JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA200909023245Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PLATE SPLICE STRAP AT BS 1470 FOUND CORRODED. REMOVED AND REPLACED IAW AMM 25-50-04 REV. 4. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100.SDR FDEA200909023244Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PLATE SPLICE STRAP AT BS 1510 FOUND CORRODED. REMOVED AND REPLACED IAW AMM 25-50-04 REV. 4. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.SDR FDEA200909023242Floor Panel · dentedAFT CARGO COMPARTMENT FLOOR PLATE AT BS 1470 TO BS 1510 FOUND CORRODED AND WITH NUMEROUS DENTS. AT BS 1470 TO BS 1510 FLOOR PLATE REMOVED IAW AMM 25-50-04, REV 4. FLOOR PLATE EVALUATED AND FOUND OUT OF LIMIT IAW SRM 53-00-53 REV 97. FLOOR PLATE FABRICATED ISDR FDEA200909023241Floor Panel · dentedAFT CARGO COMPARTMENT FLOOR PLATE AT BS 1330 TO BS 1470 FOUND CORRODED AND WITH NUMEROUS DENTS. EVALUATE AND RECTIFY. AT BS 1330 TO BS 1470 REMOVED IAW AMM 25-50-04 REV 4. FLOOR PLATE EVALUATED AND FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53 REV 97. FLOOR PSDR FDEA200909023240Floor Panel · dentedAFT CARGO COMPARTMENT FLOOR PLATE AT BS 1510 TO BS 1640 FOUND CORRODED AND WITH NUMEROUS DENTS. REMOVED IAW AMM 25-50-04 REV 4. FOUND OUT OF LIMIT IAW SRM 53- 00-53 REV 97. FLOOR PLATE FABRICATED IAW DWG NR 453N1270 SHT 42 REV -AND PART MARK IAW GMM 7-SDR FDEA200909013213Floor Panel · corrodedFWD CARGO COMPT FLOOR PLATE FROM BS 750 TO BS 843 FOUND CORRODED AND WITH NUMEROUS DENTS. CORRODED FLOOR PLATES REMOVED AND REPLACED IAW EO E F-2550-7-5000 A1-P1. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200909013212Floor Panel · corrodedFWD CARGO COMPT FLOOR PLATE FROM BS 653 TO BS 750 FOUND CORRODED AND WITH NUMEROUS DENTS. CORRODED FLOOR PLATES REMOVED AND REPLACED IAW EO F-2330-7-5000 A1 PT. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.SDR FDEA200909013211Floor Panel · corrodedFWD CARGO COMPT FLOOR PLATE FROM BS 550 TO BS 653 FOUND CORRODED AND WITH NUMEROUS DENTS. CARGO FLOOR PANELS REPLACED IAW EA NRF-2550-132604 (TITLE : CARGO COMPARTMENT - FABRICATE NEW CARGO FLOOR PANELS). REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERISDR F3LA2009090100150Floor Panel · corrodedDURING C6 C-CHECK, INSP NOTED THE R2 ENTRANCE FLOOR PANEL 262FF IS CORRODED AROUND MOUNT HOLES. MX REMOVED AND REPLACED PANEL WITH A SERVICEABLE PANEL.SDR FDEA200908313187Floorboard · puncturedMAIN CABIN FLOORBOARD 242 SF IS PUNCTURED AND CRUSHED FROM FRAME 38.2 TO FRAME 40. REMOVED PANEL 242 SF AMM 53-10-23-4. FABRICATED NEW PANEL IAW DWG SRZ 25-005, REV "H". PART MARKED IAW GMM 7-0-1000. INSTALLED PANEL REF AMM 53-10-23-4.SDR FDEA200908313186Floorboard · puncturedMAIN CABIN FLOORBOARD 242 MF IS PUNCTURED AND CRUSHED FROM FRAME 37 TO FRAME 38.2. REMOVED PANEL 242 MF REF AMM 53-10-23-4. FABRICATED NEW PANEL IAW DWG SRZ 25-005, REV "H". PART MARKED IAW GMM 7-0-1000. INSTALLED PANEL AMM 53-10-23-4.SDR FDEA200908313184Floorboard · puncturedMAIN CABIN FLOORBOARD 242 GF IS PUNCTURED AND CRUSHED FROM FRAME 34 TO FRAME 37. REMOVED PANEL (242 GF) AMM 53-10-23-4. FABRICATED NEW PANEL IAW (DWG SRZ 25-005, REV "H"). PART MARKED IAW GMM 7-0-1000. INSTALLED PANEL IAW AMM 53-10-23-4.SDR FDEA200908313183Floorboard · puncturedMAIN CABIN FLOORBOARD 242 BF IS PUNCTURED AND CRUSHED FROM FRAME 31 TO FRAME 34. REMOVED PANEL 242 BF REF AMM 53-10-23-4. FABRICATED NEW PANEL IAW DWG SRZ 