SDR IPXA09656641Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 654+22 TO 690 LBL 11 TO LBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656640Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 975 TO 1114 LBL 11 TO LBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656630Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 975 TO STA 1041, LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER SRM 53-01-01.SDR IPXA09656629Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL DAMAGE AT STA 833 TO 930, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656628Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 933 TO STA 970, RBL 11 TO RBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656627Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 833 TO STA 933, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656626Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 1480 TO 1598, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656625Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 970 - 1114 RBL 11 TO RBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656623Floor Panel · damagedINSPECTION TYPE:ETOP MCD FLOOR PANEL FOUND DAMAGE AT STA 540 TO 654+22, LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656622Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 412 TO STA 540, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656621Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 283 TO 412 RBL 55 TO RBL 77. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656620Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 833 TO 933, LBL 11 TO LBL 33. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656619Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 654+22 TO 690, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656618Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 975 TO 1114, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656617Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 412 TO STA 550, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656616Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 936 TO STA 985, RBL 77 TO RBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656615Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 368 TO 412, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656614Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 283 TO STA 412, LBL 11 TO RBL 11. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F.SDR IPXA09656613Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 550 TO STA 654+22, LBL 77 TO LBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656612Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 1207 TO 1344, LBL 33 TO L55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F.SDR IPXA09656611Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 975 TO 1114, LBL 55 TO LBL 77. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656610Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 985 TO STA 1087, RBL 77 TO RBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656609Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 764 TO 876, RBL 77 TO RBL 88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F, AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656608Floor Panel · damagedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND DAMAGE AT STA 1370 - 1480, RBL 77 - R88. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656605Floor Panel · puncturedINSPECTION TYPE:7C MCD FLOOR PANEL PUNCTURE AT STA 970, LBL 48. FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R, FIG 201 REV 44.SDR IPXA09656604Floor Panel · puncturedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND PUNCTURE AT STA 1197, RBL 82. FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R FIG 201 REV 44.SDR IPXA09156647Floorboard · gougedINSPECTION TYPE:4C FLOORBOARD PANEL 131MG HAS SEVERAL EDGE GOUGES AS MARKED. FABRICATED FLOORBOARD PER EO A300-5320-16407-C, APPX C.SDR FDEA200907022458Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD DENTED / CRACKED ZONE Z241; PANEL GK AT FRAME 51. FABRICATED NEW FLOORBOARD 241 GK IAW DWG SRZ 25-005; REV "H".SDR FDEA200907022455Floorboard · damagedFWD CARGO COMPARTMENT FLOORBOARD 132 MG HAS EDGE DAMAGE. FABRICATED FLOOR PANEL 132 MG IAW DWG SRZ 25-005, REV "H".SDR FDEA200907022454Floorboard · damagedFWD CARGO COMPARTMENT FLOORBOARD 132 LG HAS EDGE DAMAGE AND IS MISSING AN INSERT. FABRICATED FLOOR PANEL 132 LG IAW DWG SRZ 25-005, REV "H".SDR FDEA200907022453Floorboard · crackedFWD CARGO COMPARTMENT FLOORBOARD 132 KG CRACKED. FABRICATED FLOOR PANEL 132 KG IAW DWG SRZ 25-005, REV "H".SDR FDEA200907022452Floorboard · puncturedFWD CARGO COMPARTMENT FLOORBOARD 132 NG HAS MULTIPLE PUNCTURES ON THE BOTTOM AND EDGE DAMAGE. FABRICATED FLOOR PANEL 132 NG IAW DWG SRZ 25-005, REV "H".SDR DLM88091235Floor Panel · corrodedR1 DOOR THRESHOLD FLOOR PANEL HAS CORROSION. REPLACED PANEL IAW SRM 51-10-4.SDR IPXA09156482Floor Panel · damagedMCD POS 12 RT FLOOR PANEL DAMAGED REF D398771. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-16407-C.SDR FDEA200906292382Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 252 VF IS CRACKED. FABRICATED FLOORBOARD 252 VF IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD 252 VF IAW AMM 53-10-25-4. INSTALLED FLOORBOARD 252 ZF IAW AMM 53-10-25-4.SDR FDEA200906292381Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 252 ZF IS CRACKED. FABRICATED FLOORBOARD 252 ZF IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD 252 ZF IAW AMM 53-10-25-4. INSTALLED FLOORBOARD 252 ZF IAW AMM 53-10-25-4.SDR FDEA200906292380Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 252 UF IS CRACKED. FABRICATED FLOORBOARD 252 UH IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD 252 UH IAW AMM 53-10-25-4.SDR FDEA200906292379Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 232 YG IS DENTED/CRACKED. REPAIRED MAIN CABIN FLOORBOARD 232 YG BY FABRICATING A NEW FLOORBOARD USING THE OLD FLOORBOARD AS A TEMPLATE; POTTED EDGE; DRILLED; INSTALLED INSERTS; SANDED; CLEANED; INSTALLED ANTI-SKID TAPE SDR FDEA200906292378Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 232 BF IS DENTED / CRACKED. FABRICATED FLOOR PANEL 242 BF IAW DWG SRZ 25-005, REV "H". REMOVED AND REPLACED 242 BF IAW AMM 53-10-25-4.SDR FDEA200906292377Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 GF IS DENTED/CRACKED. FABRICATED FLOOR PANEL 242 GF IAW DWG SRZ 25-005, REV "H". REMOVED AND REPLACED 242 GF IAW AMM 53-10-25-4.SDR FDEA200906292376Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 MF IS DENTED/CRACKED. FABRICATED FLOOR PANEL 242 MF IAW DWG SRZ 25-005, REV "H". REMOVED AND REPLACED 242 MF IAW AMM 53-10-25-4.SDR FDEA200906292375Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 SF IS DENTED/CRACKED. FABRICATED MAIN CABIN FLOOR BOARD 242 SF USING THE OLD BOARD AS A TEMPLATE; POTTED EDGE; DRILLED; INSTALLED INSERTS; SANDED AND CLEANED; INSTALLED ANTI-SKID TAPE AND PART MARKED IAW DWG SRZ 25SDR FDEA200906292374Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 QJ IS DENTED/CRACKED. FABRICATED NEW FLOOR PANEL 242 QJ IAW DWG SRZ 25-005; REV "H".SDR FDEA200906292373Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 UJ IS DENTED/CRACKED. FABRICATED NEW FLOOR PANEL 242 UJ IAW DWG SRZ 25-005; REV "H".SDR FDEA200906292372Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 ZJ IS DENTED/CRACKED. FABRICATED NEW FLOOR PANEL IAW DWG SRZ 25-005; REV "H". ALL WORK WAS ACCOMPLISHED ON N/R N00168.SDR FDEA200906292371Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 EK IS DENTED/CRACKED. REPAIRED MAIN CABIN FLOORBOARD 242 EK BY FABRICATING A NEW BOARD USING THE OLD BOARD AS A TEMPLATE; POTTED EDGE; DRILLED; INSTALLED INSERTS; SANDED AND CLEANED; INSTALLED ANTI-SKID TAPE AND PASDR FDEA200906292370Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 RG IS DENTED. FABRICATED FLOOR BOARD 242 RG IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD 242 RG IAW AMM 53-10-25-4. ALL WORK WAS ACCOMPLISHED ON N/R N00166.SDR FDEA200906292369Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 ZJ IS CRACKED. FABRICATED NEW FLOOR PANEL IAW DWG SRZ 25-005; REV "H".SDR FDEA200906292368Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 EK IS CRACKED. REPAIRED MAIN CABIN FLOOR BOARD 242 EK BY FABRICATING A NEW BOARD USING THE OLD BOARD AS A TEMPLATE; POTTED EDGE; DRILLED; INSTALLED INSERTS; SANDED AND CLEANED; INSTALLED ANTI-SKID TAPE AND PART MASDR FDEA200906292367Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 RG IS CRACKED. FABRICATED FLOORBOARD 242 RG IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD 242 RG IAW AMM 53-10-25-4.
Back to JASC 5321