SDR FDEA200906292366Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 242 VG IS CRACKED. FABRICATED FLOOR PANEL 242 VG IAW DWG SRZ 25-005, REV "H". INSTALLED FLOOR PANEL 242 VG IAW AMM 53-10-25-4.SDR FDEA200906292365Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 252 BF IS CRACKED. FABRICATED FLOORBOARD 252 BF IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD 252 BF IAW AMM 53-10-25-4.SDR FDEA200906292364Floorboard · crackedMAIN CABIN CARGO COMPARTMENT FLOORBOARD 252 GF IS CRACKED. FABRICATED FLOORBOARD 252 GF IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD 252 GF IAW AMM 53-10-25-4.SDR FDEA200906292363Floorboard · crackedMAIN CARGO COMPARTMENT FLOORBOARD 252 PH IS CRACKED. FABRICATED FLOORBOARD 252 PH IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD 252 PH IAW AMM 53-10-25-4.SDR FDEA200906292361Floorboard · crackedMAIN CARGO COMPARTMENT FLOORBOARD 251 NG IS CRACKED. FABRICATED FLOOR PANEL 251 RT IAW DWG SRZ 25-005, REV "H". INSTALLED FLOOR PANEL 251 RT IAW AMM 53-10-25-4.SDR FDEA200906292360Floorboard · crackedMAIN CARGO COMPARTMENT FLOORBOARD IS DENTED/CRACKED, ZONE Z241, PANEL HK AT FRAME 53. FABRICATED FLOOR PANEL 241 HF IAW DWG SRZ 25-005, REV "H". INSTALLED FLOOR PANEL 241 HF IAW AMM 53-10-25-4.SDR FDEA200906292359Floorboard · damagedMAIN CARGO COMPARTMENT FLOORBOARD IS SPONGY, ZONE Z241, PANEL AJ AT FRAME 46. FABRICATED NEW FLOORBOARD 241 AJ IAW SRZ 25-005 REV "H". REMOVED AND REPLACED FLOOR PANEL 241 AJ IN REF TO AMM 53-10-23-4. PART MARKED PANEL IN REF TO GMM 7-0-1001.SDR FDEA200906292358Floorboard · crackedMAIN CARGO COMPARTMENT FLOORBOARD IS DENTED/CRACKED. ZONE Z241 PANEL WH AT FRAME 46. FABRICATED NEW FLOOR PANEL 241 WH IAW DWG SRZ 25-005; REV "H".SDR FDEA200906292357Floorboard · puncturedMAIN CARGO COMPARTMENT FLOORBOARD IS PUNCTURED AT FRAME 31, LBL 52. FABRICATED FLOORBOARD 241 MJ IAW DWG SRZ 25-005, REV "H". INSTALLED FLOORBOARD 241 MJ IAW AMM 53-10-25-4.SDR ASAA0996028Floorboard · dentedFLOORBOARD IS DENTED AND GOUGED ACB NR 4. REPLACED FLOORBOARD.SDR IPXA09156479Floor Panel · damagedPOS 11 AFT RT FLOORBOARD DAMAGED 2 INCHES FROM POS 12 REF D398770. FABRICATED NEW FLOORBOARD PER EO A300-5320-16407C.SDR IPXA09156478Floor Panel · damagedMAIN CARGO DECK FLOOR DAMAGED AT POSITION 12 RT. FABRICATED NEW FLOOR PANEL IAW EO A300-5320-16407-C. THIS CLEARS D396887.SDR 2009FA0000584Panel · corrodedOUT OF LIMITS CORROSION ON FWD PIT CENTER DECK PANEL BS 500- 500D. PANEL IS LISTED STRUCTURE IAW SRM 51-00-04.SDR 2009FA0000582Panel · corrodedOUT OF LIMITS CORROSION ON FWD PIT DECK PANEL AT BS 428-500. PANEL IS LISTED PRIMARY STRUCTURE IAW SRM 51-00-04.SDR ASAA0956037Floor Panel · damagedACB NR 2 FLOOR PANEL HAS A DEEP GOUGE/DENT AT AFT END LBL 10. REPAIRED IAW EA.SDR 2009FA0000576Floor Panel · corrodedOUT OF LIMITS CORROSION ON AFT PIT CTR FLOOR PANEL TOP SURFACE. PANEL IS LISTED PRIMARY STRUCTURE IAW SRM 51-00-04.SDR FDEA200906242262Floor Panel · delaminatedFLOOR PANEL FOUND DELAMINATED. REPLACED FLOOR PANEL. FABRICATED IAW PL 141N5369-14 SHT 6, 15 & 28 OF 32 AND DRAWING (PG 32 & 33.1). REPAIR IS CLASSIFIED AS MINOR AS PER GMM 6-2100 CRITERIA.SDR FDEA200906242261Floor