25-005, REV "H". PART MARKED PANEL IAW GMM 7-0-1000. INSTALLED PANEL REF AMM 53-10-23-4.SDR FDEA200908313182Floorboard · puncturedMAIN CABIN FLOORBOARD 232 YG IS PUNCTURED AND CRUSHED FROM FRAME 28 TO FRAME 30. REMOVED PANEL (232 YG) AMM 53-10-23-4. FABRICATED NEW PANEL IAW (DWG SRZ 25-005, REV "H"). PART MARKED IAW GMM 7-0-1000. INSTALLED PANEL AMM 53-10-23-4.SDR FDEA200908313181Floorboard · puncturedMAIN CABIN FLOORBOARD 242 TH IS PUNCTURED AND CRUSHED FROM FRAME 40 TO FRAME 43. FABRICATED NEW FLOOR PANEL 241TH IAW DWG SRZ 25-005, REV "H". INSTALLED PANEL IAW AMM 53-10-23-4.SDR FDEA200908313180Floorboard · puncturedMAIN CABIN FLOORBOARD 242 QJ IS PUNCTURED AND CRUSHED FROM FRAME 40 TO FRAME 43. FABRICATED NEW PANEL IAW (DWG SRZ 25-005, REV "H"). PART MARKED IAW GMM 7-0-1000. INSTALLED PANEL IAW AMM 53-10-23-4.SDR FDEA200908313179Floor Panel · puncturedMAIN CABIN FLOORBOARD 242 UJ IS PUNCTURED AND CRUSHED FROM FRAME 43 TO FRAME 47. REMOVED DAMAGED FLOOR PANEL 242 UJ. FABRICATED NEW FLOOR PANEL 242 UJ, IAW DWG SRZ 25-005, REV "H". INSTALLED PANEL IAW AMM 53-10-23-4.SDR FDEA200908313178Floorboard · puncturedMAIN CABIN FLOORBOARD 241 AJ IS PUNCTURED AND CRUSHED FROM FRAME 47 TO FRAME 51. FABRICATED FLOORBOARD IAW (DWG SRZ 25-005, REV "H"). PART MARKED FLOORBOARD IAW GMM 7-0-1000.SDR FDEA200908313177Floorboard · puncturedMAIN CABIN FLOORBOARD 242 AJ IS PUNCTURED AND CRUSHED FROM FRAME 47 TO FRAME 51. LOCATED FASTENER HOLES AND PREPED EDGE FOR POTTING IAW (DWG SRZ 25-005, REV "H"). PART MARKED IAW GMM 7-0-1000.SDR FDEA200908313176Floorboard · puncturedMAIN CABIN FLOORBOARD 242 ZJ IS PUNCTURED AND CRUSHED FROM FRAME 47 TO FRAME 51. FABRICATED FLOORBOARD IAW (DWG SRZ 25-005, REV "H"). PART MARKED FLOORBOARD IAW GMM 7-0-1000.SDR FDEA200908313175Floorboard · puncturedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 EK IS PUNCTURED AND CRUSHED FROM FRAME 51 TO FRAME 54. REMOVED DAMAGED FLOOR PANEL 242 EK. FABRICATED NEW FLOOR PANEL 242 EK, IAW DWG SRZ 25-005, REV "H". INSTALLED PANEL IAW AMM 53-10-23-4.SDR FDEA200908313174Floorboard · puncturedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 251 PH IS PUNCTURED AND CRUSHED FROM FRAME 58 TO FRAME 60. DAMAGED FLOOR PANEL 252 PH REMOVED. NEW PANEL 252 PH FABRICATED AND INSTALLED IAW AMM 53-10-23-4 AND DWG SRZ 25-005, REV "H".SDR FDEA200908313173Floorboard · puncturedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 252 UH IS PUNCTURED AND CRUSHED FROM FRAME 62 TO FRAME 63. DAMAGED FLOOR PANEL (252 UH) REMOVED. NEW PANEL (252 UH) FABRICATED AND INSTALLED IAW AMM 53-10-23-4 AND DWG SRZ 25-005, REV "H".SDR FDEA200908313172Floorboard · puncturedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 251 UH IS PUNCTURED AND CRUSHED FROM FRAME 62 TO FRAME 63. DAMAGED FLOOR PANEL REMOVED. NEW PANEL (251 UH) FABRICATED AND INSTALLED IAW AMM 53-10-23-4 AND DWG SRZ 25-005, REV "H".SDR IPXA09657249Floorboard · damagedINSPECTION TYPE:N/A FLOORBOARD DAMAGED POS 1R. FABRICATED FLOOR IAW B767-5320-9693-F.SDR IPXA09657248Floorboard · damagedINSPECTION TYPE:N/A FLOORBOARD DAMAGED POS 2R. FABRICATED NEW PANEL IAW EO B767-5320-9693-F.SDR IPXA09157353Floorboard · damagedINSPECTION TYPE:5YR AFT PIT FLOORBOARD 152SF HAS EDGE DAMAGED FOUND DURING REMOVAL. FABBED FLOOR PANEL 152 SF IAW UPS EO A300-5320-16407-C, APPX C.SDR IPXA09557237Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL DAMAGED POS 14R-6 DENTS WITH IN 6 INCHES AREA OF EACH