JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA051582Floor Panel · delaminatedFOUND DELAMINATION FS 11. COMPOSITE DOUBLER INSTALLED PER SRM 53-02-00, DEFECT SIZE: 2" BY 5".SDR USAA051583Floor Panel · delaminatedFOUND DELAMINATION FS 23. COMPOSITE DOUBLER INSTALLED PER SRM 53-02-00, DEFECT SIZE: 1" BY 4".SDR USAA051575Floor Panel · corrodedFOUND CORROSION FS 34 Y1456. MODIFIED PART INSTALLED PER TR 53-002-01, DEFECT SIZE: 5" BY 16".SDR ASOA051109Floor Skin · corrodedDURING A C-CHECK, THE RT SIDE PRESSURE FLOOR SKIN, AT FS 515.00, WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE IS SUBMITTING A DAMAGE REPORT TO MFG FOR ISSUANCE OF AN REO TO DETERMINE THE APPROPRIATE C/A. (K)SDR ASOA051112Floor Skin · corrodedDURING C-CHECK, THE PRESSURE FLOOR SKIN OB OF LBL 9, BETWEEN FS 449.85 AND FS 559+2, WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE IS SUBMITTING A DAMAGE REPORT TO MFG FOR ISSUANCE OF AN REO TO DETERMINE THE APPROPRIATE C/A. (K)SDR ASOA051112SFloor Skin · corrodedDURING C-CHECK, THE PRESSURE FLOOR SKIN OB OF LBL 9, BETWEEN FS 449.85 AND FS 559+2, WAS FOUND TO BE CORRODED BEYOND LIMITS. UPON FURTHER INSPECTION OF THE PRESSURE FLOOR SKIN OB OF LBL 9, BETWEEN FS 449.85 AND FS 559+2, MAINTENANCE DETERMINED IT WAS NOT CORRSDR ASOA051109SFloor Skin · corrodedDURING A C-CHECK, THE RT SIDE PRESSURE FLOOR SKIN, AT FS 515.00, WAS FOUND TO BE CORRODED BEYOND LIMITS. AFTER MAINTENANCE BLENDED, ALODINED, AND PRIMED THE RT SIDE PRESSURE FLOOR SKIN, AT FS 515.00, IAW SRM 51-21-11 AND 51-42-06, IT WAS FOUND TO BE WITHIN LISDR ASAA0580542Floor Panel · corrodedC-CHECK, CABIN FLOOR PANEL HAS CORRODED INSTERTS AND IS DELAMINATED AROUND INSTERS. REPLACED FLOOR PANEL. (K)SDR ASAA0580548Floor Panel · delaminatedC-CHECK, CABIN FLOOR PANEL IS DELAMINATED. REPLACED FLOOR PANEL. (K)SDR ASAA0580547Floor Panel · delaminatedC-CHECK, CABIN FLOOR PANEL IS DELAMINATED. REPLACED FLOOR PANEL. (K)SDR ASAA0580546Floor Panel · delaminatedC-CHECK, CABIN FLOOR PANEL IS DELAMINATED. REPLACED FLOOR PANEL. (K)SDR ASAA0580545Floor Panel · corrodedC-CHECK, CABIN FLOOR PANEL HAS CORRODED INSERTS AND IS DELAMINATED AROUND INSERTS. REPLACED FLOOR PANEL. (K)SDR ASAA0580544Floor Panel · delaminatedC-CHECK, CABIN FLOOR PANEL IS DELAMINATED. REPLACED FLOOR PANEL. (K)SDR ASAA0580543Floor Panel · delaminatedC-CHECK, CABIN FLOOR PANEL IS DELAMINATED. REPLACED FLOOR PANEL. (K)SDR ASAA0850542Floor Panel · corrodedC-CHECK, CABIN