JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA09157155Floor Panel · damagedINSPECTION TYPE:3/C FLOOR PANEL 161JF IN BULK PIT REQUIRES REPLACING IAW EO A300-5100-344 94-A. FABBED FLOOR PANEL IAW IPXA EO A300-5320-16407-C, APPX D.SDR IPXA09157154Floor Panel · damagedINSPECTION TYPE:3/C FLOOR PANEL 162HF IN BULKHEAD PITS REQUIRES REPLACING IAW EO A300-510 0-34494-A. FABBED FLOOR PANEL IAW EO A300-5320-16407-C, APPX D.SDR IPXA09657082Floorboard · damagedINSPECTION TYPE:N/A FLOORBOARD POS 8R HAS DAMAGE. REPAIRED IAW EO B767-5320-34623-A.SDR IPXA09657073Floor Panel · damagedINSPECTION TYPE:N/A D-403978 MAIN CARGO DECK POS 2R FLOOR PANEL INTERIM REPAIR. REPLACED PANEL PER EO767-5320-9693-F.SDR FDEA200908143017Floor Panel · delaminatedFWD CARGO COMPARTMENT FLOOR PANEL 131 QF IS DELAMINATED. FABRICATED FLOOR PANEL 131 QF IAW DWG SRZ 25-005, REV "H".SDR IPXA09157101Floorboard · damagedINSPECTION TYPE:4C TRANSFERRED FROM LOG PAGE 207895 ITEM 1, BULK CARGO COMPARTMENT FLOOR HAS TWO AREAS OF DAMAGE REF D-404998. FABRICATED BULK CARGO FLOORBOARDS 161HF AND 162HF PER EO A300-5320- 16407-C APPENDIX D.SDR IPXA09157100Floorboard · misrepairedINSPECTION TYPE:4C MAIN CARGO COMPARTMENT FLOORBOARD 251BN PREVIOUS REPAIR NOT PER SRM STANDARDS. REPLACE FLOORBOARD PER EO A300-5320-16407-C. FABRICATED MAIN CARGO FLOORBOARD 251BN PER EO A300-5320-16407-C APPENDIX B.SDR IPXA09157099Floorboard · misrepairedINSPECTION TYPE:4C MAIN CARGO COMPARTMENT FLOORBOARD 252UJ PREVIOUS REPAIR NOT PER SRM STANDARDS. REPLACE FLOORBOARD REF EO A300-5320-16407-C. FABRICATED MAIN CABIN FLOORBOARD 252UJ PER EO A300-5320-16407-C APPENDIX B.SDR IPXA09157098Floorboard · misrepairedINSPECTION TYPE:4C BULK CARGO COMPARTMENT FLOORBOARD 161JF PREVIOUS REPAIR NOT PER SRM STANDARDS. REPLACE FLOORBOARD REF EO A300-5320-16407-C. FABRICATED FLOORBOARD 161JF PER EO A300-5320-16407-C APPENDIX D.SDR FDEA200908102967Floor Panel · damagedFLOOR PANEL 242 VG HAS THE END OF THE PANEL BROKEN OFF. FABRICATED NEW FLOOR PANEL IAW DWG SRZ 25-005, REV "H".SDR F3LA2009081400132Floor Panel · corrodedDURING DEN C4 C-CHECK, INSP NOTED THE FWD CARGO COMPARTMENT FLOOR PANEL FWD OF FRAME 34 AT THE AFT BULKHEAD HAS CORROSION AROUND NUT PLATES. MX REMOVED AND REPLACED THE FLOOR PANEL SUPPORT PLATE IAW A319 SRM 51-42-11 AND 51-44-11.SDR FDEA200908072963Floorboard · dentedAFT CARGO PIT BALLMAT PANEL 151 RF IS PUNCTURED ON THE BOTTOM SIDE. REMOVED OLD SKIN IAW SRM 51-40-21; PARA 6 & 13. DRILLED NEW SKIN IAW SRM 51-72-10, PG 2. ALODINED IAW SRM 51-21-10, PG 1. PRIMED & PAINTED IAW SRM 51-23-10, PG 1. INSTALLED SKIN IAW SRM 5SDR FDEA200908072962Floorboard · dentedAFT CARGO PIT BALLMAT PANEL 1561 MF HAS BULGES ON THE BOTTOM SKIN. REMOVED OLD SKIN IAW SRM 51-40-21; PARA 6 & 13. DRILLED NEW SKIN IAW SRM 51-72-10, PG 2. ALODINED IAW SRM 51-21-10, PG 1. PRIMED & PAINTED IAW SRM 51-23-10, PG 1. INSTALLED SKIN IAW SRM 5SDR FDEA200908072943Floorboard · damagedFWD CARGO COMPARTMENT BALL MAT 132 XG IS DAMAGED. REMOVED PROFILE IAW SRM 51-72-10, PARA 5A. LOCATED & DRILLED PROFILE IAW SRM 51-72-10, PARA 6A. TOP COATED IAW SRM 51-23-10. INSTALLED PROFILE IAW SRM 51-72-10, PARA 6. APPLIED NON-SKID IAW SRM 51-23-10.SDR IPXA09557027Floorboard · damagedINSPECTION TYPE:C MAIN DECK FLOORBOARD DAMAGED ON EDGES STA 1020 TO 1060 BL 0 TO RBL 25. FAB NEW FLOORBOARD ON MAE TRAVELER T9/801158 USING A402H BATCH 1333430 PO CUSTOMER SUPPLIED AND UPS EO B757-5320-9692-G.SDR IPXA09557026Floorboard · damagedINSPECTION TYPE:C MAIN DECK FLOORBOARD DAMAGED ON EDGES STA 1020 TO 1060, LBL 24 TO LBL 45. FABBED FLOORBOARD ON MAE TRAVELER T9/801160 USING A402H BATCH 1333430 PO CUSTOMER SUPPLIED AND UPS EO B757-5320-9692-G.SDR IPXA09557025Floorboard · damagedINSPECTION TYPE:C MAIN DECK FLOORBOARD DAMAGED ON EDGES STA 1060 TO 1100 BL 0 TO RBL 25. FABRICATED NEW FLOORBOARD ON MAE TRAVELER T9/801159 USING A402H BATCH 1333430 PO CUSTOMER SUPPLIED AND UPS EO B757-5320-9692-G.SDR IPXA09557057Floorboard · damagedINSPECTION TYPE:C1 EXISTING REPAIRS COULD NOT BE VERIFIED AS SRM REPAIRS. REMOVE AND REPLACE PER EO B757-5320-9692G.SDR IPXA09557056Floorboard · damagedINSPECTION TYPE:C1 EXISTING REPAIRS COULD NOT BE VERIFIED AS SRM REPAIRS. REMOVE AND REPLACE PER EO B757-5320-9692G.SDR IPXA09557055Floorboard · damagedINSPECTION TYPE:C1 EXISTING REPAIRS COULD NOT BE VERIFIED AS SRM REPAIRS. REMOVE AND REPLACE PER EO B757-5320-9692G.SDR IPXA09557054Floorboard · damagedINSPECTION TYPE:C1 EXISTING REPAIRS COULD NOT BE VERIFIED AS SRM REPAIRS. REMOVE AND REPLACE PER EO B757-5320-9692G.SDR IPXA09557053Floorboard · damagedINSPECTION TYPE:C1 EXISTING REPAIRS COULD NOT BE VERIFIED AS SRM REPAIRS. REMOVE AND REPLACE PER EO B757-5320-9692G.SDR IPXA09656986Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 731 TO 833, RBL 55 TO RBL 77. