JASC 5330
Service difficulty reports · 79,365
Reports filed under 5330 · Fuselage Main, Plate/Skin, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5330' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5330' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA116305Skin · crackedDURING SCHEDULED 26Y CHECK, FOUND SKIN CRACKED AT BS 927+16, STR 25R. REPAIRED SKIN IAW EA.SDR SWAA116299Skin · crackedDURING SCHEDULED 24Y CHECK, FOUND SKIN CRACKED AT BS 294.5+8, STR 17R. REPAIRED SKIN IAW EA.SDR UHLA2011090400309Doubler · corrodedLEVEL 2 CORROSION ON DOUBLER AROUND WASTE SERVICE DOOR BOX. REMOVED AND REPLACED DOUBLER IAW EMB 170 SRM 51-41-02.SDR AALA20110904DWH01Skin · damagedAIRCRAFT WAS DAMAGED BETWEEN STATIONS 1640 AND 1661 BELOW STRINGER 20 RIGHT. DAMAGED SKIN COMPLETELY TRIMMED OUT AND A LAP SKIN DOUBLER INSTALLED OVER TRIMMED OUT SECTION PER 757-200 SRM 53-00-01 FIGURE 201. REPAIRED PER 757 SRM 53-00-01 FIG 201 AND EA B757-SDR USAA2011090600019Skin · crackedRON CHECK - CRACK ON RIGHT SIDE OF FUSELAGE SKIN ABOVE WINDOW NR 13 FROM FRONT ABOVE S10R SKIN 16 INCHES FORWARD OF BS 540. REPAIRED FUSELAGE SKIN AT BS 540, S10R IAW B737 SRM 53-00-01 REPAIR 31.SDR FDEA201109043660Skin · dentedFUSELAGE LEFT SKIN FOUND WITH DENT FWD OF ALTERNATE STATIC PORT AT STA 791.750 BETWEEN S37 AND S38. FUSELAGE LT SKIN AT STA 791.750 BETWEEN S37 AND S38 DENT MEASURED D=0.40", W=2.5", APPROX 6.8" FORWARD OF ALTERNATE STATIC PORT FOUND WITHIN LIMIT IAW SRM 53-00SDR DALA12015770875Skin · dentedRT FUSELAGE SKIN IS DENTED BETWEEN STA 239, 6 INCHES BELOW CUSP LINE. DENT MEASURES 1"X 8"X.025" DEEP. EDDY CURRENT DENT NO CRACKS FOUND. PSDR ASAA11410385Skin · crackedR2 DOOR CUTOUT LOWER FWD CORNER EXTERNAL SKIN CRACKED. REPAIRED R2 DOOR CUTOUT LOWER EXTERNAL SKIN & BEAR STRAP IAW B737 400 SRM 53 00 01 FIG 201 REPAIR 32 DETAIL V.SDR FDEA201109033656Skin · misrepairedEXTERNAL REPAIR DOUBLER LOCATED AT LOWER RT SIDE FUSELAGE SKIN BETWEEN FRAMES 30 TO 31 AND BETWEEN STRINGERS 52 RT TO 55 AT TOILET SERVICING ACCESS HAS INCORRECT RIVETS SIZE INSTALLED IN OUTER ROWS.SDR FDEA201109033645Skin · corrodedLWR FUSELAGE HAS CORROSION ON SKIN RUNNING UNDER RAIN DIVERTER FOR POTABLE WATER SERVICE AT BS 1661.SDR QXEA2011090600806Skin · corrodedFWD BAG DOOR CUTOUT BOTTOM EDGE OF CUTOUT HAS CORROSION. REMOVED CORROSION FROM EDGE CHANNEL IAW SRM 51-21-00-00-01, FOUND TO BE OUT OF LIMITS IAW SRM 53-20-25-00-01. REMOVED DOOR CHANNEL IAW 51-42-05-02-01. MATCH DRILLED NEW EDGE CHANNEL IAW SRM 51-42-05-0SDR QXEA2011090600805Doubler · corrodedINNER ANTENNA SKIN DOUBLER STR 33-32S, FR 71.2-94.8 IS CORRODED. BLENDED CORROSION