JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA09557674Floorboard · dentedINSPECTION TYPE:C2 MAIN CARGO COMPARTMENT FLOORBOARD IS DENTED AT BS 1419 RBL15. FLOOR BOARD WAS REPLACED PER EO 757-5320-9692-G.SDR IPXA09557607Floor Panel · corrodedINSPECTION TYPE:C-2 AFT CARGO COMPARTMENT NR 4 FLOOR PANEL HAS CORROSION UNDER THE MBA SYSTEM, AND MBA SYSTEM HOLD DOWN ARMS. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT AFT CARGO COMPARTMENT NR 4 FLOOR PANEL IAW SRM 53-60-53-01 & MM 25-50-04-4.SDR IPXA09557606Floor Panel · corrodedINSPECTION TYPE:C-2 AFT CARGO COMPARTMENT NR 2 FLOOR PANEL HAS CORROSION UNDER THE MBA SYSTEM, AND MBA SYSTEM HOLD DOWN ARMS. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT AFT CARGO COMPARTMENT NR 2 FLOOR PANEL IAW SRM 53-60-53-01 & MM 25-50-04-4.SDR IPXA09557605Floor Panel · corrodedINSPECTION TYPE:C-2 AFT CARGO COMPARTMENT NR 1 FLOOR PANEL HAS CORROSION UNDER THE MBA SYSTEM, AND MBA SYSTEM HOLD DOWN ARMS. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT AFT CARGO COMPARTMENT NR 1 FLOOR PANEL IAW SRM 53-60-53-01 & MM 25-50-04-4.SDR IPXA09557604Floor Panel · corrodedINSPECTION TYPE:C-2 AFT CARGO COMPARTMENT NR 3 FLOOR PANEL HAS CORROSION UNDER THE MBA SYSTEM BS 1330 TO BS 1470. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT AFT CARGO COMPARTMENT NR 3 FLOOR PANEL IAW SRM 53-60-53-01 & MM 25-50-04-4.SDR IPXA09557603Floor Panel · corrodedINSPECTION TYPE:C2 FWD CARGO BAY, NR 4 FLOOR PANEL HAS CORROSION UNDER THE MBA SYSTEM. REMOVED AND REPLACED FLOOR PANEL PER SRM 51-20-01-0G.SDR FDEA200910083512Floor Panel · crackedMAIN CABIN FLOOR PANEL 251 BH, CRACKED. FABRICATED NEW PANEL; LOCATED HOLES; BORED AND INSTALLED INSERTS; POTTED EDGES AND CURED; SANDED EDGES; APPLIED ANTI-SKID AND PART MARKED IAW DWG SRZ 25-005; REV "H".SDR ASOA200901111Floor Skin · crackedHFEC INDICATION NOTED AT 60% FSH APPROX 1" LONG IN THE PRESSURE FLOOR AT RBL 4.50 APPROX 1.25" FWD OF THE F.S. 460 INTERCOSTAL. INDICATION APPEARS TO RUN PARALLEL WITH INTERCOSTALS. FAILS NDT INSP AT THIS TIME. COMPLIED WITH EC/TC REO 601R-53-41-884A BY PERFOSDR IPXA09557736Floorboard · damagedINSPECTION TYPE:C MAIN DECK FLOORBOARD DAMAGED AT EDGES STA 1100-1200, LBL 24-LBL 48. DAMAGED AT FLOORBOARD WAS FOUND TO BE OUT LIMITS PER SRM 53-00-50-FIG 101. FABRICATED NEW FLOORBOARD ON MAE TR NR T9/806375 FROM MATL. P/N A402H PER IPXA EOB757-5320-9692GSDR IPXA09557735Floorboard · damagedINSPECTION TYPE:C MAIN DECK FLOORBOARD DAMAGED AT EDGES STA 1100-1200, LBL 48-LBL 72. DAMAGED AT FLOORBOARD WAS FOUND TO BE OUT OF LIMITS PER SRM 53-00-50 FIG 101. FABRICATED NEW FLOOR BOARD ON MAE TR NR T9/806376 FROM MATL. P/N A402H PER IPXA EO B757-5320-SDR IPXA09557734Floor Panel · damagedINSPECTION TYPE:C MAIN DECK FLOOR BOARD DAMAGED AT EDGES STA 1060 TO 1100, LBL48-LBL72. DAMAGED AT FLOOR BOARD WAS FOUND TO BE OUT OF LIMITS PER SRM 53-00-50 FIG 101. FABRICATED NEW FLOOR BOARD ON MAE TR NR T9/806378 FROM MATL. P/N A402H PER IPXA EO B757-53SDR IPXA09557733Floorboard · damagedINSPECTION TYPE:C MAIN DECK FLOORBOARD DAMAGED AT EDGES STA 1060 TO 1100, LBL24-LBL48. DAMAGE ON FLOORBOARD FOUND TO BE OUT OF LIMITS PER SRM 53-00 50 FIG 101. FABRICATED NEW FLOOR PANEL ON MAE TR NR T9/806379 MATL, P/N