JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA002351Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PLANK NR 2 STA 233 TO 315, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 5-16SDR RRXA002293Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE MAIN CABIN FLOOR PLANK ROW 8 AT STA 1240 - 1460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APSDR QXEA0001570Floorboard · damagedYYC- FLOOR PANEL 25BB HAS ONE INSERT MISSING AND ONE CORRODED WITH SEAL WORN. REPAIRED IAW FOKKER SRM 51-70-03 PAGE 23.SDR RRXA003452Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBOARD PLANKS NEAR LAVATORY AT FS 41-57, X-31 TO -44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SSDR QXEA0001592Floorboard · corrodedYYC- FLANGES FOR CENTER FLOORBOARDS HAVE VARIOUS SPOTS OF FRETTING CORROSION FROM FRONT ENTRANCE TO PARTIAL BULKHEAD. REPAIRED IAW FOKKER SRM 53-1-01.SDR RRXA002639Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 500 - 660 ROW 1 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-0SDR RRXA002450Floorboard · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED END TO THE FLOOR PLANK AT STA 800 - 1020, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DASDR RRXA002448Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 800 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH ASDR RRXA002635Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK RT UPPER SKIN AT STA 1460 - 1606, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-SDR RRXA002485Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 3 FLOOR PLANK AT STA 800 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH ASDR RRXA002452Floorboard · crackedDURING A MAINTENANCE VISIT FOUND HOLES AND CRACKS TO THE FLOORBOARD AT FS 860 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DSDR RRXA002352Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE FLOOR PLANK AT STA 1240 TO 1460 ROW 10 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8SDR RRXA002301Floorboard · damagedDURING A MAINTENANCE VISIT FOUND HOLES ELONGATED AND CHAFED UNDERSIDE ON NR 5 FLOOR PANEL 320 - 620 ROW 4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH ASDR RRXA002300Floorboard · crackedDURING A MAINTENANCE VISIT FOUND CRACKED OUT FASTENER HOLES TO THE NR 7 FLOOR PANEL 320 - 620 FLOORBEAM ATTACH POINT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK IAW EO NR 00-047 WSDR MALA000400Floorboard · damagedFOUND DURING C-CHECK FLOORBOARD 121BZ HAS COMPOSITE DAMAGE. MAINTENANCE FABRICATED FLOOR PANEL 121BZ PER ORIGINAL IAW SAAB STATEMENT 72LCS0689.SDR RRXA003448Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LWR SIDE OF FLOOR AT STA 25-55 AND LBL 51, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-3-0.SDR AT0000315Floorboard · corrodedFOUND CABIN FLOOR CORRODED AND CRACKED. REPAIRED SKIN, FABRICATED NEW HAT CHANNELS AND INSTALLED IAW DC9 SRM 53-21-01, 51-10-4, 51-10-3, 51-10-2, 51-30-2, 51-70-1.SDR TWAA0008305Floorboard · crackedDURING OP16 FOUND A CRACK IN THE FLOOR MEMBRANE AT FS 614 RBL 56. REMOVED MEMBRANE FROM STATION 598 - 658 REF INTER-SHOP WORK TICKET 858855 FOR NEW MEMBRANE FABRICATION, INSTALLED MEMBRANE ON THE AIRCRAFT PER MD SRM 51-30-02 RIVET INSTALLATION AND 51-30-0 BOLSDR AT0000312Floorboard · delaminatedFOUND CABIN ENTRY FLOOR PANEL NR 4691 AT BS 160 - 200 DELAMINATED AND SPONGY. REMOVED FLOOR PANEL, FABRICATED NEW FLOOR PANEL, INSTALLED NEW FLOOR PANEL IAW TIMCO SERVICE ORDER 151057-49500.SDR AT0000307Floorboard · corrodedFOUND CABIN FLOOR PANEL HAS CORROSION AT PANEL 66. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC9 SRM 53-21 FIGURE 3.SDR L1GA200000165Floorboard · corrodedLEVEL 2 CORROSION FLOOR PNL BELOW PILOT''S YOKE.SDR L1GA200000135Floorboard · crackedCRACK SUB FLOOR CAPTAIN''S O/B SEAT TRACK.SDR L1GA200000134Floorboard · corrodedLEVEL 2 CORROSION SUB FLOOR AFT END OF CAPTAIN''S I/B SEAT TRACK.SDR L1GA200000160Floorboard · corrodedCORRODED AREA AT FS 579 - 680 BL 44 LEFT FLOOR PANEL.SDR L1GA200000159Floorboard · corrodedCORRODED AREA AT RIGHT AFT LAV ON THE FLOOR PANEL SKIN. FABBED NEW FLOOR.SDR L1GA200000155Floorboard · corrodedCORRODED AREA LOCATED ON THE RIGHT GALLEY FLOOR AREA.SDR L1GA200000133Floorboard · corrodedLEVEL 2 CORROSION FLOOR PNL FS 120 - 218.SDR RRXQA002634Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE FLOOR PANEL AT STA 1000 - 1240 ROW 4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDSDR RRXA002649Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN PLANK CHANNEL ON THE NR 4 FLOOR PANEL AT STA 1000 - 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-0SDR RRXA002648Floorboard · damagedDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE NR 3 FLOOR PANEL AT STA 320 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WISDR RRXA002647Floorboard · damagedDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND ELONGATED HOLES TO THE FLOOR PLANK AT STA 800 TO 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-SDR RRXA002645Floorboard · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED ATTACH POINT HOLES ON THE FLOORBEAM AT NR 1 FLOOR PLANK FS 420 TO 600, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 0SDR RRXA002644Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND LONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 1000 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NRSDR RRXA002643Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 320 - 620, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WISDR RRXA002642Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 1000 - 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH SDR RRXA002640Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 230 - 500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APSDR RRXA002638Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND LONGATED HOLES TO THE FLOOR PANEL AT STA 1000 - 1460 ROW 9 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-0SDR RRXA002637Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 600 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APSDR RRXA002636Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 1000 - 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH SDR RRXA002633Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL NR 4 AT STA 235 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WISDR RRXA002632Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 660 - 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WSDR RRXA002631Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES ON THE FLOOR PANEL AT STA 860 - 1000 ROW 9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 SDR RRXA002494Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 660 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVESDR RRXA002493Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 1240 - 1460 ROW 6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITHSDR RRXA002492Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 3 FLOOR PLANK AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APSDR RRXA002491Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND ELONGATED ATTACH FASTENER HOLES TO THE FLOOR PLANK TO FLOORBEAM ON NR 2 FLOOR PANEL AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. SDR RRXA002489Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOOR PLANKS AT FS 860 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVESDR RRXA002488Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 600 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVESDR RRXA002487Floorboard · gougedDURING A MAINTENANCE VISIT FOUND DENTS AND GOUGES TO THE NR 2 FLOOR PLANK CHANNEL AT STA 1000 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH ASDR RRXA002486Floorboard · gougedDURING A MAINTENANCE VISIT FOUND DENTS AND GOUGES TO THE CENTER CHANNEL ON THE NR 2 FLOOR PLANK AT STA 800 - 1000 ROW 5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW
Back to JASC 5321