IAW SRM 51-21-00-00-01. MIN REMAINING THICKNESS .034". RECEIVED AND FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-3891. COMPLIED WITH RD 8/4-53-3891 AND TASK CARD RD 8/4-53-3891.SDR CALA2011090600573Skin · dentedFUSELAGE SKIN DAMAGED AT BS 1080 BETWEEN S22R & S26R. FABRICATED AND INSTALLED REPAIR IN REF TO ECRA 5331-01571.SDR USAA2011090900009Skin · crackedC3 CHECK - CRACK IN FUSELAGE SKIN AT LOWER AFT EDGE OF E & E COOLING DUCT CUTOUT AT BS 360, BL 0. REPAIRED FUSELAGE SKIN AT LOWER AFT EDGE OF E & E COOLING DUCT CUTOUT IAW EA 103328.SDR DALA1152125808Skin · damagedER/A 485729-14 ISSUED FOR FUSELAGE SKIN REPAIR AT BS 780+80, BETWEEN S-5L AND S-7L. FOLLOW ON ACTION IS REQUIRED ACCOMPLISH SECTION II INSPECTION NO LATER THAN 34300 TOTAL A/C FLIGHT CYCLES. SECTION II IS PENDING A STAGE III DTA. CONTACT ENGINEERING WHEN THSDR UHLA2011090200288Doubler · corrodedLEVEL 2 CORROSION WASTE SERVICE PANEL AFT INTERNAL SUPPORT. REMOVED AND INSTALLED NEW DOUBLER ON AFT SIDE OF WASTE SERVICE PANEL IAW EMB SRM 51-40-02 AND 51-43-02.SDR USAA2011090700002Skin · crackedSKIN PANEL - .25 INCH CRACK INDICATION BOTTOM RIVET ROW SECOND LAYER SKIN LAP JOINT AT BS 817, S4R. REPAIRED FUSELAGE SKIN AT BS 817, S4R IAW B737 SRM 53-00-01, REPAIR 31.SDR AALA20110902TUL01Skin · dentedDENT AT STATION 675 BETWEEN STRINGERS 23 AND 24 LEFT. ACCOMPLISHED DOUBLER REPAIR PER SRM 53-00-01-2R-3.SDR SWAA116324Skin · crackedDURING SCHEDULED MV2 CHECK, FOUND SKIN CRACKED AT BS 465+6, STR 26L. REPAIRED SKIN PER SRM.SDR SWAA116298Skin · crackedDURING SCHEDULED 26Y CHECK, FOUND SKIN CRACKED AT BS 500A+3, STR 16L. REPAIRED SKIN PER EA.SDR FDEA201109023636Skin · damagedFWD CARGO DOOR CUTOUT AT FR 20 APPROX 30" UP FROM SILL BEAM THERE IS A FIELD BLEND THAT MEASURES APPROX 1.5 IN L X .500 W X .100 IN D. REPAIRED IAW SRM 53-13-13, FIG 201-210.SDR FDEA201109013612Skin · damagedLEFT FUSELAGE SKIN AT FR 13, LOCATION 14TH, FASTENER UP FROM STR 25 LOCATION HAS A SKIN MARK TO THE SIDE OF THE HOLE REWORK OUT OF SRM LIMITS. BLENDED AND ASSESSED IAW SRM 53-12-12. INSPECTED IAW NTM 51-10-01/51-40-00/51-35-05 NO DEFECTS. AREA BLENDED 1" SDR FDEA201109013603Skin · gougedEXTERIOR FUSELAGE, 2 LONG GOUGES UNDER L-1 DOOR. CUTOUT DAMAGE AREA IAW SRM 53-30-3 REV 103 FIG 1. FABRICATED REPAIR DOUBLER AND FILLER IAW SRM 53-30-3 FIG 1. INSTALLED REPAIR FILLER AND DOUBLER IAW SRM 51-30-2 AND 53-30-3 FIG 1.SDR SWAA116469Skin · crackedDURING SCHEDULED CV CHECK, FOUND SKIN CRACKED AT BS 749, STR 24L. REPAIRED SKIN PER SRM.SDR DALA1150839013Skin · dentedDURING HMV DENTS AND SCRATCHES WERE FOUND ON FUSELAGE SKIN REPAIR DOUBLER STA Y=236 