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656974Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 690 TO 731, RBL 55 TO RBL 77. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656973Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 654+22 TO 690, RBL 55 TO RBL 77. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR DLM88091331Floor Panel · corrodedFWD WET AREA FLOOR PANEL 160G HAS CORROSION. REPLACED PANEL IAW SRM 51-10-4.SDR IPXA09656983Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 654+22 TO 690, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656982Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 690 TO 731, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656981Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 1114 TO 1197+22 RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656980Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 833 TO 930, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656979Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 833 TO 930 RBL 33 TO RBL 55. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656978Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 1197+22 TO 1207 RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656977Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH & GOUGE AT STA 1380 TO 1480 RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656976Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 833 TO 930, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656975Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 731 TO 833, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656972Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 930 TO 975, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR IPXA09656971Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1114 TO 1197+22 LBL 11 TO RBL 11. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656970Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 1480 TO 1598, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656969Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 1207 TO 1320, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR IPXA09656968Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 873 TO 932, RBL 77 TO RBL 88. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656966Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 975 TO 1114, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR IPXA09656965Floor Panel · gougedINSPECTION TYPE:C MCD FLOOR PANEL FOUND SCRATCH AND GOUGE AT STA 1320 TO 1380 RBL 11 TO RBL 33. FLOOR PNL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR FDEA200908032877Floor Panel · crackedFLOOR PANEL IS CRACKED FROM FRAME 51 TO FRAME 54; APPROX LBL 20. FABRICATED FLOORBOARD IN REF TO DWG SRZ 25-005, REV "H".SDR FDEA200908032876Floor Panel · damagedMAIN CABIN FLOOR PANEL 262 YF IS DAMAGED FROM FRAME 78 TO FRAME 79 AND FROM RBL 32 TO RBL 45. FABRICATED FLOORBOARD IN REF TO DWG SRZ 25-005, REV "H".SDR FDEA200908032875Floor Panel · crackedCABIN FLOOR PANEL 251 XH FWD END IS CRACKED BETWEEN FRAME 63 & FRAME 64; LBL 96. FABRICATED FLOORBOARD IN REF TO DWG SRZ 25-005, REV "H".SDR IPXA09656925Floor Panel · damagedINSPECTION TYPE:N/A POS 3R FLOOR PANEL DAMAGED. REPAIRED PER EO B767-5320-34455-A.SDR IPXA09157014Floor Panel · damagedINSPECTION TYPE:1C MAIN CARGO DECK FLOOR PANEL 242DQ REQUIRES REMOVAL AND REPLACEMENT IAW EO A300-5320-16407-C. FABRICATED FLOOR PANEL 242DQ PER EO A300-5320-16407-C APPENDIX B.SDR IPXA09656911Floor Panel · damagedINSPECTION TYPE:N/A FLOOR PANEL 9C DAMAGED. FABRICATED NEW FLOOR PANEL.SDR IPXA09157013Floor Panel · damagedINSPECTION TYPE:1C BULK CARGO FLOOR PANEL 161HF REQUIRES REMOVAL AND REPLACEMENT IAW A300-5320-16407-C. FABRICATED FLOOR PANEL 161HF PER EO A300-5320-16407-C APPENDIX D.SDR IPXA09656985Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 975 TO 1114, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.
Back to JASC 5321