Panel · delaminatedFLOOR PANEL (PN 141N5369-15) FOUND DELAMINATED. REPLACED FLOOR PANEL. NEW FLOOR PANEL FABRICATED IAW PL 141N5369-15 (SHT 6, 7, 16 & 28 OF 32) AND DWG (SHT 3). FABRICATED FLOOR PANEL PART MARKED AS FX 141N5369-15 IAW GMM 7-0-1001. REPAIR IS CLASSIFIED AS SDR FDEA200906242260Floor Panel · delaminatedFLOOR PANEL (PN 141N5369-12) FOUND DELAMINATED. REPLACE FLOOR PANEL. NEW FLOOR PANEL FABRICATED IAW PL 141N5369-12 (SHT 6, 15 & 28 OF 32) AND DWG (PG 28, 29.1, 46 & 49). FABRICATED FLOOR PANEL PART MARK AS FX-141N5369-12 IAW GMM 7-0-1001. REPAIR IS CLASSSDR ASAA0995998Floor Panel · dentedAFT CARGO BAY NR 3 FLOOR PANEL IS DENTED AND DAMAGED. REMOVED, FABRICATED AND INSTALLED NR 3 FLOOR PANEL.SDR ASAA0995997Floor Panel · corrodedFLOOR PANEL CORRODED AFT CARGO BAY. FABRICATED AND REPLACED FLOOR PANEL.SDR ASAA0995994Floor Panel · dentedFWD CARGO BAY NR5 FLOOR PANEL HAS NUMEROUS DENTS. FABRICATED FWD CARGO BAY NR 5 FLOOR PANEL.SDR IPXA09156523Floor Panel · misrepairedINSPECTION TYPE:4C MAIN CABIN FLOORBOARD 252BN PREVIOUS REPAIR NOT PER A300 SRM. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156522Floor Panel · misrepairedINSPECTION TYPE:4C MAIN CARGO COMPARTMENT FLOORBOARD 252UJ PREVIOUS REPAIR NOT PER SRM. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09156521Floor Panel · misrepairedINSPECTION TYPE:4C BULK PIT FLOORBOARD 161HF PREVIOUS REPAIR NOT IN ACCORDANCE WITH SRM. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX D.SDR IPXA09156520Floor Panel · misrepairedINSPECTION TYPE:4C MAIN CARGO COMPARTMENT FLOORBOARD 252EN PREVIOUS REPAIR NOT IN ACCORDANCE WITH A300 SRM. FABBED FLOOR PANEL IAW UPS EO A300-5320-16407-C, APPX B.SDR IPXA09556526Floor Panel · corrodedINSPECTION TYPE:C2 MAIN CARGO DECK - FLOOR PANEL SUPPORT TO BS 1016, LBL 25 TO LBL 45 HAS CORROSION. FABRICATED PART IAW BOEING DRAWING 144N5005, INSTALLED FLOOR PANEL SUPPORT IAW SRM 51-40-02-0G.SDR IPXA09156457Floor Panel · damagedINSPECTION TYPE:4/C VALIDATION SURVEY BULK CARGO PIT FLOOR PANEL 161HF, HAS PREVIOUS REPAIR THAT WAS NOT SIGNED OFF TO A EO THAT CONTAINS SPECIFIC REPAIR PROCEDURES. FABBED FLOOR PANEL 161HF IAW IPXA EO A300-5320-16407-C, APPX D.SDR IPXA09156454Floor Panel · damagedINSPECTION TYPE:4/C VALIDATION SURVEY BULK CARGO PIT FLOOR PANEL 161GF HAS PREVIOUS REPAIR THAT SIGNED OFF TO AN EO THAT CONTAINS NO SPECIFIC REPAIR PROCEDURES. FABBED FLOOR PANEL 161GF IAW IPXA EO A300-5320-16407-C, APPX D.SDR IPXA09156453Floor Panel · damagedINSPECTION TYPE:4/C MAIN CABIN FLOOR PANEL 241LN HAS SEVERAL PUNCTURES. FABBED FLOOR PANEL 241LN IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09156452Floor Panel · damagedINSPECTION TYPE:4/C VALIDATION SURVEY BULK CARGO PIT FLOOR PANEL162HF HAS PREVIOUS REPAIR THAT WAS SIGNED OFF TO AN EO THAT CONTAINS NO SPECIFIC REPAIR PROCEDURES. FABBED FLOOR PANEL 162HF IAW IPXA EO A300-5320-16407-C, APPX D.SDR IPXA09156451Floor Panel · damagedINSPECTION TYPE:4/C MAIN CABIN FLOOR PANEL 232SG, HAS SEVERAL PUNCTURES. FABBED FLOOR PANEL 232SG IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09156449Floor Panel · damagedINSPECTION TYPE:4/C MAIN CABIN FLOOR PANEL 232EF, HAS