FLOOR PANEL HAS CORRODED INSERTS AND DELAMINATED AROUND INSERTS. REPLACED FLOOR PANEL. (K)SDR F3LA200500046Floor Panel · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION ON FLOOR PANEL 261FF. REMOVED SURFACE CORROSION FROM FLOOR PANEL 261FF. REPAIRED FLOOR PANEL PER SRM 53-02-00 FIG 202.SDR AWXA200501488Floor Panel · corrodedSAL - DURING BC4 CHECK DISCOVERED LEVEL TWO GALVANIC CORROSION ON 131HF FWD CARGO FLOOR PANEL UPPER SURFACE. CORROSION WAS FOUND OUT OF LIMITS IAW AIRBUS 320 SRM 53-02-00 TABLE 105. REPLACEMENT PANEL FABRICATED IAW IRM 9701 REV F PAR 8. INSTALLED REPAIR PARSDR USAA051421Floorboard · crackedAT 41 INCHES FROM END, 64 INCHES FROM OPP END, 4 INCHES FROM EDGE, 15 INCHES FROM OPP EDGE CRACKED. FILLED AND INSTALLED PRECURED DOUBLER IAW SRM 53-02-00 FIG 203. DEFECT SIZE: 5 INCHES.SDR SWAA053676Web · crackedDURING SCHEDULED D CHECK, FOUND COCKPIT FLOOR WEB CRACKED BETWEEN BS 188 TO BS 196.5, LBL 29, WL 207. REPAIRED FLOOR WEB PER SRM.SDR SWAA053672Web · crackedDURING SCHEDULED D CHECK, FOUND COCKPIT FLOOR WEB CRACKED BETWEEN BS 188 TO BS 196.5, RBL 29, WL 207. REPAIRED FLOOR WEB PER SRM.SDR DHL2005803502Floor Panel · corrodedITEM REF. NR. 033228: MAIN CARGO COMPT INTERIOR FLOOR PANEL SUPPORT CORRODED, STA 1726.000 RBL 30. REMOVED CORROSION IAW SRM 51-1-8 PG. 17-18. MEASURED THICKNESS 0.090". BLEND OUT 0.024", REMAINING MATERIAL 0.066". FOUND OUT OF ALLOWABLE LIMITS IAW SRM 53-2-0 SDR 05FDEA03833Floor Panel · corrodedCENTER LOWER CARGO COMPT FLOOR PNL 183ZF HAS BROKE AND CORRODED INSERTS STA 1781 TO 1821 RBL 30 TO37. REMOVED AND REPLACED INSERTS IAW FEDEX DWG SRA 25-005 REV E.SDR DHL2005803500Floor Panel · corrodedITEM REF. NR. 033352: MAIN CARGO COMPT. FLOOR PANEL CORRODED, STA 0440.000 LBL 56. REMOVED CORROSION FROM FLOOR PANEL STA 1440.000 LBL 56" IAW SRM 51-1-8 PG. 17-18. FOUND OUT OF LIMITS IAW SRM 53-2-0 PG. 2P. CUT OUT DAMAGED SECTION AND FABRICATED DOUBLER (7075SDR DHL2005803501Floor Panel · corrodedITEM REF NR 033351: MAIN CARGO COMPT. FLOOR PANEL CORRODED, STA 1360.000 LBL 56". REMOVED CORROSION IAW SRM 51-1-8 PG. 17-18 FLOOR PANEL THICKNESS 0.071". BLEND OUT 0.035", REMAINING MATERIAL 0.036". FOUND OUT OF ALLOWABLE LIMITS IAW SRM 53-2-0 PG. 2P. TRIMMEDSDR AWXA200501438Floor Panel · corrodedSAL - DURING BC4 CHECK DISCOVERED GALVANIC CORROSION ON 131CG FORWARD CARGO COMPARTMENT FLOOR PANEL UPPER SURFACE FROM FS 28 TO FS 31 AND FROM Y765 TO -Y765. MAINTENANCE REMOVED