What was found
FOUND FS 460 PRESSURE FLOOR HAS 2 INDICATIONS NOTED. 1 BETWEEN BL0.0 AND RBL 9.0 2.8" IN LENGTH, 50 PERCENT FSH AND 2ND BETWEEN BL0.0 AND LBL 9.0 2.8" IN LENGTH 50 PERCENT FSH. BOTH FAILED NDT INSP. C/W STEP 1 OF REO 601R-53-41-1279. PERFORMED EDDY CURRENT. C/W STEPS 2, 3, AND 15 OF REO 601R-53-41-1279. C/W STEPS 4 THRU 11 AND 16 & 17 OF REO 601R-53-41-1279. C/W STEPS 12, 13, 14 OF REO 601R-53-41-1279. INSTALLED 20 PLT 2145-9 FASTENERS COMMON TO FS 460 RBL 9 - LBL 9 IAW REO 601R-53-41-1279. REMOVED & REPLACED INTERCOSTAL (PN 601R81172-7) IAW SRM 51-42-21. C/W ASA ECTC REO 601R-53-41-1279. CONTINUED ON MWC 8719631 OP 631.