JASC 5321

Service difficulty reports · 49,402

Reports filed under 5321 · Fuselage Floor Panel, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5321'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR RRXA002484Floorboard · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES ON THE FLOOR PANEL TO FLOORBEAM ATTACH FASTENER AT STA 1240 - 1460 ROW 12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IMay 16, 2000 · N995CF · Doug DC862SDR RRXA002483Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 660 - 1000 ROW 7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862SDR RRXA002482Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 660 - 1000 ROW 6 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 16, 2000 · N995CF · Doug DC862SDR RRXA002478Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 4 FLOOR PANEL AT STA 1000 - 1460 ROW 7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047May 16, 2000 · N995CF · Doug DC862SDR RRXA002477Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 4 FLOOR PANEL AT STA 1000 - 1240 ROW 1 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-May 16, 2000 · N995CF · Doug DC862SDR RRXA002476Floorboard · damagedDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 320 - 600, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-04May 16, 2000 · N995CF · Doug DC862SDR RRXA002458Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT STA 235 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862SDR RRXA002457Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT STA 235 - 230, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862SDR RRXA002456Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOOR PLANK AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862SDR RRXA002455Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT STA 520 - 580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862SDR RRXA002454Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PANEL AT STA 225 - 420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862SDR RRXA002453Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PANEL AT STA 800 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVMay 16, 2000 · N995CF · Doug DC862SDR RRXA002451Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT FS 225, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3May 16, 2000 · N995CF · Doug DC862SDR RRXA002449Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES ON THE FLOOR PLANK AT STA 320 - 600 LT ROW 2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITMay 16, 2000 · N995CF · Doug DC862SDR RRXA002447Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 320 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862SDR RRXA002445Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 660 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862SDR RRXA002444Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE UPPER AND LOWER SIDE AT STA 660 - 880 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00May 16, 2000 · N995CF · Doug DC862SDR RRXA002443Floorboard · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOOR PANEL ON UNDERSIDE AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DMay 16, 2000 · N995CF · Doug DC862SDR RRXA002442Floorboard · damagedDURING A MAINTENANCE VISIT FOUND LONGATED HOLES TO THE FLOOR PANEL AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DAMay 16, 2000 · N995CF · Doug DC862SDR RRXA002441Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE CABIN FLOOR PANEL AT STA 255 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8May 16, 2000 · N995CF · Doug DC862SDR RRXA002440Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE CABIN FLOOR PANEL AT STA 215 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WMay 16, 2000 · N995CF · Doug DC862SDR RRXA002367Floorboard · tool damageDURING A MAINTENANCE VISIT FOUND TOOLING MARKS GOUGED ON FLOOR PANEL AT STA 660 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 AND EO NR 00-047 WMay 16, 2000 · N995CF · Doug DC862SDR RRXA002353Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND ELONGATED HOLES IN THE CABIN FLOOR PLANK AT STA 1000 TO 1320 ROW 5 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED HOLES AND BLENDED IAMay 16, 2000 · N995CF · Doug DC862SDR RRXA002296Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE FLOOR PANEL AT STA 1000 - 1460 ROW 3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8110May 16, 2000 · N995CF · Doug DC862SDR RRXA002295Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR PANEL AT STA 1000 - 1240 ROW 12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 4-2-0May 16, 2000 · N995CF · Doug DC862SDR