What was found
INSPECTION TYPE:C-2 AFT CARGO COMPARTMENT NR 4 FLOOR PANEL HAS CORROSION UNDER THE MBA SYSTEM, AND MBA SYSTEM HOLD DOWN ARMS. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT AFT CARGO COMPARTMENT NR 4 FLOOR PANEL IAW SRM 53-60-53-01 & MM 25-50-04-4.