SDR WX0A070653Floor Panel · corrodedCABIN FLOOR PANEL STA 200-256 CENTER HAS MULTIPLE AREA OF DAMAGE AND CORRODED INSERTS. FABRICATED NEW FLOOR PANEL IAW MD80 SRM 53-05, PARA 59.SDR WX0A070652Floor Panel · corrodedCABIN FLOOR PANEL STA 160-200 RT HAS MULTIPLE CORRODED INSERTS. FABRICATED NEW FLOOR PANEL IAW MD80 SRM 53-05, PARP 59.SDR WX0A070651Floor Panel · puncturedPASSENGER CABIN RIGHT O/B FLOORBOARD PANEL FS 886 TO 927 HAS MULTIPLE PUNCTURES. REPAIR CABIN FLOORBOARD PANEL IAW DC9/MD80 SRM 53-05 FIG 1, AND SRM 51-30-02 FIG 3.SDR FDEA201010254166Floor Panel · puncturedAFT CARGO PIT FLOOR PANEL LT SIDE AT STA 1841 IS PUNCTURED. FABRICATED NEW FLOOR PANEL IAW DWG SRZ25-005, REV "H" AND DWG SRZ 25-011, REV "C". REMOVED AND RE-INSTALLED FLOOR PANEL IAW SRM 51- 31-01, VOL II.SDR IPXA10663317Floorboard · dentedREF DMI D429161, MAIN CARGO DECK POS NR 2 RT FLOORBOARD - 2ND BOARD IN FROM OTBD HAS A 1-INCH BY 1-INCH DENT. REPLACED FLOORBOARD WORKING WITH EO B767-5320-9693 AND M/M 53-01-06.SDR DALA1028899853Floor Panel · corrodedDURING M-CHECK FOUND CORROSION ON AFT CARGO FLOOR PANEL 2, 3 RIB. REPAIRED PER SRM 51-30-1 PAGE 241.SDR DALA1029349002Stiffener · damagedFLOOR PANEL 826D STIFFENER HAS HOLE, CRACKS, AND CHAFING. REPLACED CHANNEL PER SRM 51-10-04. (DLM88102903)SDR DALA1028759865Floor Panel · crackedDURING M-CHECK FOUND CRACK IN COCKPIT FLOOR PANEL NR 14. REPAIRED PER SRM 53-05 FIGURE 1 PAGE 205.SDR ZZDA2010524Floor Panel · corrodedCABIN FLOOR PANEL, STA 160 TO 200, RBL 48, CORROSION. ACCOMPLISHED FLOOR PANEL REPLACEMENT PER B717 SRM 51-41-02 AND BOEING DRAWING PL9957828.SDR DALA1028769865Stiffener · chafedDURING M-CHECK FOUND CHAFING IN FLOOR PANEL 69 BOTTOM SIDE STIFFENERS IN 4 PLACES. REPAIRED PER SRM 51-10-4.SDR DALA1028603241Panel · damagedDURING L-CHECK FOUND DAMAGE TO CARGO PANEL 131AF. REPLACED PER SRM 53-02-00 FIGURE 205.SDR IPXA10163456Floor Panel · crackedINSPECTION TYPE:5 YR, FLOOR PANEL 232FFIS CRACKED AT LOWER SURFACE AS MARKED. FABRICATED MAIN DECK FLOOR PANEL 232FF REF EO A300-5320-16407, APPX A AND B.SDR IPXA10163455Floor Panel · delaminatedINSPECTION TYPE:5YR, FLOOR PANEL 231KJ DELAMINATED. FABRICATED MAIN DECK FLOOR PANEL 231KJ REF EO A300-5320-16407, APPX A AND B.SDR IPXA10163438Floor Panel · crackedINSPECTION TYPE:5 YR, FWD PIT FLOORBOARD PANEL 131BH HAS A CRACK. FABRICATED LOWER, FWD CARGO COMPT FLOOR PANEL 131BH REF EO A300-5320-16407-E APPX A AND C.SDR IPXA10163436Floor Panel · delaminatedINSP TYPE:5 YR MCD FLOOR PANEL 231GH DELAMINATED. FABRICATED MAIN CARGO DECK FLOOR PANEL 231GH REF EO A300-5320- 16407-E APPX A AND B.SDR IPXA10163412Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD 231WG HAS A CRACK. REPAIRED FLOORBOARD IAW SRM 53-10-20 8B FIG 203 AND EO A300-5320-38221-B.SDR IPXA10163409Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 231XG HAS A CRACK. REPAIRED FLOORBOARD IAW SRM 53-10-20, PARA 8B, FIG 203 AND EO A300-5230-38221-B.SDR