JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA09656984Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1197+22 TO 1207 RBL 55 TO RBL 77. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53-01-01.SDR IPXA09656967Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 654+22 TO 690, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED PER EO B767-5320-9693-F & INSTALLED AS PER MM 53- 01-01.SDR AALA20090731TUL01Floor Skin · corrodedTUL - CORROSION ON FLOOR SKIN FROM LEFT BUTTLINE 0 TO LEFT BUTTLINE 54. INSTALLED REPAIR UNDER SRM 53-60-51-2R ALT 11.SDR FDEA200907272789Floorboard · puncturedPARTS RACK, FWD CARGO COMPARTMENT BALLMAT 132DF, BOTTOM SKIN IS PUNCTURED. REMOVED & REINSTALLED BALL UNIT IAW AMM 25-52-23-4, PARA 3B & 3D. REMOVED BOTTOM SKIN & SEATING LEDGES IAW SRM 51-72-10, PARA 5. LOCATED & DRILLED BOTTOM SKIN 51-72-10, PARA 6A. SDR FDEA200907272788Floorboard · puncturedPARTS RACK, FWD CARGO COMPARTMENT BALLMAT 132XG, BOTTOM SKIN IS PUNCTURED. REMOVED & REINSTALLED BALL UNITS IAW AMM 25-52-23-4, PARA 3B & 3D. REMOVED BOTTOM SKIN & SEATING LEDGES IAW SRM 51-72-10, PARA 5A. BOTTOM SKIN ID 2024-T3 ,0.025 IAW DWG A25771864SDR FDEA200907272787Floorboard · puncturedFWD CARGO COMPARTMENT BALLMAT 132SG, BOTTOM SKIN IS PUNCTURED. REMOVED BOTTOM SKIN IAW SRM 51-72-10, PARA 5A. BOTTOM SKIN MATERIAL ID 2024-T3, 0.025 IAW AIRBUS DWG A25771864. LOCATED & DRILLED IAW SRM, 51-72-10, PARA 6A. ALODINED IAW SRM 51-21-10, PG 3, SDR FDEA200907272786Floorboard · puncturedFWD CARGO COMPARTMENT BALL MAT 132TG, BOTTOM SKIN IS PUNCTURED. DRILLED & DEBURRED SKIN IAW DWG 10A25771870, ISSUE "F". ALODINED; PRIMED & TOP COATED IAW A300-600 SRM 51-21-10, PG 6 & 51-23-10, PG 5. INSTALLED SKIN; SEATING LEDGES & BALL UNITS IAW SRM 51- SDR FDEA200907272785Floorboard · puncturedPARTS RACK, FWD CARGO COMPARTMENT FLOORBOARD 132RF TOP SKIN IS PUNCTURED. REPAIRED FLOOR PANEL IAW DWG SRZ 25-005; REV "H".SDR FDEA200907272784Floorboard · damagedPARTS RACK, FWD CARGO COMPARTMENT FLOORBOARD 131 RF HAS EDGE DAMAGE. REPAIRED FLOOR PANEL IAW DWG SRZ 25-005; REV "H".SDR FDEA200907272783Floorboard · crackedPARTS RACK, FWD CARGO COMPARTMENT FLOORBOARDS 132HG IS CRACKED. FABRICATED NEW FLOOR PANEL 132 HG IAW DWG SRZ 25-005, REV "H".SDR FDEA200907272782Floorboard · damagedPARTS RACK, FWD CARGO COMPARTMENT FLOORBOARD 132YF HAS A DAMAGED CORNER. REPAIRED IAW DWG SRZ 25-005; REV "H".SDR FDEA200907272781Floorboard · puncturedPART RACK, FWD CARGO COMPARTMENT FLOORBOARD 132JG BOTTOM IS PUNCTURED. REPAIRED IAW DWG SRZ 25-005; REV "H".SDR FDEA200907272780Floorboard · puncturedPARTS RACK, FWD CARGO COMPARTMENT FLOORBOARD 132ZF BOTTOM IS PUNCTURED. REPAIRED IAW DWG SRZ 25-005; REV "H".SDR FDEA200907272779Floorboard · damagedPARTS RACK FWD CARGO COMPARTMENT FLOORBOARD 132HG HAS EDGE DAMAGE. REPAIRED IAW DWG SRZ 25-005; REV "H".SDR FDEA200907272778Floorboard · damagedPARTS RACK FWD CARGO COMPARTMENT FLOORBOARD 132ZF HAS EDGE DAMAGE. REPAIRED FLOOR PANEL IAW DWG SRZ 25-005; REV "H".SDR FDEA200907242733Floor Panel · damagedFWD CARGO FLOOR PANEL 132 QF HAS SOFT SPOTS. FABRICATED NEW FLOOR PANEL 132 QF IAW DWG SRZ 25-005, REV "H".SDR FDEA200907242732Floor Panel · damagedFWD CARGO FLOOR PANEL 131 QF HAS SOFT SPOTS. FABRICATED NEW FLOOR PANEL 131 QF IAW DWG SRZ 25-005, REV "H".SDR IPXA09156834Floor Panel · crackedINSPECTION TYPE:5YR MAIN CABIN FLOOR PANEL 242LM IS CRACKED. FABRICATED FLOORBOARD 242LM PER EO A300-5320-16407-C APP B.SDR IPXA09156824Floor Panel · crackedINSPECTION TYPE:5YR MAIN CABIN FLOOR PANEL 241YH IS CRACKED. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156823Floor Panel · crackedINSPECTION TYPE:5YR MAIN CABIN FLOOR PANEL 231QH IS CRACKED AT THE FORWARD END. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156822Floor Panel · crackedINSPECTION TYPE:5YR MAIN CABIN FLOOR PANEL 241LT IS CRACKED. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156893Floor Panel · misrepairedINSPECTION TYPE:1C MAIN CARGO COMPARTMENT PANEL 242LJ REQUIRES EVALUATION FOR SRM REPAIR OR REPLACEMENT PER EO A300-5320-16407-C. FABRICATED MAIN CARGO FLOOR PANEL 242LJ PER EO A300-5320-16407-C APPENDIX B.SDR IPXA09556849Floor Panel · puncturedINSPECTION TYPE:C1 BULK CARGO NR 2 FLOOR PANEL PUNCTURED 2 PLACES. FABRICATED REPLACEMENT PANEL PER SRM 53-60-53-01.SDR IPXA09656817Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 412 TO 540 RBL 11 TO RBL 33 FOUND GOUGE & DENT MARKS. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656816Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 283 TO 412, RBL 11 TO RBL 33 FOUND SCORE AND DENT MARKS. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656815Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 731 TO 833 LBL 11 TO LBL 33 FOUND SCORE & DENT MARKS. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656813Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 833 TO 930 LBL 55 TO LBL 77 FOUND GOUGE AND DENT MARKS. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656716Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL POS 7 CTR DAMAGED. REPAIRED PER EO B767-5320-34305-A.SDR IPXA09656715Floor Panel · damagedINSPECTION TYPE:N/A MCD FLOOR PANEL POS 10 CTR DAMAGED. REPAIRED PER EO B767-5320-34306-A.SDR IPXA09656713Floor Panel · damagedINSPECTION TYPE:N/A MCD POS 4 CTR FLOOR PANEL DAMAGED. REPAIRED PER EO B767-5320-34304-A.SDR IPXA09156828Floorboard · damagedINSPECTION TYPE:5YR MAIN CABIN CARGO COMPARTMENT FLOORBOARD 252XJ IS PUNCTURED. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156827Floorboard · damagedINSPECTION TYPE:5YR MAIN CABIN CARGO COMPARTMENT FLOORBOARD 251LJ HAS 2 AREAS WITH TEMP REPAIRS. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156826Floorboard · damagedINSPECTION TYPE:5YR MAIN CABIN CARGO COMPARTMENT FLOORBOARD 242EF HAS TEMP REPAIR. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156825Floor Panel · crackedINSPECTION TYPE:5YR MAIN CABIN CARGO COMPARTMENT FLOOR PANEL 252VF CRACKED 2 AREAS. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156821Floorboard · crackedINSPECTION TYPE:5YR MAIN CARGO COMPARTMENT FLOORBOARD 252BN CRACKED AT CENTER AND FORWARD RIGHT SIDE. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156820Floorboard · gougedINSPECTION TYPE:5YR MAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 RM HAS GOUGE MARKS FWD LEFT SIDE. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09656819Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 246 TO 412 RBL 55 TO RBL 77 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656818Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 690 TO 731, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656814Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 412 TO 540 RBL 33 TO RBL 55 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656812Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 936 TO 985 RBL 77 TO RBL 88 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656811Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 412 TO 540, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656810Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 833 TO 930, LBL 11 TO LBL 33 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656809Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 1460 TO 1540 LBL 55 TO LBL 77 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656808Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 975 TO 1114, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656807Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 412 TO 540, RBL 55 TO RBL 77 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656806Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 1207 TO 1350, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656805Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 540 TO 654+22, LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656804Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 833 TO 930 LBL 11 TO RBL 11 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656803Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 1480 TO 1598 RBL 33 TO RBL 55 FOUND DAMAGED. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.SDR IPXA09656802Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL AT STA 985 TO 1087 LBL 75 TO LBL 88 FOUND POOR CONDITION. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED AS PER AMM 53-01-01.
Back to JASC 5321