. FABRICATED NEW FLOOR PANEL 231 RG IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080497Floor Panel · crackedMAIN CABIN FLOOR PANEL 241 NK IS CRACKED ; ZONE 240. FABRICATED NEW FLOOR PANEL 241 NK IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080496Floorboard · damagedMAIN CABIN FLOORBOARD HAS A BROKEN OFF OTBD FWD CORNER FROM FRAME 25-FRAME 27; RBL 78 TO RBL 100. FABRICATED NEW FLOORBOARD 231 VG IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080495Floor Panel · damagedMAIN CABIN FLOOR PANEL FROM FRAME 40- FRAME 41; LBL 85. FABRICATED NEW FLOOR PANEL 241 VJ IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080494Floorboard · delaminatedAFT CARGO COMPARTMENT FLOORBOARD 152 BF TOP SKIN IS DELAMINATED. FABRICATED NEW FLOORBOARD 152 BF IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080493Skin · crackedAFT CARGO COMPARTMENT FLOORBOARD 152 AF TOP SKIN IS CRACKED. FABRICATED NEW FLOORBOARD 152 AF IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080492Floorboard · damagedAFT CARGO COMPARTMENT FLOORBOARD 151EF TOP SKIN IS TORN AND THE CORNER IS CRUSHED. FABRICATED NEW FLOORBOARD 151 EF IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080491Skin · damagedAFT CARGO COMPARTMENT FLOORBOARD 151 CF FASTENER HOLE IS BROKEN AND THE BOTTOM SKIN IS TORN. FABRICATED NEW FLOORBOARD 151 CF IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080490Floorboard · damagedFWD CARGO COMPARTMENT FLOORBOARD 132 RF, MULTIPLE CORNERS ARE BROKEN, THE EDGES ARE DAMAGED AND MISSING EDGE FILLER. FABRICATED NEW FLOORBOARD 132 RF IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080489Floorboard · crackedFWD CARGO COMPARTMENT FLOORBOARD 131 RF IS CRACKED ON AND THE CORNERS ARE DAMAGED. FABRICATED NEW FLOOR BOARD 131 RF IAW DWG SRZ 25-005, REV "H".SDR FDEA201102080488Floorboard · crackedFWD CARGO COMPARTMENT FLOORBOARD 131 HG IS CRACKED ON THE BACK AND THE EDGE IS BROKEN. FABRICATED NEW 131 HG IAW DWG SRZ 25-005, REV "H".SDR ASOA201100242Floor Panel · corrodedUPPER SURFACE OF PRESSURE FLOOR SKIN HAS SEVERAL AREAS OF CORROSION FROM FS 409+128 TO FS 559 ON RBL 36 TO RBL 47. REPAIRED IAW REO 601R-53-41-1353.SDR ASOA201100241Floor Panel · corrodedUPPER SURFACE OF PRESSURE FLOOR SKIN HAS SEVERAL AREAS OF CORROSION FROM FS 409+128 TO FS 559 ON RBL 36 TO RBL 47. REPAIRED IAW REO 601R-53-41-1354.SDR DALA1109209873Floor Panel · brokenMAIN CABIN METAL FLOOR PANEL NR 61, 1 EA CORNER BROKEN OUT, PARTS RACK 22B. REMOVED DAMAGED AREA IAW SRM 53-01, FIG 4. HFEC INSPECT IAW NDT SPM 06-10-01.001. NO CRACKS NOTED REPAIRED FLOOR PANEL IAW SRM 53-01, FIG 4, 51-10-4, 53-23-0, FIG 4. REQUIRED INSP COMSDR IPXA1565070Floorboard · brokenINSPECTION TYPE:C3, CORNER OF FLOORBOARD IS BROKEN AT BS 1187, LBL 65. REPLACED IAW EO B757-5320-9692-G.SDR IPXA1664737Floor Panel · puncturedINSPECTION TYPE:C, FLOOR PANEL ON FOUND 9EA PUNCTURES AND 3 DENTS MARKS AT STA 975 TO 1114, LBL 11" TO RBL 11". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-06.SDR IPXA1664736Floor Panel · crackedINSPECTION TYPE:C, FLOOR PANEL FOUND CRACK AND WITH 7EA PUNCTURES AT STA 930 TO 975 LBL 11" TO RBL 11". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED AS IAW AMM 53-01-06.SDR IPXA11M64663Floorboard · damagedBULK PIT 3 EA HOLES IN FLOOR. DAMAGE FOUND TO EXCEED LIMITS IN EO MD11-5320-17899-H. FABRICATED 3 NEW FLOORBOARD IAW MD11-5320-34874-B. PANEL CURED, REPAIR COMPLETE REF MD11-5320-34874-B.SDR DALA1109039857Skin · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR 91 HAS CORROSION ON OTBD EDGE. REMOVED & RECEIVED 1EA NEW FLOOR PANEL NR 91. FURNISHED IAW SRM 53-13-0, FIG 4 INSTALLED 1EA NEW FLOOR PANEL NR 91 IAW CARD 0590-4020-8M, CORRECTED.SDR DALA1109029857Skin · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR 83 HAS CORROSION AROUND EDGES. RECEIVED 1EA FLOOR PANEL NR 83 IAW SRM 53-23-0, FIG 4. DRILLED UP IAW SRM 51-10-4. INSTALLED ON CARD 0590-4020-8M. REQUIRED INSP COMPLETED.SDR DALA1109019857Skin · corrodedMAIN METAL SKIN FLOOR PANEL NR 79 HAS CORROSION AROUND EDGES TOP & BOTTOM SURFACE. REMOVED FLOOR PANEL NR 79 IAW SRM 53-13-0, FIG 4, INSTALLED 1EA NEW FLOOR PANEL NR 79 IAW CARD 0590-4020-8M.SDR USAA2011030490974Floor Panel · corrodedBFM - S2 - MAJOR REPAIR - CORROSION ON CABIN FLOOR PANEL 221GF UPPER SURFACE. REPLACED CABIN FLOOR PANEL 221GF UPPER SURFACE IAW TRM 330-5302-11-0330.SDR IPXA1564729Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT STA 440 TO 480 LBL 45-60, DAMAGE FWD END OTBD SIDE MARKED. REPLACED FLOORBOARD IAW EO B757-5320-9692-9 AND SRM 53-00-50-2R1, SRM 53-00-50-1A1.SDR IPXA1564726Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT STA 720-820, LBL 45-60, DAMAGE AT AFT END STA 800 MARKED. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1, TABLE I AND EO B757-5320-9692-G.SDR IPXA1564716Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD DAMAGED MID OTBD SIDE BS 480 TO 560, LBL 25-45. FABRICATED REPLACEMENT FLOORBOARD IAW EO NR B757-5320-9692.SDR IPXA11564655Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT STA 879 TO 900 RBL 45-60, DAMAGED AT FWD END. R & R FLOORBOARD IAW EO 757-5320-9692G.SDR IPXA11564829Floorboard · damagedINSPECTION TYPE:C1, MISSING INSERT IN FLOORBOARD AT STA 1610, RBL44. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1564728Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD STA 1100 TO 1200, BL0 TO RBL 25, FWD END AND OTBD AFT END DAMAGED AND MARKED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G, SRM 53-00-50-1A1.SDR IPXA1564715Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD STA 1100 TO 1200, RBL 25 TO 45, FWD AND AFT ENDS DAMAGED AND MARKED. REPAIRED IAW EO B757-5320-9692-G.SDR IPXA1564698Floorboard · damagedINSPECTION TYPE:C1, MISSING INSERT IN FLOORBOARD AT STA 1590, RBL44. REPLACED MCB FLOORBOARD AT BS 1540-1600, RBL 44, IAW EO B757-5320-96 92-G.SDR DALA1108589864Floor Panel · damagedMAIN CABIN FLOOR PANEL 19 FASTENER HOLES ELONGATED IN FLOOR PANEL RACK. FABRICATED FLOOR PANEL 19 IAW DOUGLAS DRAWING 9957823 AND ER/A 488722-14. REQUIRED INSPECTION COMPLETED.SDR IPXA11564635Floorboard · damagedINSPECTION TYPE:C1 FOUND FLOORBOARD AT STA 1055-1100, RBL 25-45, OTBD SIDE DAMAGED (MARKED) AND MISSING INSERT. R & R WITH FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A, AND EO B757-5320-9692-G.SDR IPXA11564634Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD AT STA 1020-1055, RBL 45-60, AFT END DAMAGED (MARKED). R & R WITH FABRICATED NEW FLOORBOARD ANEL IAW SRM 53-00-50-1A, AND EO B757-5320-9692-G.SDR IPXA11564633Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD AT STA 900-1020, BL 0- LBL 25, FWD CORNER DAMAGED (MARKED). R & R WITH FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A, AND EO B757-5320-9692-G.SDR IPXA11564632Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD AT STA 900-1120, RBL 25-45, FWD CORNER DAMAGED (MARKED). R & R WITH FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A, AND EO B757-5320-9692-G.SDR IPXA11564631Floorboard · damagedINSPECTION TYPE:C1, FOUND FLOORBOARD AT STA 900-1020, LBL 45-60, OTBD SIDE DAMAGED (MARKED). R & R WITH FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A, AND EO B757-5820-9692-G.SDR DALA1108579857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL 59 HAS CORROSION ON END. FABRICATED NEW FLOOR PANEL PER ER/A 488730-14.SDR DALA1108569857Floor Panel · canningMAIN PASSENGER CABIN FLOOR PANEL 64 HAS OIL CAN DAMAGE AT FORWARD END BS 674. CUTOUT DAMAGE 7/8"X5 1/2" HFEC INSPECTED PER NDT SPM FABRICATED DOUBLER AND INSTALLED REPAIR IAW DC9 SRM 53-05 FIG 1.SDR IPXA1564725Floor Panel · dentedINSPECTION TYPE:C1, UPPER FLOOR PANEL IN THE CONTROL CABIN HAS NUMEROUS BROKEN AND CORRODED INSERTS, DENTS AND PUNCTURES. REPLACED CONTROL CABIN UPPER FLOOR PANEL IAW EO B757-5320-9692-G, SRM 53-00-50-2R1, AND SRM 53-00-50-1A1, FIG 101, TABLE I.SDR UALA2011020400594Pressure Panel · corrodedPRESSURE DECK HAS CORROSION AT STA 1682, RBL 56 TO RBL 33. MAJOR REPAIR ACCOMPLISHED: INSTALLED FILLER AND DOUBLER IAW EA PD57-53-072.SDR DALA1108119857Floor Panel · corrodedMAIN CABIN METAL SKIN FLOOR PANEL NR 26 HAS CORROSION ON SKIN. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1. RECEIVED NEW FLOOR PANEL FABRICATED DOUBLER IAW DWG 9957918 TREATED AND PRIMED DOUBLER IAW SRM 51-10-3. INSTALLED DOUBLER TO THE
Back to JASC 5321