IPXA10163407Floor Panel · crackedINSPECTION TYPE:5YR, MCD FLOOR PANEL 251YH IS CRACKED AT FWD EDGE AS MARKED. REPAIRED FLOOR PANEL IAW SRM 53-10-20 PARA 8B, FIG 203 AND EO A300-5320-38221-B.SDR IPXA10163403Floor Panel · crackedINSPECTION TYPE:5YR, MCD FLOOR PANEL 252VJ IS CRACKED AT LOWER SURFACE REPAIRED FLOOR PANEL IAW A300 SRM 53-10-20 PARA 8B, FIG. 203SDR IPXA10163400Floorboard · delaminatedINSPECTION TYPE:5 YR, MAIN CABIN FLOORBOARD 231QJ IS DELAMINATED. FABRICATED FLOORBOARD IAW EO A300-5320-16407-E.SDR IPXA10163399Floor Panel · brokenINSPECTION TYPE:5 YR, MDC FLOOR PANEL 221CG BROKEN. FABRICATED FLOOR PANEL IAW EO A300-5320-16407-E.SDR IPXA10163398Floor Panel · delaminatedINSPECTION TYPE:5 YR, MDC FLOOR PANEL 231PJ DELAMINATED. FABRICATED FLOOR PANEL IAW A300-5320-16407-E.SDR IPXA10163393Floor Panel · crackedINSPECTION TYPE:5 YR, MCD FLOOR PANEL 241HF IS CRACKED AT EDGE. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-16407-E.SDR IPXA10163355Floorboard · delaminatedINSPECTION TYPE:5 YR, MAIN CABIN FLOORBOARD NR 232 AH IS DELAMINATED. REPAIRED FLOORBOARD IAW SRM 53-10-20 PARA 8B, FIG 203, AND EO A300-5320-38221-B.SDR IPXA10163346Floorboard · puncturedINSPECTION TYPE:5 YR, MAIN CABIN FLOORBOARD 231AH HAS A PUNCTURE. REPAIRED FLOORBOARD IAW SRM 53-10-20, PARA 8B, FIG 102. AND EO A300-5320-38221-B.SDR IPXA10163345Floor Panel · crackedINSPECTION TYPE:1C, MCD FLOOR PANEL 232LF IS CRACKED AT LOWER SURVACE AS MARKED. REPAIRED CRACK IAW SRM 53-10-20, FIG 203. SHEET 2 AND EO A300-5320-38221-B.SDR DALA1028389865Floor Panel · damagedDURING M-CHECK FOUND FASTENER HOLES PULLED THROUGH ON MAIN CABIN FLOOR PANEL 61. REPAIRED PER SRM 51-10-4 FIGURE 4, SRM 53-01 FIGURE 4 & SRM 51-30-2.SDR DALA1028359865Floorboard · crackedDURING M-CHECK FOUND CRACK IN MAIN CABIN FLOOR BOARD NR 72. REPAIRED PER SRM 53-05 FIGURE 1 & SRM 51-30-2.SDR DALA1028349865Floor Panel · wornDURING M-CHECK FOUND MAIN CABIN FLOOR PANEL NR 61 WORN THROUGH AT 3 EA SCREW HOLES. REPAIRED PER SRM 53-01 FIGURE 4, SRM 53-23-0 FIGURE 4, SRM 51-30-2.SDR WX0A070646Floor Panel · delaminatedCABIN FLOORBOARD DELAMINATED AND PUNCTURED IN MULTIPLE AREAS, STS 1174 TO STA 1270, RBL 21 TO LBL 21, (FLOOR PANEL C-2). FABRICATED NEW CABIN FLOORBOARD IAW MD80 SRM 53-24-0 AND 53-05.SDR WX0A070645Floor Panel · puncturedFWD CABIN FLOORBOARD 'N' PUNCTURED IN MULTIPLE PLACES STA 160 TO STA 256, LBL 15 TO RBL 21. FABRICATED NEW FLOOR PANEL 'N' IAW MD80 SRM 53-24-0 AND 53-05.SDR WX0A070644Floorboard · puncturedFWD CABIN FLOORBOARD PUNCTURED IN SEVERAL AREAS STA 149 TO STA 160 RBL 32 TO RBL 55. FABRICATED NEW FLOOR PANEL IAW MD80 SRM 53-24-0 AND 53-05.SDR IPXA10163437Floor Panel · brokenINSPECTION TYPE:5 YR, FLOOR PANEL 242KF IS BROKEN AS MARKED. FABRICATED MAIN CARGO DECK FLOOR PANEL 242KF REF EO A300-5320- 16407-E APPX A AND B.SDR IPXA10163408Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD 242YK HAS 3 EA CRACKS. REPAIRED FLOORBOARD IAW SRM 53-10-20 