SDR IPXA10563289Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1600-1681, BL 0-RBL 25 HAS DAMAGED INSERTS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563278Floorboard · delaminatedINSPECTION TYPE:C4, BS 1020 TO 1040, BL 0 TO RBL 25 FLOORBOARD IS DELAMINATED AT EDGES AND HAS DAMAGED INSERTS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563267Floorboard · delaminatedINSPECTION TYPE:C4, BS 1200-1100, RBL 45-65, WL 208 FLOORBOARD IS DELAMINATED AT EDGES AND HAS DAMAGED INSERTS (DAMAGE BEYOND SRM LIMITS). FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10563266Floorboard · delaminatedINSPECTION TYPE:C4, BS 1100-1060, LBL 45-65, WL 208 FLOORBOARD IS DELAMINATED AT EDGES (DAMAGE BEYOND SRM LIMITS). FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563265Floorboard · crackedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1681-1720, BL 0-LBL 60 HAS MISSING INSERTS AND IS CRACKED. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563256Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD, BS 1540-1600, BL 0-RBL 25 DELAMINATED. FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A1, EO B757-5320-9692-G AND SRM B757-5100-33281-B.SDR IPXA10563255Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CABIN FLOOR BOARD BS 1200-1320 LBL 45-60 HAS MISSING INSERTS, PUNCTURES. FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A1 EO B757-5320-9692-G AND SRM B757-5100-33281-B.SDR IPXA10563243Floor Panel · delaminatedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1060 -1100, RBL 25 - 45, WL 208 IS PUNCTURED AND DELAMINATED AT EDGES. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA10563242Floor Panel · delaminatedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1060 - 1100, RBL 45 - 65, WL 208 IS DELAMINATED AT EDGES. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563238Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 340- 440 BL0 - RBL 25, WL 208 HAS 1 DAMAGED INSERT. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563206Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560 - 620, LBL 45 - 62, WL 208 IS WORN THROUGH THE REINFORCING FIBREGLASS PLIES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692 AND SRM 53-00-50-2R1.SDR IPXA10563205Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 879 - 900 BL - RBL 25, WL 208 HAS ONE DAMAGED INSERT AND 7 DISBONDED INSERTS. FABRICATED NEW MAIN CARGO BAY FLOOR PANEL IAW EO B757-5320-9692-G AND EO B757-5100-33281 B.SDR IPXA10563189Floor Panel · crackedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420- 1400, RBL 25-45 HAS MISSING INSERT. REPLACED IAW EO B757-5320-9692-G.SDR IPXA10563188Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420-1540, RBL 45-60, HAS MISSING INSERT. REPLACED FLOORBOARD IAW B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10563166Floorboard · puncturedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420-1540, RBL 25-RBL 45, HAS MISSING INSERTS, PUNCTURED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G; EO B757-5100- 33281-B; SRM 53-00-50-1A1.SDR IPXA10563165Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420-1540, LBL 25-LBL 45 HAS MISSING INSERTS. REPLACED FLOORBOARD IAW EO B757-5320-9692-G; EO B757-5100- 33281-B; SRM 53-00-50-1A1.SDR IPXA10563164Floorboard · brokenINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1420-1540, LBL 45-LBL 60 IS BROKEN FABRICATED FLOORBOARD REPLACEMENT IAW EO B757-5100-33281 B.SDR IPXA10563163Floorboard · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOORBOARD BS 480-560, LBL 45-62, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES. FABRICATED FLOORBOARD REPLACEMENT IAW EO B757-5320-9692-G.SDR IPXA10563160Floorboard · delaminatedINSPECTION TYPE:C4, BS 1200 TO 1100, LBL 25-BL 0 FLOORBOARD IS DELAMINATED AT EDGES AND HAS DAMAGED INSERTS. FABRICATED FLOORBOARD REPLACEMENT IAW EO B757-5320-9692-G.SDR IPXA10563156Floor Panel · puncturedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1320-1400, RBL 25-45, WL 208 IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563151Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 879-900, RBL 45-62, WL 208 HAS 2 DAMAGED INSERTS. FABRICATED REPLACEMENT FLOOR PANEL IAW E0 B757-5320-9692-G.SDR IPXA10563150Floor Panel · delaminatedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 1020-1060, RBL 45-65, WL 208 IS DELAMINATED AT EDGES. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10563149Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560-620, BL 0 - RBL 25, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563148Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 480-560, RBL 45-62, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT PANEL IAW ER B757-5320-9692-G.SDR IPXA10563147Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560-620, RBL 25-45, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563146Floorboard · brokenINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1320-1420 RBL 45-RBL 60 IS BROKEN. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563126Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 480 - 560, RBL 25 - 45, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563125Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 480 - 560, BL 0 - RBL 25, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563124Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560 - 620, LBL 25 - 45, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563123Floor Panel · wornINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 560- 620, BL0 - LBL 25, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563121Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1320-1420, LBL 25- 45 HAS MISSING INSERT. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10563105Floorboard · puncturedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1200 -1320, RBL 45 - RBL 60 IS HAS MISSING INSERTS, PUNCTURED. FABRICATED REPLACEMENT FOR MAIN CABIN FLOORBOARD BS 1200 - 1320 RBL 45 -RBL 60 IAW EO B757-5320-9692-G.SDR IPXA10563104Floorboard · puncturedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1200-1320, RBL 25-RBL 45 IS PUNCTURED. FABRICATED REPLACEMENT FOR MAIN CABIN FLOORBOARD BS 1200-1320, RBL 25 - RBL 45 IAW EO B757-5320-9692-G.SDR IPXA10563103Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1200-1320 BL 0 - LBL 25 IS DELAMINATED. FABRICATED REPLACEMENT FOR MAIN CABIN FLOORBOARD BS 1200-1320, BL0 - LBL 25 IAW EO B757-5320-9692-G.SDR IPXA10563100Floorboard · puncturedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1320-1420, LBL 45 - LBL 60 IS PUNCTURED. FABRICATED REPLACEMENT FLOORBOARD AT MAIN CABIN BS 1320 -1420, LBL 45 - LBL 60 IAW EO NR B757-5320-9692-G.SDR IPXA10563090Floor Panel · wornINSPECTION TYPE:C4, MCB FLOOR PANEL BS 480-560, BL0 - LBL 25, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES. REPLACED MCB FLOOR PNL IAW EO NO B757-5320-9692-G, STEPS 1-7.SDR IPXA10563077Floor Panel · puncturedINSPECTION TYPE:C4, MAIN CARGO BAY FLOOR PANEL BS 480-560, LBL 25-45, WL 208 IS WORN THROUGH THE REINFORCING FIBERGLASS PLIES AND IS PUNCTURED. FABRICATED REPLACEMENT FLOOR PANEL IAW ER B757-5320-9692-G.SDR IPXA10563062Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGE BAY FLOOR PANEL BS 820-879 LBL 45-60 WL 208 IS DAMAGED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO NO B757-5320-9692-G.SDR IPXA10163132Floor Panel · gougedINSPECTION TYPE:10YR, MAIN CARGO DECK FLOOR PANEL 231RG IS GOUGED AT 2 PLACES. REPAIRED MAIN CARGO DECK FLOOR PANEL 231RG IAW EO A300-5320-38221-B.SDR IPXA10163128Floor Panel · brokenINSPECTION TYPE:10YR, MAIN CARGO DECK FLOOR PANEL 231MJ IS BROKEN. FABRICATED NEW MAIN CARGO DECK FLOOR PANEL 231MJ IAW EO A300-5320-16407-E, APPENDIX A/B.SDR IPXA10163069Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 231HG IS CRACKED. REPAIRED MAIN CABIN FLOORBOARD NR 231HG IAW EO A300-5320-38221-B PARA 6A.SDR IPXA10163068Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 232YG IS CRACKED AT EDGE. REPAIRED MAIN CABIN FLOORBOARD NR 232YG IAW EO A300-5320-38221-B PARA 6A.SDR IPXA10163067Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 231TG IS CRACKED. REPAIRED MAIN CABIN FLOORBOARD NR 231TG IAWEO A300-5320-38221-B PARA. 6A.SDR IPXA10163066Floorboard · crackedINSPECTION TYPE:10YR, MAIN CARGO COMPARTMENT FLOORBOARD NR 241SK HAS A CRACK. REPAIRED MAIN CABIN FLOORBOARD NR 241SK IAW EO A300-5320-38221-B PARA. 6A.SDR IPXA10163065Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 231LH IS CRACKED. REPAIRED MAIN CABIN FLOORBOARD NR 231LH IAW EO A300-5320-38221-B PARA. 6A.SDR IPXA10163064Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 232NJ IS CRACKED AT EDGE. REPAIRED MAIN CABIN FLOORBOARD NR 232NJ IAW EO A300-5320-38221-B PARA. 6A.SDR IPXA10163061Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 231VG IS CRACKED. REPAIRED MAIN CABIN FLOORBOARD NR 231VG IAW EO A300-5320-38221-B PARA 6A.SDR IPXA10563054Floorboard · delaminatedINSPECTION TYPE:C4, BS 1200 TO 1100, RBL 25 TO 45 FLOORBOARD IS DELAMINATED AT EDGES AND HAS DAMAGED INSERTS. REPLACED FLOORBOARD IAW EO B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10563048Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1600-1681, LBL 25-LBL 45 HAS DAMAGED INSERTS. REPLACED FLOORBOARD IAW EO B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10563047Floorboard · damagedINSPECTION TYPE:C4, MAIN CABIN FLOORBOARD BS 1600-1681 RBL 25-RBL 45 HAS DAMAGED INSERTS, PUNCTURED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G AND EO B757-5100-33281-B.
Back to JASC 5321