A402H PER IPXA EO NR B757-5320-969G.SDR USAA2009111293096Floor Panel · corrodedSAL - S2 - MAJOR REPAIR - CORROSION ON FLOOR PANEL 221FF BETWEEN FR16 TO FR20 & BETWEEN Y1292 TO Y1732. REPLACED FLOOR PANEL 221FF BETWEEN FR16 TO FR20 & BETWEEN Y1292 TO Y1732 IAW JOB CARD 26C22053002.SDR ASAA0976750Splice · corrodedFLOOR PANEL SPLICE BETWEEN FLOORS NR 1 AND 2 CORRODED. REMOVED AND REPLACED FLOOR PANEL SPLICE.SDR IPXA09557563Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557562Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557561Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557560Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557559Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557558Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557557Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557556Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557555Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL P/N 141N5410-15 DAMAGED. REPAIRED PER EO B757-5320-9692-G.SDR IPXA09557619Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO BAY, LBL 30, FLOOR PANEL FWD END, PALLET STA 14 IS DAMAGED. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G AND MM 25-56-03-4.SDR IPXA09557584Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO BAY LBL 30 FLOOR PANEL FWD END PALLET STA 13 IS DAMAGED. REMOVED AND REPLACED FLOOR PANEL PALLET STATION 13 LBL 30 PER IPXA EO 757-5320-9692-G.SDR CA091013002Floor Panel · corroded(CAN) WHEN COMPLYING WITH SB 737-53-1285 MAJOR CORROSION WAS NOTED IN THE SAME AREA THAT HAD ALREADY BEEN INSPECTED BY 3 C-CHECK TASK CARDS. AREA IN QUESTION IS REAR WET FLOOR AREA. STATES ON THE CLIENTS TASK CARD THAT REMOVAL OF SEALANTS, CORROSION INHIBITOSDR IPXA09557571Floor Panel · delaminatedINSPECTION TYPE:N/A PANEL 143N5457-3 DELAMINATED BEYOND REPAIR. FABRICATED FLOOR PANEL IAW B757-5320-9692-G.SDR IPXA09557570Floor Panel · damagedINSPECTION TYPE:N/A PANEL 143N5457-5 ON MCD DAMAGED. FABRICATED NEW FLOORBOARD PANEL PER EOB757-5320-9692-G.SDR IPXA09557537Floor Panel · damagedINSP TYPE: C, DAMAGED TOP SKIN OF FLOOR PNL ON MAIN CARGO DECK STA. 878-900 LBL45-61. REMOVED DAMAGED FLOOR PANEL BET STA 878-9002) FAB. NEW FLOOR PANEL ON MAE TRAV NR T9/805673, PN UP143N5457-99 USING A402H, BATCH NR 1654769, PO NR MST27652 IAW UPS EO. NR B7SDR IPXA09157500Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL 132PG DAMAGED. REPAIRED PER EO A300-5320-16407-C.SDR FDEA200909283407Floor Panel · corrodedCABIN: STA 1705, LBL 51.0 INCHES, UPPER DECK PLATE HAS CORROSION. REPAIR CARRIED OUT IAW EA F-5320-133410. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283406Floor Panel · corrodedSTA 1715, RBL 36.5 INCHES, UPPER DECK PLATE CORROSION. REPAIR CARRIED OUT IAW EA F-5320-133410. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR FDEA200909283405Floor Panel · corrodedBS 1715, RBL 10 INCHES UPPER DECK PLATE HAS CORROSION. REPAIR CARRIED OUT IAW EA F-5320-133410. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.SDR F3LA2009100500195Floor Panel · corrodedDURING C6 C-CHECK, INSP NOTED THE L2 ENTRY DOOR FLOOR PANEL HAS SEVERAL SPOTS OF CORROSION AROUND FASTENER HOLES. MX REMOVED AND REPLACED THE FLOOR PANEL AT POSITION 261FF, IAW TASK CARD C534103-02.SDR ASAA0976712Splice · corrodedFLOOR PANEL SPLICE BETWEEN NR 3 AND NR 4 CORRODED. FABRICATED REPLACEMENT FLOOR PANEL SPLICE.SDR IPXA09557539Floor Panel · corrodedINSPECTION TYPE:C1 AFT CARGO BAY NR 2 FLOOR PANEL HAS CORROSION. REMOVED & REPLACED PER SRM 53-00-53-1A1, 51-40-08-0G.SDR IPXA09557466Floorboard · damagedINSPECTION TYPE:N/A FLOORBOARD DAMAGED. REPAIRED FLOORBOARD.SDR IPXA09557549Floorboard · damagedINSPECTION TYPE:C1 EFN 43320001011 MCD FLOOR PANEL B/S 900-1060, LBL 0-25, TOOL MARKS ON LOWER SURFACE AND DAMAGE AROUND EDGES. REQUIRES REPAIR VALIDATION. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G AND AMM 25-55-04-4.SDR IPXA09557548Floorboard · damagedINSPECTION TYPE:C1 EFN 43300010/0 MCD FLOOR BOARD BS 1020-1060 LBL 25-45 TOOL MARKS AND PUNCTURES ON LOWER SURFACE AND EDGES DAMAGED. REQUIRES REPAIR VALIDATION. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G AND AMM 25-55SDR IPXA09557470Floor Panel · damagedINSPECTION TYPE:C1 EFN 43320001015 MCD FLOOR PANEL BS 1020-1060 RBL 0-25 TOOL MARKS ON LOWER SURFACE EDGES AND CORNERS DAMAGED. REQUIRES REPAIR VALIDATION. FABRICATED REPLACEMENT FLOOR PANEL IN ACCORDANCE WITH EO B757-5320-9692-G.SDR IPXA09557538Floor Panel · crackedINSPECTION TYPE:C1 EFN 4330001008 MCD FLOOR PANEL BS 900-1020 LBL 25-45 NUMEROUS CRACKS & TOOL MARKS ON LOWER SURFACE AND EDGE DAMAGED REQUIRES REPAIR VALIDATION. REMOVED AND REPLACED EO B757-5320-9692.SDR IPXA09557535Floor Panel · damagedINSPECTION TYPE:C1 EFN 43320001019 MCD FLOOR PANEL BS 1060-1100 LBL 25-45 FWD I/B CORNER DAMAGED REQUIRES REPAIR VALIDATION. REMOVED, FABRICATED AND INSTALLED REPLACEMENT PANEL PER EO B757-5320-9692-G.SDR IPXA09557469Floor Panel · damagedINSPECTION TYPE:C-1 EFN 43320001012 MCD FLOOR PANEL BS 900-1060 RBL 0-25 TOOL MARKS ON LOWER SURFACE EDGES AND CORNERS DAMAGED. REQUIRES REPAIR VALIDATION. FABRICATED NEW FLOOR PANEL PER EO B757-5320-9692.SDR IPXA09557468Floor Panel · damagedINSPECTION TYPE:C-1 EFN 43320001017 MCD FLOOR PANEL BS 1100-1200 LBL 0-25, 2 EA INSETS MISSING OR DAMAGED AT FWD O/B CORNER. REQUIRES REPAIR VALIDATION. FABRICATED NEW FLOOR PANEL PER ER B757-5320-96-G.SDR IPXA09557452Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO BAY FLOOR PANEL BS 1000-1040 LBL 45-60 WL 208 HAS 1 DAMAGED INSERT. REPLACED INSERT PER SRM ADDENDUM B757-5320-9692-G.SDR IPXA09557451Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO BAY FLOOR PANEL BS 900-1000 LBL 45-60 WL 208 HAS 1 DAMAGED INSERT. REPLACED INSERT PER SRM ADDENDUM B757-5320-9692-G.SDR IPXA09557450Floor Panel · damagedINSPECTION TYPE:C1 MAIN CARGO BAY FLOOR PANEL BS 900-1000 LBL 45-60 WL 208 HAS 7 DAMAGED INSERTS. REPLACED INSERTS PER SRM ADDENDUM B757-5320-9692-G.SDR IPXA09657495Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1425 TO 1540 LBL 55 TO LBL 77. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09557454Floor Panel · corrodedINSPECTION TYPE:C2 CORROSION ON NR 3 FLOOR PANEL IN FWD CARGO BAY. REMOVED, FABRICATED, AND INSTALLED PER SRM 53-00-53.SDR IPXA09557428Floor Panel · corrodedINSPECTION TYPE:C2 FWD CARGO NR 4 FLOOR PNL HAS AREAS OF CORROSION ON UPPER SURFACE AT MBA SYS CONTACT POINTS. FABRICATED REPLACEMENT FCB NR 4 FLOOR PANEL IAW SRM 51-40-05-0G.
Back to JASC 5321