AND REPLACED CARGO COMPARTMENT FLOOR PANEL WITH NEW PANEL IAW IRM 9701 REV F.SDR 2005FA0001520Floorboard · crackedFOUND FLOORBOARD SKIN ABOVE THE LT AND RT GEAR BOXES, CRACKED AT THE INSPECTION HOLES. CRACKS RAN FROM THE EDGE OF THE HOLE TO THE SCREW HOLE FOR THE INSPECTION PLATE. INSTALLED A REINFORCEMENT UNDER THE DOUBLER AND STOP DRILLED THE CRACKS. (K)SDR 05FDEA03586Floor Panel · crackedFOUND COCKPIT FLOOR SECTION STA 304 BY 13 CRACK ON MEMBRANE 2'' LONG RIF SRM 53-11-01 ITEM 1. REPAIRED CRACK ON MEMBRANE RIF SRM 53-11-01 ITEM 1 STA 304 BY 13.SDR 05FDEA03585Floor Panel · crackedCOCKPIT FLOOR STRUCTURE FOUND 1 EA CRACK 2 INCHES LONG ON MEMBRANE STA 304 X-27 RT SIDE. REPAIRED CRACK ON MEMBRANE RIF 53-11-01 STA 304 X-27 RT SIDE.SDR 05FDEA03584Floor Panel · crackedCOCKPIT FLOOR STRUCTURE FOUND 1 EA CRACK 2 INCHES LONG ON MEMBRANE STA 304 X-12 RT SIDE. REPAIRED CRACK ON MEMBRANE STA 304 X-12 RT SIDE RIF SRM53-11-01, ITEM 1.SDR 05FDEA03582Floor Panel · crackedCOCKPIT FLOOR SECTION STA 313 CRACK ON MEMBRANE 1 INCH LONG RIF SRM 53-11-01, ITEM 1. REPAIRED MEMBRANE AT STA 313 RIF SRM53-11-01 FIG 4 SHT 2 VOL 1.SDR 05FDEA03540Floor Panel · crackedINTERNAL COCKPIT FLOOR AREA FOUND 1 EA CRACK 2 INCHES LONG ON TEE ANGLE AT STA 275 X -45, RT. PERFORMED INSPECTION IAW NDT SPM 06, NO CRACK FOUND ON FLOOR AREA TEE ANGLE STA 275 X-45 ONLY PENCILE MARK.SDR 05FDEA03517Floor Panel · crackedINTERNAL LWR COCKPIT AREA FOUND 2 CRACKS ON SAME MEMBRANE 1ST .50" LONG; 2ND IS 2" LONG; BETWEEN STA 304 TO STA 318; AND BETWEEN X12 TO X13 LT SIDE. REPAIRED MEMBRANE IAW SRM 53-00-01 VOL 1 FIG 10 SHT 4 AND SRM 51-35-01. FABRICATED PARTS IAW DETAIL PARTS TRASDR SWAA053363Floor Panel · corrodedDURING SCHEDULED D CHECK, FOUND COCKPIT FLOOR WEB CORRODED AT BS 267, RBL 12. REPAIRED FLOOR WEB PER SRM.SDR SWAA053345Floor Panel · corrodedDURING SCHEDULED D CHECK, FOUND COCKPIT FLOOR WEB CORRODED AT BS 259 TO BS 270, LBL 11 AND RBL 11. WL 208. REPAIRED WEB PER SRM.SDR ASAA0570100Floor Panel · damagedPAE: DURING IS CHECK FOUND FLOOR PANEL DAMAGED. REPAIRED IAW SRM. (K)SDR ASAA0570098Floor Panel · damagedPAE - DURING SI CHECK, FOUND FORWARD CARGO BAY AFT FLOOR PANEL FASTENER PULLING THROUGH TEMP REPAIR. REPAIRED IAW SRM 53-00-53/51-40-5. (M)SDR GTIA050201Floor Panel · corrodedFTW - FOUND FORWARD ENTRY AREA FLOOR WEB STATION 450-200, LBL 12 INCHES IS CORRODED. REMOVED FORWARD AIRSTAIR SHROUD TO FOM. REMOVED CORROSION AND FOUND MATERIAL