OTHER LARGEST BEING 3.5 X 1.00 X .110 INCHES DEF 406612. REPAIRED IAW EO-B757-5320-34787-A.SDR IPXA09557236Floor Panel · damagedINSPECTION TYPE:N/A DAMAGED FLOOR PANEL POS 14L 1.00 X 1.00 X .100 DEF 406611. REPAIRED IAW EO-B757-5320-34789-A.SDR F3LA2009090300152Floor Panel · corrodedDURING DEN C6 C-CHECK, INSPECTION NOTED A CORRODED POTTED INSERT ON THE AFT OUTSIDE EDGE OF FLOOR PANEL 261PF. MAINTENANCE REPAIRED FLOOR PANEL IAW EA A9-53R-31306.SDR UALA2009082702671Floorboard · damagedFLOOR SOFT AT ROWS 9-10. REMOVED AND REPLACED FLOORBOARD AT ROWS 9-10 ON WU K6774D BY AMT'S.SDR IPXA09657123Floor Panel · damagedINSPECTION TYPE:N/A MAIN CARGO DECK FLOOR PANEL POS 7R DAMAGED. REPAIRED PER EO B767-5320-34683-A.SDR IPXA09657122Floor Panel · damagedINSPECTION TYPE:N/A MAIN CARGO DECK FLOOR PANEL POS 6 DAMAGED. REPAIRED PER EO B767-5320-34684-A.SDR IPXA09657121Floor Panel · misrepairedINSPECTION TYPE:N/A MCD POS 9 RT OUTBOARD FLOOR PANEL INTERIM REPAIR. FABRICATED FLOOR PANEL PER EO B767-5320-9693-F.SDR IPXA09657168Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 412 TO 540, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR UALA2009082002559Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR SIDE STRUCTURE PANEL CORRODED RT SIDE JUST AFT OF DOOR OPENING. LIFTED FLOOR PANEL AND INSPECTED AREA UNDER CORROSION AND FOUND NO EVIDENCE OF FURTHER CORROSION. SECURED FLOOR PANEL AFTER INSPECTION. CORR REMOVED AND NEW 'Z' ANGLSDR A6WA200940522Floor Panel · corrodedCORROSION ON 3 PLATES OF CARGO FLOOR STRUCTURE BTWN FS 574 TO FS 621 AND BTWN LBL 27 TO LT SILL. CORROSION REMOVED ON 3 PLATES IAW SRM 51-21-06. (K)SDR IPXA09657175Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 731 TO 833, LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657174Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 540 TO 654+22, RBL 33 TO RBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657173Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 654+22 TO 690, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657165Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1344 TO 1480, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657164Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1207 TO 1344, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657162Floor Panel · crackedINSPECTION TYPE:C MCD FLOOR PANEL FOUND CRACK AT STA 977 TO 1043, LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657172Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 283 TO 412, RBL 55 TO RBL 77. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657171Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 283 TO 412, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657170Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 412 TO 540, LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657169Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 540 TO 654+22, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657167Floor Panel · delaminatedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DELAMINATION AT STA 930 TO 975, LBL 11 TO LBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657166Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1480 TO 1598, RBL 33 TO RBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09657163Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 283 TO 412, RBL 77 RBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.
Back to JASC 5321