8B FIG 203, EO A300-5320-38221-B, SRM 53-10-20 PARA 8A, FIG 201 & 202, AND EO A300-5320-38334-A.SDR IPXA10163406Floor Panel · crackedINSPECTION TYPE:5YR, MDC FLOOR PANEL 241UK CRACKED UNDER SURFACE. REPAIRED FLOOR PANEL IAW EO A300-5320-3221-B AND SRM 53-10-20 PARA 8B, FIG 203.SDR IPXA10163405Floor Panel · crackedINSPECTION TYPE:5YR, MCD FLOOR PANEL 242TK IS CRACKED AT LOWER SURFACE AS MARKED. REPAIRED MCD FLOOR PANEL IAW 53-10-20, PARA 8B, FIG 203 AND EO A300-5320-38221-B.SDR IPXA10163404Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 242VM IS CRACKED UNDER SURFACE REPAIRED FLOORBOARD IAW SRM 53-10-20, PARA 8B, FIG 203 AND EO A300-5320-38221-B.SDR IPXA10163401Floorboard · crackedINSPECTION TYPE:5 YR, MAIN CABIN FLOORBOARD 241BQ HAS A CRACK. REPAIRED FLOORBOARD IAW SRM 53-10-20 PARA 8B, FIG. 203 AND EO A300-5320-38221-B.SDR IPXA10163394Floor Panel · brokenINSPECTION TYPE:5 YR, MDC FLOOR PANEL 241YR BROKEN. FABRICATED FLOOR PANEL IAW EO A300-5320-16407-E.SDR DALA1028019865Floor Panel · damagedDURING M-CHECK FOUND PULLED OUT FASTENER HOLES AT MAIN CABIN FLOOR PANEL 81. REPAIRED PER SRM 53-05 FIGURE 1.SDR DALA1027963241Strap · corrodedDURING L CHECK FOUND CORROSION ON FLOORBOARD STRAP AT BETWEEN Y254 & Y254 FR 20. REPAIRED PER SRM 51-42-11, SRM 53-11-27 FIGURE 16, SRM 51-21-10 & SRM 51-75-12.SDR WX0A070647Floorboard · delaminatedFWD CABIN FLOORBOARD ''P' DELAMINATED STA 160 TO STA 256 RBL 23 TO RBL 44. FABRICATED NEW FLOOR PANEL 'P' IAW MD80 SRM 53-24-0 AND 53-05.SDR IPXA10163413Floor Panel · crackedINSPECTION TYPE:5YR, MCD FLOOR PANEL 251CN IS CRACKED AT LOWER SURFACE AS MARKED. REPAIRED DAMAGE IAW SRM 53-10-20 PARA 8B, FIG 203 AND EO A300- 5320-38221-B.SDR IPXA10163411Floor Panel · crackedINSPECTION TYPE:5YR, MDC FLOOR PANEL 252YR UNDER SURFACE CRACKED. REPAIRED FLOOR PANEL IAW SRM 53-10-20 PARA 8B, FIG. 203, AND EO A300-5320-3822-B.SDR IPXA10163410Floor Panel · crackedINSPECTION TYPE:5YR, MCD FLOOR PANEL 251PG IS CRACKED ON SEVERAL AREAS. REPAIRED FLOOR PANEL IAW SRM 53-10-20 PARA 8B, FIG 203 AND EO A300-5320-38221-B.SDR IPXA10163402Floor Panel · crackedINSPECTION TYPE:5 YR, MDC FLOOR PANEL 252XJ UNDER SURFACE CRACKED. REPAIRED FLOOR PANEL SRM 53-10-20 PARA 8B, FIG 203 AND EO A300-5320-38221-B.SDR IPXA10163397Floor Panel · brokenINSPECTION TYPE:5 YR, MCD FLOOR PANEL 251FJ IS BROKEN AT EDGE AS MARKED. FABRICATED NEW FLOOR PANEL IAW A300-5320-16407-E.SDR IPXA10163396Floor Panel · crackedINSPECTION TYPE:5 YR, MCD FLOOR PANEL 251YM IS CRACKED AT MULTIPLE AREAS LOWER SURFACE AS MARKED. FABRICATED FLOOR PANEL IAW A300-5320-16407-E.SDR IPXA10163392Floor Panel · brokenINSPECTION TYPE:5YR, MDC FLOOR PANEL 252UG BROKEN. FABRICATED FLOOR PANEL IAW EO A300-5320-16407-E.SDR IPXA10163356Floor Panel · peelingINSPECTION TYPE:5 YR, MCD FLOOR PANEL 251MG IS PEELED AT LOWER SURFACE AS MARKED. REPAIRED FLOOR PANEL IAW SRM 53-10-20 PARA 8B, FIG 203 AND EO A300-5320-38221-B.
Back to JASC 5321