What was found
INSPECTION TYPE:5YR, MDC FLOOR PANEL 252YR UNDER SURFACE CRACKED. REPAIRED FLOOR PANEL IAW SRM 53-10-20 PARA 8B, FIG. 203, AND EO A300-5320-3822-B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:5YR, MDC FLOOR PANEL 252YR UNDER SURFACE CRACKED. REPAIRED FLOOR PANEL IAW SRM 53-10-20 PARA 8B, FIG. 203, AND EO A300-5320-3822-B.