JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2010102592367Floor Panel · delaminatedBFM - S2 - MAJOR REPAIR - DELAMINATION ON FLOOR PANEL NR 261VF BETWEEN FR57.1 TO FR58, -Y450. REPLACED FLOOR PANEL NR 261VF BETWEEN FR57.1 TO FR58, -Y450 IAW SRM 53-02-00.SDR USAA2010101392279Floor Panel · corrodedBFM - S2 - MAJOR REPAIR - 2 HEATED FLOOR PANELS CORRODED AT R2 DOOR BETWEEN FR33 TO FR35A & BETWEEN -Y2462 TO -Y1456. REPLACED 2 HEATED FLOOR PANELS AT R2 DOOR BETWEEN FR33 TO FR35A & BETWEEN -Y2462 TO -Y1456 IAW TYPICAL REPAIR 53-02-01.SDR USAA2010101392274Floor Panel · corrodedBFM - S2 - MAJOR REPAIR - CORROSION ON HEATED FLOOR PANEL AT R1 DOOR AT FR14A, -Y1959. REPLACED HEATED FLOOR PANEL AT R1 DOOR AT FR14A, -Y1959 IAW TYPICAL REPAIR 53-02-01.SDR FDEA201010124021Floor Panel · delaminatedAIR CONDITIONING COMPARTMENT FLOOR PANEL 143 DF HAS A LARGE CORNER THAT IS DELAMINATED AND CONTAMINATED. FABRICATED NEW AIR CONDITIONING COMPARTMENT FLOOR PANEL 143 DF IAW DWG SRZ 25-005, REV "H".SDR USAA2010102592368Floor Panel · delaminatedBFM - S2 - MAJOR REPAIR - NR 6298258 - DELAMINATION ON FLOOR PANEL NR 251ZF BETWEEN FR40.1 TO FR43 & BETWEEN Y1456 TO Y1959. REPLACED FLOOR PANEL NR 251ZF BETWEEN FR40.1 TO FR43 & BETWEEN Y1456 TO Y1959 IAW SRM 53-02-00.SDR IPXA10663056Floorboard · damagedHOLE IN MCD FLOORBOARD POSITION 4 CTR FS.635, LBL3. REPAIRED IAW SRM 53-00-50-2R PARA 6.SDR CALA2010101100478Floor Panel · puncturedSUPPORT TASK - CABIN FLOOR PANEL 242AF HAS NUMBEROUS PUNCTURED HOLE. FABRICATED FLOOR PANEL 242AF PER EC/RA 5320-01448.SDR USAA2010101292267Floor Panel · corrodedBFM - S2 - MAJOR REPAIR - MAIN CABIN FLOOR PANEL 272KF HAS CORROSION BETWEEN FR72 TO FR76, S25R. REPLACED MAIN CABIN HEATED FLOOR PANEL 272KF BETWEEN FR72 TO FR76, S25R IAW A330 SRM 51-21-00 & TYPICAL REPAIR 53-02-01.SDR IPXA10563029Floor Panel · damagedMAIN CARGO DECK FLOOR PANEL ZONE 131 OTBD HAS DAMAGE TO EDGE. MFG AND INSTALLED NEW FLOOR PANEL IAW EO B757-5320-9692-G AND AMM-53-01-01.SDR IPXA10563028Floor Panel · damagedMAIN CARGO DECK ZONE 131 INBD FLOOR PANEL HAS DAMAGE TO EDGE, CRUSHED. MFG AND REPLACED FLOOR PANEL IAW EOB757-5320-9692-G AND AMM-53-01-01.SDR IPXA10563320Floor Panel · corrodedINSPECTION TYPE:C4, ACB NR 2 FLOOR PANEL IS CORRODED. REPLACED FLOOR PANEL IAW SRM 51-40-05-0G & SRM 51-40-08-0G.SDR IPXA10563314Floor Panel · corrodedINSPECTION TYPE:C4, ACB NR 4 FLOOR PANEL IS CORRODED. REPLACED FLOOR PANEL IAW SRM 51-40-05-0G AND SRM 51-20-01-0G.SDR IPXA10563313Floor Panel · corrodedINSPECTION TYPE:C4, ACB NR3 FLOOR PANEL IS CORRODED. REPLACED FLOOR PANEL IAW SRM 51-40-05-0G AND SRM 51-20-01-0G.SDR IPXA10563286Floorboard · brokenINSPECTION TYPE:C4, MCB FLOOR PNL BS 1020-1060 LBL 25-45 HAS EDGE DAMAGE AND CORNERS ARE BROKEN. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563254Floor Panel · brokenINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1100-1200 LBL 45-65 WL 208 HAS BROKEN AND MISSING INSERTS. FABRCATED REPLACEMENT FLOOR PANEL PER UPS E.O. B757-5320-9692-GSDR IPXA10563246Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1100-1200, LBL 25-45, WL 208 HAS 3 AREAS OF EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563245Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1020-1060 LBL 45-65 WL 208 CORNER IS DAMAGED AND LOWER SURFACE IS PUNCTURED. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10563159Floorboard · puncturedINSPECTION TYPE:C4, MCB FLOOR PNL BS 1100-1200 BL 0-RBL25 UPR SURFACE PUNCTURED, 1 MISSING 1 BROKEN INSERT. FABRICATED FLOOR PANEL REPLACEMENT IAW EO B757-5320-9692-G.SDR F3LA2010072700522Floor Panel · delaminatedC-CHECK: NON ROUTINE N0434; AT CARGO PIT PANEL 151HE UPPER SURFACE IS DELEMINATED. FABRICATED FLOOR PANEL IAW MC GILL IRM 9701 REVISION G, PARA 3.2 TABLE 1.SDR IPXA10563101Floor Panel · brokenINSPECTION TYPE:C4 MAIN CARGO BAY FLOOR PANEL BS 900-1020, LBL 45 - 65, WL 208 HAS EDGE DAMAGE AND BROKEN END OF PANEL. FABRICATED REPLACEMENT PANEL IAW ER B757-5320-9692-G.SDR IPXA10563055Floor Panel · damagedINSPECTION TYPE:C4, MCB FLOOR PANEL, BS 900-1020 LBL 25-45 HAS EDGE DAMAGE AT CORNER. REPLACED FLOORBOARD IAW EO B757-5320-9692-G AND EO B757-5100-33281-B.SDR DALA1025889886Floor Panel · corrodedDURING M-CHECK FOUND CORROSION ON MAIN CABIN FLOOR PANEL NR16. REPAIRED IAW SRM 51-10-04, SRM 51-60-0 & SRM 51-30-01 PAGE 239.SDR DALA1025879886Floor Panel · damagedDURING M-CHECK FOUND EXCESSIVE FLEX IN MAIN CABIN FLOOR PANEL NR60D. REPLACED FLOOR PANEL IAW SRM 51-30-1, PAGE 177.SDR DALA1025819865Floorboard · puncturedDURING M-CHECK FOUND SKIN PUNCTURED IN MAIN CABIN FLOORBOARD NR 99. REPAIRED IAW SRM 53-05 FIG 1.SDR A6WA201040847Floorboard · corrodedLBL 27 HAS CORROSION AROUND 7 SCREW HOLES. LOCATED UNDER FLOORBOARD 281LLF. R & R FLOORBEAM CAP AT LBL 27.0 BETWEEN FS 569-610 IAW REO 601R-53-61-3778.SDR IPXA10163578Floor Panel · gougedINSPECTION TYPE:10YR, AFT CARGO FLOOR PANEL 152UF IS GOUGED AND DELAMINATED. FABRICATED NEW NEW AFT CARGO FLOOR PANEL 152UF IAW EO A300-5320-16407-E, APPENDIX A/C.SDR IPXA10163219Floorboard · dentedINSPECTION TYPE:10YR, NUMEROUS DENTS ON BULK CARGO FLOORBOARD NR 161LF. FABRICATED BULK CARGO FLOORBOARD NR 161LF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA10163217Floorboard · puncturedINSPECTION TYPE:10YR, NUMEROUS PUNCTURES AND DENTS ON BULK CARGO FLOORBOARD NR 161JF. FABRICATED BULK CARGO FLOORBOARD NR 161JF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA10163216Floorboard · damagedINSPECTION TYPE:10YR, EDGE DAMAGE ON AFT CARGO FLOORBOARD NR 152SF. ACCOMPLISHED REPAIR ON AFT CARGO FLOORBOARD NR 152SF IAW EO A300-5320-38221-B, PARA 6A.SDR IPXA10163215Floorboard · crackedINSPECTION TYPE:10YR, CRACKED BOTTOM ON AFT CARGO FLOORBOARD NR 151SF. ACCOMPLISHED REPAIR ON AFT CARGO FLOORBOARD NR 151SF IAW EO A300-5320-38221-B PARA 6A.SDR IPXA10163214Floorboard · puncturedINSPECTION TYPE:10YR, NUMEROUS DENTS, HOLES AND PUNCTURES ON BULK CARGO FLOORBOARD NR161GF. FABRICATED BULK CARGO FLOORBOARD NR161GF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA10163213Floorboard · dentedINSPECTION TYPE:10YR, NUMEROUS DENTS ON BULK CARGO FLOORBOARD NR 161MF. FABRICATED BULK CARGO FLOORBOARD NR161MF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA10163212Floorboard · damagedINSPECTION TYPE:10YR, NUMEROUS DENTS, HOLES ON BULK CARGO FLOORBOARD NR 