RRXA002294Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND LONGATED HOLES IN THE FLOOR PANEL AT STA 1000 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 DMay 16, 2000 · N995CF · Doug DC862SDR 00FDEA00338Floorboard · crackedDURING ROUTINE INSPECTION, CRACKS FOUND IN FLOOR WEB FWD OF BS 1183 BULKHEAD BL 0 TO LBL 45. REMOVED AND REPLACED WEB PER IAW SRM 51-20-1 AND SRM 51-30-2.May 16, 2000 · N480FE · Boeing 727227SDR 00FDEA00337Floorboard · crackedDURING ROUTINE INSPECTION, CRACKS FOUND IN FLOOR WEB FWD BS 1183 BULKHEAD FROM BL 0 TO RBL 45. REMOVED, FABRICATED AND INSTALLED WEB IAW SRM 51-20-1 & 51-30-2.May 16, 2000 · N480FE · Boeing 727227SDR RRXA002650Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 1000 - 1040 RT ROW 8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NMay 15, 2000 · N995CF · Doug DC862SDR RRXA002641Floorboard · damagedDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED AND ELONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 1000 - 1320 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EOMay 15, 2000 · N995CF · Doug DC862SDR RRXA002490Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOOR PLANK AT FS 1460 - 1580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEMay 15, 2000 · N995CF · Doug DC862SDR RRXA002446Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND LONGATED HOLES IN THE FLOOR PANEL AT STA 420 - 620, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPMay 15, 2000 · N995CF · Doug DC862SDR RRXA002368Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 1460 - 1580 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 15, 2000 · N995CF · Doug DC862SDR RRXA002366Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE FLOOR PANEL AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 81May 15, 2000 · N995CF · Doug DC862SDR RRXA002365Floorboard · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE IN 3 PLACES TO THE FLOOR PANEL AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 AND EO NR 0May 15, 2000 · N995CF · Doug DC862SDR RRXA002364Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE FLOOR PANEL ROW 7 AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED AND BLENDED HOLES IAW EO NR 00-047 WITH APPROVED 8May 15, 2000 · N995CF · Doug DC862SDR RRXA002363Floorboard · damagedDURING A MAINTENANCE VISIT FOUND DAMAGE IN 3 PLACES TO THE FLOOR PANEL ROW 7 AT STA 1580 - 1600 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED DAMAGE IAW DC-8 SRM 53-2-0 AND EO NR 00-047 WITMay 15, 2000 · N995CF · Doug DC862SDR RRXA002362Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 1460 - 1480 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED AND BLENDED HOLES IAW EO NR 00-047 WITH APMay 15, 2000 · N995CF · Doug DC862SDR RRXA002361Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 1460 TO 1500 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED HOLES IAW EO NR 00-047 WITH APPROVED 8110May 15, 2000 · N995CF · Doug DC862SDR CALA0000680Floorboard · corrodedINSPECTION FOUND AFT CARGO PIT REMOVABLE BULKHEAD FLOOR TRANSITION PANEL CORRODED ON TOP SURFACE AT STA 1320. THE PANEL WAS REMOVED AND REPLACED IAW SRM 51-30-2.May 15, 2000 · N72830 · Doug DC982SDR L1GA200000169Floorboard · crackedCRACK ON CABIN FLOOR PANEL L/E STATION 237 O/B OF X44L.May 10, 2000 · N27509 · Doug DC932SDR L1GA200000098Floorboard · crackedCABIN FLOOR PANEL I/B EDGE CRACKED AT STATION 351 X24L TO X44L.May 10, 2000 · N27509 · Doug DC932SDR L1GA200000096Floorboard · brokenOUTBOARD CABIN FLOOR PANEL AT STATION 756 X44L TO X54L BROKEN.May 10, 2000 · N27509 · Doug DC932SDR L1GA200000094Floorboard · puncturedA .875 INCH DIAMETER PUNCTURE AND CRACK WAS FOUND IN THE FLOOR PANEL AT FS 389 LBL 48.May 10, 2000 · N27509 · Doug DC932SDR L1GA200000093Floorboard · crackedFLOORBOARD PANEL NUMBER 65 WAS FOUND TO HAVE A PUNCTURE AND CRACK.May 10, 2000 · N27509 · Doug DC932SDR L1GA200000092Floorboard · puncturedA 1.5 INCH PUNCTURE WAS FOUND IN THE FLOORBOARD AT FS 455 RBL 12.May 10, 2000 · N27509 · Doug DC932SDR L1GA200000091Floorboard · crackedA 3 INCH SECTION OF THE FOWARD INBOARD CORNER OF PANEL NUMBER 4221A WAS CRACKED AND TORN AT STATION 133BL 30 LEFT.May 10, 2000 · N27509 · Doug DC932SDR L1GA200000090Floorboard · corrodedCORROSION WITH A PUNCTURE WAS FOUND ON THE CABIN FLOOR PANEL NUMBER 26 BETWEEN X54 LEFT AT STATION 275.May 10, 2000 · N27509 · Doug DC932SDR L1GA200000089Floorboard · crackedA CRACK WAS FOUND ON THE CABIN FLOOR PANEL NUMBER 38 AT STATION 389 X44 LEFT TO 54 LEFT.May 10, 2000 · N27509 · Doug DC932SDR L1GA200000080Floorboard · crackedTHE RIGHT OUTBOARD CABIN FLOORBOARD PANEL AFT END WAS CRACKED AND DEFORMED.May 10, 2000 · N27509 · Doug DC932
Back to JASC 5321