IS OUT OF LIMITS. CUT OUT DAMAGE AREA (2 INCHES BY 2 INCHES). FABRICATED REPAIR DOUBLER. TREASDR 2005UALA01172Floor Panel · corrodedFWD CABIN FLOOR RT INNER CORD UNDER FLOOR PANEL IS CORRODED, FROM BS 280 TO 348 WL 208.1 RBL 54. REMOVED AND REPLACED CREASE BEAM AND DRAIN PAN REF SRM 51-40-02.SDR 2005FA0001515Floor Panel · corrodedDURING A PRE-BUY INSPECTION, THE LONCOIN RUBBER MATS WERE PULLED UP FROM THE COCKPIT FLOORS. UNDER THE PILOTS SIDE OF THE MATS, MAJOR CORROSION ACCUMULATION WAS DISCOVERED. THESE MATS WERE STILL DAMP UNDERNEATH WHICH SHOWED WHY THIS CORROSION EXISTED. SUSPESDR AWXA200501305Floor Panel · crackedMCN - DURING C16 CHECK DISCOVERED FLOOR WEB CRACKED AT BS 195 BL 31R AND WL 207. MAINTENANCE REMOVED FLOOR WEB AT BS 195, BL 31R AND WL 207 IAW BOEING 737-300 SRM 51-40-02-0G FIG 8. FABRICATED REPAIR WEB IAW BOEING 737-300 SRM 53-10-51-2R 8 FIG 201. INSTALLSDR AWXA200501304Floor Panel · crackedMCN - DURING C16 CHECK DISCOVERED FLOOR WEB CRACKED, 1.1 INCHES IN LENGTH, AT BS 195 BL 31L AND WL 207. MAINTENANCE REMOVED FLOOR WEB AT BS 195, BL 31L AND WL 207 IAW BOEING 737-300 SRM 51-40-02-0G FIG 8. FABRICATED REPAIR WEB IAW BOEING 737-300 SRM 53-10-51SDR ASOA05863Floor Panel · corrodedDURING A C-CHECK IN MCN, THE PRESSURE FLOOR SKIN AT FS 473.15, LBL 36 WAS FOUND TO BE CORRODED BEYOND LIMITS. (M)SDR 05FDEA03408Floor Panel · corrodedCORROSION ON MAIN CARGO DECK FLOOR PANEL WEB AT BS 1150, RBL 60, WL 208. CUT OUT DAMAGE FLOOR WEB AT BS 1150, RBL 60, WL 208 AND INSTALLED REPAIR DOUBLER PER SRM 51-40-2.SDR ASAA05710087Floor Panel · puncturedDURING C-CHECK FOUND AFT CARGO PIT NR 2 FLOOR PANEL PUNCTURED. REPAIRED IAW SRM. (K)SDR ASAA0570086Floor Panel · puncturedDURING C-CHECK, FOUND FWD CARGO PIT NR 2 FLOOR PANEL PUNCTURED. REPAIRED IAW SRM. (K)SDR ASAA0570085Floor Panel · puncturedDURING C-CHECK FOUND AFT CARGO PIT NR 3 FLOOR PANEL PUNCTURED. REPAIRED IAW SRM. (K)SDR ASAA0570084Floor Panel · dentedDURING C-CHECK FOUND AFT CARGO PIT NR 1 FLOOR PANEL DENTED AND PUNCTURED. REPAIRED IAW SRM. (K)SDR UPS05545673Floor Panel · corrodedINSPECTION TYPE:C4 CONTROL CABIN FLOOR SURFACE CORRODED BS282 LBL 28 WL 200. REPAIRED PER SRM 51-70-13-00.SDR EIA2005207Floor Panel · crackedFOUND BS 2198 LBL 99 FLOOR WEB CRACKED. REPAIRED FLOOR WEB PER SRM 51-40-02, FIG 1.SDR ASAA0570073Floor Panel · puncturedPAE: DURING C-CHECK, FOUND FWD CARGO NR 3 FLOOR PANEL PUNCTURED. REPAIRED IAW SRM. (K)
Back to JASC 5321