As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FTW - FOUND FORWARD ENTRY AREA FLOOR WEB STATION 450-200, LBL 12 INCHES IS CORRODED. REMOVED FORWARD AIRSTAIR SHROUD TO FOM. REMOVED CORROSION AND FOUND MATERIAL IS OUT OF LIMITS. CUT OUT DAMAGE AREA (2 INCHES BY 2 INCHES). FABRICATED REPAIR DOUBLER. TREATED AND PRIMED. INSTALLED REPAIR DOUBLER AND REINSTALLED AIRSTAIR SHROUD. (M)