161HF. FABRICATED BULK CARGO FLOORBOARD NR 161HF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA10163211Floorboard · dentedINSPECTION TYPE:10YR, EXISTING REPAIR LOOSE, DENTS ON BULK CARGO FLOORBOARD NR 162HF. FABRICATED BULK CARGO FLOORBOARD NR 162HF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA10163138Floor Panel · crackedINSPECTION TYPE:10YR, FWD CARGO COMPT FLOOR PANEL 131MG IS CRACKED. FWD CARGO COMPT FLOOR PANEL 131MG IAW EO A300-5320-38221-B, PARA 6A.SDR IPXA10163137Floor Panel · crackedINSPECTION TYPE:10YR, FWD CARGO FLOOR PANEL 131SG IS CRACKED. REPAIRED FWD CARGO FLOOR PANEL 131SG IAW EO A300-5320-38221-B, PARA 6A.SDR IPXA10163136Floor Panel · crackedINSPECTION TYPE:10YR, AFT CARGO FLOOR PANEL 152TF IS CRACKED. REPAIRED AFT CARGO FLOOR PANEL 152TF IAW EO A300-5320-38221-B, PARA 6A.SDR IPXA10163135Floor Panel · crackedINSPECTION TYPE:10YR, CRACKED BOTTOM OF AFT CARGO FLOOR PANEL 151NG. REPAIRED AFT CARGO FLOOR PANEL 151NG IAW EO A300-5320-38221-B, PARA 6A.SDR IPXA10163134Floor Panel · crackedINSPECTION TYPE:10YR, CRACKED BOTTOM ON AFT CARGO FLOOR PANEL 152QF. REPAIRED AFT CARGO FLOOR PANEL 152QF IAW EO A300-5320-38221-B, PARA 6A.SDR IPXA10163133Floor Panel · crackedINSPECTION TYPE:10YR, CRACKED BOTTOM AND DELAMINATED AFT CARGO FLOOR PANEL 151QF. REPAIRED AFT CARGO FLOOR PANEL 151QF IAW EO A300-5320-38221-B, PARA 6A.SDR IPXA10163057Floorboard · puncturedINSPECTION TYPE:10YR, AFT CARGO FLOORBOARD 151LG HAS A PUNCTURE. FABRICATED AFT CARGO FLOORBOARD NR151LG IAW EO A300-5320-16407-E, APPENDIX C.SDR IPXA10563492Floor Skin · corrodedINSP TYPE:C4, CORROSION ON FLOOR, AROUND BASE OF FO'S INBD FWD SEAT TRACK BS 240 TO 257. REPAIRED CORROSION DAMAGE IAW EO B757-5310-40356-A AND ER 10-05121.SDR IPXA10563474Floor Skin · corrodedINSPECTION TYPE:C4 CORROSION ON FLOOR, BS 253.5, RBL 6 REPAIRED IAW ATS ER 10-05226 DATED 10-30-10.SDR IPXA10563453Floor Skin · corrodedINSPECTION TYPE:C4, CORROSION ON FLOOR BS 274, RBL 13. REPAIRED IAW ER 10-05121.SDR IPXA10563452Floor Skin · corrodedINSPECTION TYPE:C4, CORROSION ON FLOOR AROUND BASE OF F/O'S AFT OTBD SEAT TRACK BS 254-271, RBL 26-35. REPAIRED IAW ER NR10-05121.SDR IPXA10563423Floorboard · puncturedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1681-1720, BL 0-RBL 60 IS PUNCTURED, DAMAGED BEYOND SRM LIMITS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563388Floor Support · corrodedINSPECTION TYPE:C4, FUSE UPPER LOBE, CORROSION ON FLOOR SUPPORT, BS 297-310, LBL 59, WL 208. R & R FLOOR SUPPORT IAW SRM 51-10-02-0G, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01-0G.SDR IPXA10563371Floorboard · delaminatedINSPECTION TYPE:C4, BS 1020 TO 1060 BL 0 TO LBL 25 FLOORBOARD IS DELAMINATED AT EDGES. FABRICATED REPLACEMENT FLOORBOARD IAW B757-5320-9692-G.SDR IPXA10563323Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1600-1681, RBL 45-60 HAS DAMAGED INSERTS DELAMINATED (DAMAGE BEYOND SRM LIMITS ). FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563322Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS1600-1681, LBL45-60 HAS DAMAGED INSERT (DAMAGE BEYOND SRM LIMITS). FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.
Back to JASC 5321