BETWEEN LONG 18LT AND 17LT (TO 220111).SDR JR2R2011090100361Skin · damagedELONGATED HOLE FOUND AFTER SCREW SHANK REMOVAL FR BELOW DORSAL STRKE AT FS 1142.1 AND 1139.4 AT RBL 1.00.SDR FDEA201109013629Skin · damagedRIGHT FUSELAGE HAS 4" CREASE DENT AT FR 38.2-42R WITH FASTENER PULLING AND DISHED, DUE TO PREVIOUSLY MISLOCATION OF CRADLE AT FR. 38.2 VERSES FR 39 - REF EA 6-5310-145629, PG 4 AND EO 6-5310-7-5001, PT 2 COMPLIED WITH EVALUATION OF RT FUSELAGE 4" CREASE DENTSDR FDEA201109013628Skin · damagedLEFT FUSELAGE HAS 4" CREASE DENT AT FR 38.2, STR 42L WITH FASTENER PULLING AND DISHED DUE TO PREVIOUSLY MIS-LOCATION OF CRADLE AT FR 38.2 VERSUS FR 39 - REF EA6-5310- 145629, PG 4 AND EO 6-5310-7-5001, PT2. COMPLIED WITH EVALUATION OF LT FUSELAGE 4" CREASE DSDR FDEA201109013614Doubler · corrodedRADIO ALTIMETER ANTENNA FUSELAGE MATING SURFACE, 4 LOCATIONS FOUND CORRODED. DOUBLERS REMOVED IAW SRM 51-31-01, REV 47. NEW DOUBLERS INSTALLED IAW SRM 51-31-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 113.SDR DALA1400260960Skin · gougedFUSELAGE SKIN BS 1300-1308, L20-21L, REPAIRED GOUGES IAW ERA 495783-14.SDR AALA20110906AFW06Skin · corrodedHEAVY CORROSION ON THE FUSELAGE SKIN INNER SURFACE BETWEEN STATIONS 1082 TO 1087 STRINGERS 38 LEFT AND 38 RIGHT BETWEEN KEEL BEAM CHORDS. REMOVED DAMAGE IAW B767 SRM 53-00-01, PERFORMED DVI WITHIN 22 INCHES OF THE REPAIR TO ENSURE DAMAGE FREE CONDITION. PERFSDR SWAA116270Skin · crackedDURING SCHEDULED SPV CHECK, FOUND FUSELAGE SKIN CRACKED BETWEEN BS 360 TO BS 540. REMOVED AND REPLACED SKIN IAW SRM.SDR SWAA116269Skin · crackedDURING SCHEDULED SPV CHECK, FOUND FUSELAGE WINDOW SKIN CRACKED AT BS 500B+10 UPPER CORNER. REMOVED AND REPLACED SKIN IAW SRM.SDR SWAA116266Skin · crackedDURING SCHEDULED 20Y CHECK, FOUND SKIN CRACKED AT BS 727C+8, STR 23L. REPAIRED SKIN IAW SRM.SDR SWAA116262Skin · crackedDURING SCHEDULED 22Y CHECK, FOUND SKIN CRACKED AT BS 273, STR 16L. REPAIRED SKIN IAW SRM.SDR SWAA116260Skin · crackedDURING SCHEDULED SPV CHECK, FOUND FUSELAGE WINDOW SKIN CRACKED AT BS 440+10, UPPER FORWARD CORNER CUTOUT. REPAIRED SKIN IAW EA.SDR SWAA116259Skin · crackedDURING SCHEDULED SPV CHECK, FOUND FUSELAGE WINDOW SKIN CRACKED AT BS 400+10, UPPER FORWARD CORNER CUTOUT. REPAIRED SKIN IAW EA.SDR DALA1151669885Skin · dentedDENT ON FUSELAGE SKIN AT STA 222, 3" BELOW CUSP LINE L18L. COMPLIED WITH ER/A 495312-14 REV ORIG SECTION 1 ACCOMPLISH CLOSE VISUAL INSP OF REPAIR AREA FOR LOOSE MISSING FASTENERS, REF SECTION 2 ER/A 495312-14 REV ORIGINAL ACCOMPLISH SECTION 2 PRIOR TO 3000 FLSDR QXEA2011090600802Panel · corrodedPANEL 262HT FWD MATING SURFACE HAS