HOLES ON THE FIELD REPAIR. FABBED FLOOR PANEL 232EF IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09156448Floor Panel · misrepairedINSPECTION TYPE:4/C VALIDATION SURVEY BULK CARGO PIT FLOOR PANEL 161JF HAS PREVIOUS REPAIR THAT IS NOT COVERED BY APPROVED STRUCTURAL REPAIR PROCEDURE. FABBED FLOOR PANEL 161JF IAW IPXA EO A300-5320-1647-C, APPX D.SDR IPXA09156447Floor Panel · damagedINSPECTION TYPE:4/C MAIN CABIN FLOOR PANEL 242 LJ FIELD REPAIR HAS HOLES. FABBED FLOOR PANEL IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09656409Floor Panel · crackedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND CRACK 2 INCH LONG AT STA 975 TO STA 1043 LBL 33 TO LBL 55. FLOOR PANEL FABRICATED AS PER EO B767-5320-9693-F AND INSTALLED AS PER AMM 53-01-01.SDR IPXA09656399Floor Panel · puncturedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND PUNCTURED AT STA 650 RBL 6. FLOOR PANEL REPAIR AS PER SRM 53-00-50-2R FIG 201, REV 44.SDR IPXA09656398Floor Panel · puncturedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND PUNCTURED AT STA 1452 RBL 48. FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R FIG 201 REV 44.SDR IPXA09656397Floor Panel · puncturedINSPECTION TYPE:7C MCD FLOOR PANEL FOUND PUNCTURED AT STA 1580 LBL 28. FLOOR PANEL REPAIRED AS PER SRM 53-00-50-2R FIG 201 REV 44.SDR ASAA0995975Floor Panel · dentedAFT CARGO BAY NR 3 FLOOR PANEL IS DENTED AND DAMAGED. REMOVED, FABRICATED AND INSTALLED NR 3 FLOOR PANEL.SDR ASAA0995956Floor Panel · gougedFWD CARGO FLOOR PANEL NR 3 PUNCTURED AND GOUGED. FABRICATED NEW FLOOR PANEL.SDR ASAA0995952Floor Panel · damagedFWD CARGO BAY FLOOR PANEL NR 5 P/N 453A1610 84. FABRICATED NEW PANEL.SDR ASAA0995951Floor Panel · corrodedCORROSION AFT CARGO BAY FLOOR PANEL NR 5 HAS CORROSION. REPAIRED AND REPLACED NR 5 FLOOR PANEL.SDR IPXA09156461Floor Panel · damagedINSPECTION TYPE:4/C FLOOR PANEL 132DE IS MISSING INSERTS AND DELAMINATED. FABBED FLOOR PANEL 132DE IAW IPXA EO A300-5320-16407-C, APPX C.SDR IPXA09156456Floor Panel · damagedINSPECTION TYPE:4/C VALIDATION SURVEY FWD CARGO PIT FLOOR PANEL 132PG HAS PREVIOUS REPAIR INSTALLED THAT IS NOT COVERED BY AN APPROVED SRM. FABBED FLOOR PANEL 132PG IAW IPXA EO A300-5320-16407-C, APPX C.SDR IPXA09156455Floor Panel · damagedINSPECTION TYPE:4/C FLOOR PANEL 132AH IS MISSING INSERTS AND DELAMINATED. FABBED FLOOR PANEL 132AH IAW IPXA EO A300-5320-16407-C, APPX C.SDR IPXA09156450Floor Panel · misrepairedINSPECTION TYPE:4/C VALIDATION SURVEY PANEL 242 WK CARGO MAIN FLOOR PANEL HAS PREVIOUS REPAIR NOT COVERED BY AN APPROVED SRM. FABBED FLOOR PANEL 242WK IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09656427Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1480 TO STA 1598 LBL 11 TO RBL 11. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09656426Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1197+22 TO STA 1207 LBL 11 TO RBL 11. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.SDR IPXA09656425Floor Panel · damagedINSPECTION TYPE:C MCD FLOOR PANEL FOUND DAMAGED AT STA 1207 TO STA 1344 LBL 11 TO RBL 11. FLOOR PNL FABRICATED AS PER EO B767-5320-9693-F & INSTALLED PER AMM 53-01-01.
Back to JASC 5321