SDR IPXA10662541Floor Panel · damagedINSPECTION TYPE:C, MCD STA 830 TO 933 LBL 11" TO RBL 11" FLOOR PANEL FOUND 1 DAMAGED & 9 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662540Floor Panel · damagedINSPECTION TYPE:C, MCD STA 984 TO 1087 LBL 77" TO LBL 89" FLOOR PANEL FOUND 1 DAMAGED & 8 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10662539Floor Panel · damagedINSPECTION TYPE:C, MCD STA 977 TO 1114 LBL 11" TO RBL 11" FLOOR PANEL FOUND 1 DAMAGE AND 11 DENT MARKS. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-01.SDR IPXA10562495Floor Panel · crackedINSPECTION TYPE:C3, MAIN CARGO BAY FLOOR PANEL BS 480-560 RBL 45-60 IS CRACKING. FABRICATED NEW FLOOR PANEL IAW UPS EO B757-5320-9692-G.SDR IPXA10562467Floor Panel · corrodedINSPECTION TYPE:C3, FWD CARGO NR 4 FLOOR PANEL UPPER SURFACE HAS AREAS OF CORROSION. FABRICATED FWD CARGO NR 4 FLOOR PANEL IAW SRM 51-40-05-0G.SDR IPXA10562643Floorboard · damagedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD BS 1600-1680, LBL 45 TO LBL 65, MISSING INSERT AND MULTIPLE PUNCTURES. FABRICATED REPLACEMENT FLOOR BOARD IAW EO NR B757-5320-9692-G.SDR IPXA10562628Floorboard · damagedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD STA 1540-1600, BL0, RBL25, 4 DAMAGED INSERTS. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10562624Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL STA 900-1020 RBL 45-60 HAS MISSING INSERTS AT STA 1020. R & R FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562622Floorboard · puncturedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD STA 1580-1600 RBL 45 TO RBL 65 DEBONDED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562602Floor Panel · damagedINSPECTION TYPE:C3, FOUND FLOORBOARD STA 900-1020, LBL 45-65 LT HAS DAMAGED INSERT FWD OTBD EDGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G, EO NR B757-5100-33281-B.SDR IPXA10562600Floor Panel · puncturedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD PANEL BS 1200-1320, BL 0 TO LBL 25, 2 PUNCTURES IN THE UNDERSIDE. REPLACED FLOOR PANEL IAW EO NR B757-5320-9692-G AND EO NR B757-5100-33281-B.SDR IPXA10562592Floor Panel · puncturedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD BS 1320-1420, BL0-LBL 25, 2 PUNCTURES IN THE UNDERSIDE. REPLACED IAW EO B757-5320-9692-G, B757-5100-33281-B.SDR IPXA10562590Floor Panel · puncturedINSPECTION TYPE:C3, FOUND FLOOR PANEL STA 900-1020 RBL 25-45 HAS PUNCTURE DAMAGE UNDERSIDE OTBD AT STA 1000. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562588Floor Panel · puncturedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD STA 1420-1540, LBL 25-45, 2 PUNCTURES ON THE UNDERSIDE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562561Floor Panel · debondedINSPECTION TYPE:C3, MAIN CARGO FLOOR PANEL BS 1200-1320, BL0 TO RBL 25 DISBONDED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562560Floor Panel · debondedINSPECTION TYPE:C3, FOUND FLOOR PANEL STA 1100-1180 BL 0-25 LT HAS DAMAGED INSERT AT STA 1180 AFT INBD CORNER. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562555Floorboard · damagedINSPECTION TYPE:C3, FOUND FLOORBOARD STA 900-1020, LBL 0-25 LT HAS DAMAGED CORE INBD MID. REPLACED IAW UPS EO B757-5320-9692-G AND EO B757-5100-33281-B.SDR IPXA10562554Floorboard · puncturedINSPECTION TYPE:C3, FOUND FLOORBOARD STA 900-1015, LBL 25-45 LT HAS PUNCTURES FWD UNDERSIDE. REPLACED IAW EO B757-5320-9692-G AND EO B757-5100- 33281-B.SDR IPXA10562521Floor Panel · puncturedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD BS 1420-1540, BL 0 TO LBL 25, NUMEROUS PUNCTURES ON THE UNDERSIDE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G, EO B757-5100-33281-B AND SRM 53-00-50-1A.SDR IPXA10562520Floor Panel · debondedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD BS 1600-1680, LBL 25 TO LBL 45, DISBONDED AND MULTIPLE PUNCTURES. R & R FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562519Floorboard · debondedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD BS 1600-1680, BL 0 TO LBL 25, DEBONDED. R & R FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10562512Floorboard · debondedINSPECTION TYPE:C3, MAIN CARGO FLOORBOARD BS 1320-1420, LBL 25-45, IS DEBONDED. REPLACED IAW EO NR757-5320-9692-G, EO B757-5100-33281-B.SDR IPXA10562449Floor Panel · damagedFLOOR PANEL PN 143N5457-95 IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692 ON NR 355057.SDR IPXA10562448Floor Panel · damagedFLOOR PANEL IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692 ON NRC 355056.SDR IPXA10562447Floor Panel · damagedFLOOR PANEL DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692 ON NRC 355074.SDR DALA1021409868Floor Panel · damagedDURING M-CHECK, FOUND SKIN DAMAGED ON FLOOR PANEL NR 73. REPAIRED IAW SRM 53-23-2, SRM 51-30-2 & SRM 51-20-1.SDR DALA1021399868Floor Panel · crackedDURING M-CHECK FOUND TOP SKIN FASTENER HEADS PULLED AND SKIN CRACKED IN FLOOR PANEL NR70. REPAIRED IAW SRM 51-70-4, SRM 51-30-2.SDR IPXA10562367Floorboard · puncturedINSPECTION TYPE:C3, MAIN CARGO DECK FLOORBOARD BS 620-720, LBL 25-45 EDGES PUNCTURED AND DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G; B757-5100-33281-B.SDR IPXA10562363Floor Panel · damagedFLOOR PANEL DAMAGED. REPAIRED IAW EO B757-5320-9692-G.SDR IPXA10162612Floorboard · damagedINSPECTION TYPE:5YRF, REPAIR VALIDATION SURVEY, REPAIR OF BULK PIT FLOORBOARD NR161JF HAS DAMAGE. FABRICATED BULK CARGO FLOORBOARD NR161JF IAW EO, APPENDIX D.SDR IPXA10162610Floorboard · misrepairedINSPECTION TYPE:5YRF, REPAIR VALIDATION SURVEY, REPAIR OF BULK CARGO FLOORBOARD NR161HF. FABRICATED BULK CARGO FLOORBOARD NR161HF IAW EO APPENDIX D.SDR IPXA10162609Floorboard · misrepairedINSPECTION TYPE:5YR, REPAIR VALIDATION SURVEY,REPAIR OF BULK CARGO FLOOR PANEL NR161GF. FABRICATED BULK CARGO FLOORBOARD NR161GF IAW EO A300-5320-16407-E, APPENDIX D.SDR DALA1021193274Floor Panel · damagedDURING LINE CHECK FOUND FWD CARGO FLOOR PANEL 131EF WITH SEVERAL SCREWS PULLED THROUGH. REPLACED FLOOR PANEL IAW SRM 53-22-14, PAGE 401.SDR DALA1021183274Floor Panel · damagedDURING LINE CHECK FOUND FWD CARGO FLOOR PANEL 131AF WITH SEVERAL SCREWS PULLED THROUGH. REPLACED FLOOR PANEL IAW SRM 53-22-14 PAGE 401.SDR IPXA10562907Floor Skin · corrodedINSPECTION TYPE:C3, COCKPIT FLOOR HAS CORROSION BS 278, LBL 4, WL 201. REPAIR IAW ER 10-4471.SDR IPXA10562906Floor Skin · corrodedINSPECTION TYPE:C3, COCKPIT FLOOR HAS DAMAGE AT BS 256, LBL 42, WL 201. REPAIR IAW ER 10-4471.SDR IPXA10562905Floor Skin · corrodedINSPECTION TYPE:C3, COCKPIT FLOOR HAS CORROSION BS 281, LBL 20, WL 201. REPAIR IAW ER 10-4471.SDR IPXA10562358Floorboard · damagedDAMAGED FLOORBOARD POS .7500 LT RBL25.45. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692.SDR DALA1021163101Floor Panel · dentedDURING M-CHECK, FOUND DENTS ON FLOOR PANEL 151ZG. REPLACED FLOOR PANEL IAW DWG 3D25-40532.SDR IPXA10162640Floorboard · brokenINSPECTION TYPE:10YR, MAIN CABIN COMPARTMENT FLOORBOARD NR241MN HAS A BROKEN CORNER AT FWD INBD SIDE AND ONE DENT ON UPPER SKIN. FABRICATED MAIN CABIN FLOORBOARD NR241MN IAW EO A300-5320-16407-E, APPENDIX B.SDR IPXA10162423Floorboard · crackedINSPECTION TYPE:10YR, MAIN CABIN FLOORBOARD NR 241HN HAS A CRACK AT CORNER. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBOARD NR 241HN IAW EO A300-5320-38221-B PARA 6A.SDR ASOA201001266Pressure Panel · crackedFOUND FS 460 PRESSURE FLOOR HAS INDICATION NOTED BETWEEN BL 0 AND RBL 9.0 3.0" IN LENGTH 50 PERCENT FSH FAILED NDT INSP. AREA MARKED ON ACFT. C/W STEP 1 OF REO 601R-53-41-1276. C/W STEPS 2, 3, AND 5 OF REO 601R-53-41-1276. C/W STEP 4 OF REO 601R-53-41-1276. CSDR ASOA201001263Floor Panel · crackedFOUND FS 460 PRESSURE FLOOR HAS 2 INDICATIONS NOTED. 1 BETWEEN BL0.0 AND RBL 9.0 2.8" IN LENGTH, 50 PERCENT FSH AND 2ND BETWEEN BL0.0 AND LBL 9.0 2.8" IN LENGTH 50 PERCENT FSH. BOTH FAILED NDT INSP. C/W STEP 1 OF REO 601R-53-41-1279. PERFORMED EDDY CURRENT.SDR DALA1021033210Floorboard · damagedFOUND FWD CARGO FLOORBOARDS DAMAGED BEYOND SRM LIMITS. R & R CARGO FLOORBOARDS 131AE AND 131EG IAW AMM 53-22-14.SDR IPXA10562743Floorboard · brokenINSP TYPE:C3 MAIN CARGO DECK FLOORBOARD BS 720-820 LBL 45-65 FLOORBOARD IS BROKEN AT BS 760 TOP SIDE. FABRICATED REPLACEMENT FLOORBOARD IAW EO BO. B757-5320-9692-G.SDR IPXA10562717Floorboard · debondedINSPECTION TYPE:C3, SECTION 46, MAIN DECK FLOOR STRUCTURE, FLOORBOARD PANEL, AT BS 1681.8 - BS 1600, LBL 45- LBL 61, LWR AFT INBD SKIN IS DISBONDED AND BROKEN AWAY. FABRICATED REPLACEMENT FLOORBOARD IAW EO NO B757-5320-9692-G.SDR IPXA10562663Floorboard · damagedINSPECTION TYPE:C3, SECT 46, MAIN DECK FLOOR STRUCTURE, FLOORBOARD AT BS 1200-1320, LBL 25-45 HAS MISSING INSERTS AT BS 1220, AND BS 1250, LBL 44. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10162639Floorboard · delaminatedINSPECTION TYPE:10YR, MAIN CARGO COMPARTMENT ZONE 231, NR 231PJ. FLOORBOARD HAS DELAMINATED AREA AT UPPER SKIN. FABRICATED MAIN CABIN FLOORBOARD NR 231PJ IAW EO A300-5320-16407-E, APPENDIX B.SDR IPXA10562604Floorboard · damagedINSPECTION TYPE:C3, MAIN CARGO DECK FLOORBOARD AT BS 480-560 LBL 45-65 INSERT MISSING AND TOP OF FLOORBOARD IS WORN THROUGH. REPLACED IAW EO B757-5320-9692-G, SRM 53-00-50-2R1.SDR IPXA10562569Floorboard · wornINSPECTION TYPE:C3, MAIN CARGO DECK FLOORBOARD BS 540-620, LBL 45-65, TOP OF FLOORBOARD IS WORN. REPLACED FLOORBOARD BY FABRICATING NEW FLOORBOARD IAW EO B757-5320-9692-G, AND SRM 53-00-50-2R1.
Back to JASC 5321