FRETTING. BLENDED DAMAGE AREAS IAW RD 8/4-53-521. MINIMUM REMAINING THICKNESS .098" FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLETED REPAIRS IAW RD 8/4-53-521.SDR QXEA2011090600801Panel · corrodedPANEL 261LT FORE AND AFT MATING SURFACE HAS FRETTING. BLENDED DAMAGE AREAS IAW RD 8/4-53-521. MINIMUM REMAINING THICKNESS .093" FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLETED REPAIRS IAW RD 8/4-53-521.SDR QXEA2011090600800Skin · corrodedPANEL 261HT AFT MATING SURFACE HAS FRETTING. BLENDED DAMAGE AREAS IAW RD 8/4-53-521. FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLETED REPAIRS IAW RD 8/4-53-521.SDR QXEA2011090600799Skin · damagedPANEL 262FT FORE MATING SURFACE HAS FRETTING. BLENDED DAMAGE AREAS IAW RD 8/4-53-521. FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLETED REPAIRS IAW RD 8/4-53-521.SDR QXEA2011090200789Skin · damagedPANEL 261FT FWD MATING SURFACE HAS FRETTING. BLENDED DAMAGED AREAS IAW RD 8/4-53-521, FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLIED WITH REPAIR IAW GENERIC PERMANENT REPAIR IAW RD 8/4-53-521.SDR QXEA2011090200788Panel · damagedPANEL 261CT FWD MATING SURFACE HAS FRETTING. BLENDED DAMAGED AREAS IAW RD 8/4-53-521, FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLIED WITH REPAIR IAW GENERIC PERMANENT REPAIR IAW RD 8/4-53-521.SDR QXEA2011090200787Panel · damagedPANEL 262AT FWD MATING SURFACE HAS FRETTING. BLENDED DAMAGED AREAS IAW RD 8/4-53-521, FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLIED WITH REPAIR IAW GENERIC PERMANENT REPAIR RD 8/4-53-521.SDR QXEA2011090200786Panel · damagedPANEL 262HT FWD MATING SURFACE HAS FRETTING. BLENDED DAMAGED AREAS IAW RD 8/4-53-521, FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLIED WITH REPAIR IAW GENERIC PERMANENT REPAIR RD 8/4-53-521.SDR QXEA2011090200785Panel · corrodedPANEL 262FT FORE MATING SURFACE HAS FRETTING. BLENDED DAMAGED AREAS IAW RD 8/4-53-521, FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLIED WITH REPAIR IAW RD 8/4-53-521.SDR QXEA2011090200784Panel · corrodedPANEL 261LT FORE AND AFT MATING SURFACE HAS FRETTING. REMOVED FRETTING DAMAGE IAW RD 8/4-53-521. COMPLIED WITH RD 8/4-53-521.SDR QXEA2011090200783Panel · corrodedPANEL 261HT AFT MATING SURFACE HAS FRETTING. BLENDED DAMAGE FROM PANEL REF RD 8/4-53-521 AND FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLIED WITH GENERIC PERMANENT REPAIR FOR CHAFING PANEL IAW RD 8/4-53-521.SDR AALA20110830TUL11Skin · corrodedCORROSION BETWEEN AFT LAV SERVICE PANEL PAN AND SKIN LOWER FORWARD CORNER. ACCOMPLISHED DOUBLER REPAIR INSTALLED PER EA MD80-53-018910 DATED 08/30/11.
Back to JASC 5330