JASC 5340
Service difficulty reports · 22,389
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR QXEA2025111400342Clamp · deterioratedON PRE FLIGHT WALKAROUND, CREW REPORTS HYD LINES SUPPORT BLOCK CLAMP IS DETERIORATED. (LH WHEEL WELL). REMOVED FROM SERVICE. INSPECTED BLOCK CLAMP, (P/N # 170-09131-901, IPC REF 29-10-15-41, ITEM 300) FOUND TO BE SATURATED WITH FUEL. FOUND FUEL SEEP. REF TANK SDR DALA2025111108241Bracket · damagedTOOLING DAMAGE ON BRACKET AFT SIDE OF FRAME 62 JUST INBOARD OF S2. REPLACED THE BRACKET IAW SRM 53-11 AND DRAWING F5349104243. (1297739)SDR SWAA2025120333182Attach Angle · corrodedAFT CARGO BAY FRAME TO SIDEWALL SUPPORT ATTACH ANGLE HAS CORROSION ON UPPER FLANGE AT FASTENER HOLES, BS 727D, S19L - S25L. REMOVED AND REPLACED AFT CARGO BAY FRAME TO SIDEWALL SUPPORT ATTACH ANGLE IAW SRM 51-40-02, & DWG 146A12290073 REV -.SDR SWIA2026031875540Stringer Clip · corrodedSTRINGER CLIP 22L JUST AFT OF FRAME 559+112 CORRODED. R & R STRINGER CLIP IAW DWG 601R31057, REV J, SRM 51-42-06, & 51-42-21.SDR VNAA202601170005Support · corrodedCORROSION ON MLG HYDRAULIC LINES SUPPORT PLATES (IN BK, LG EXT, LG RET) AND ON CONNECTORS SUPPORT PLATE (PX33, PX17, PX34, PX19) AT RH/LH WHEEL WELL AREA. MLG HYDRAULIC LINES SUPPORT PLATES (IN BK, LG EXT, LG RET) AND ON CONNECTORS SUPPORT PLATE (PX33, PX17,SDR SWAA2025111132874Attach Bracket · damagedLEFT WING UPPER OTBD MLG SUPPORT BEAM ATTACH BRACKET HAD ELONGATED HOLES. REMOVED AND REPLACED SUPPORT BRACKET PER SRM 51-40-02.SDR AALA202512053887Attach Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: LEFT HAND MAIN LANDING GEAR DOOR FORWARD ACTUATOR ATTACH FITTING HAS CRACKED / ELONGATED HOLES. REPLACED FITTING PER CMM 52-81-18.SDR AALA202511101777Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: KEEL BEAM ATTATCHMENT L/H AFT TITANIUM ANGLE IS CRACKED THRU LOWER FASTENER. MAINTENANCE REPLACED L/H AFT TITANIUM ANGLE PER STEP 3 E OF CARD 26T14053002.SDR 2A6R2025110374702Attach Angle · corrodedCORROSION DAMAGE WAS DISCOVERED ON THE LOWER LH, RH & AFT BROOM CLOSET ATTACHMENT ANGLES (L533M1052317 (X2) & L533M1052318). A DETAILED DESCRIPTION OF THE DAMAGE AND AN APPROVED FABRICATED PROCEDURE IS PROVIDED IN EA 23-5300-EA-5341; INITIAL REVISION DATED 13 SDR SWIA2025120101102Attach Angle · corrodedCORROSION FOUND ON ATTACH FLANGE OF STR22L FS280-FS333 (C-CHECK RO 11/30/2025)REPLACED STRINGER FROM STR22L FS280-FS333 REF. DWG#SH670-31630 REV K, CRJ700 SRM 51-42-06-001-001-A01; 51-42-21-001-001-A01. COMPLIED WITH TASK CARD 51-900-1002-SKY. ALL CHECKS GOOSDR AALA202511039391Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN CENTER SECTION REAR SPAR VAPOR BARRIER UPPER ATTACH ANGLE, LOCATED IN RIGHT ECS BAY, AT BS 663, RBL 20. REPLACED THE ATTACH ANGLE IAW SRM 57-10-10-2R-5.SDR SWAA2025112030268Attach Bracket · crackedSEAT TRACK NR 1 ATTACH BRACKET CRACKED ON BOTH INBD & OTBD RADII AT BS 727B UNDER FLOORBOARD 241FF. HFEC VERIFIED THE ATTACHED BRACKET IS CRACKED AT BOTH LOCATIONS IAW NDT PART 6; 51-00-00, PROCEDURE 23. REMOVED DAMAGED SPLICE STRAP BRACKET AT BS 727B, LBLSDR SWAA2025111130181Attach Angle · crackedBS 663 RT VAPOR BARRIER UPPER ATTACH ANGLE AT RBL 13 COMMON TO FUEL TANK SHOWS A CRACK INDICATION.SDR JR2R20251030435Attach Fitting · chafedRH MAIN WHEEL WELL FWD O/B BULKHEAD AILERON QUADRANT ATTACH FITTING CRACKED. REPLACEDSDR 2A6R2025103074501Attach Angle · corrodedDURING INSPECTION, CORROSION DAMAGE WAS DISCOVERED ON THE LOWER LH, RH & AFT BROOM CLOSET ATTACHMENT ANGLES (L533M1052317 (X2) & L533M1052318). A DETAILED DESCRIPTION OF THE DAMAGE AND AN APPROVED FABRICATED PROCEDURE IS PROVIDED IN AIR METHODS ENGINEERING AUSDR SWAA2025112029386Attach Angle · crackedCRACK FOUND ON BS 663 LT ATTACH ANGLE, LBL 34. REMOVED TANK FASTENERS FROM LBL 34 TO LBL 65. CUT AND REMOVED DAMAGED SECTION OF ATTACH ANGLE IAW SRM 57-10-10-2R-5. CW NDT INSPECTIONS OF HOLES COMMON TO REPAIR IAW PART 6 51-00-00. PROCEDURE 16, AND PERFORMSDR SWAA2025112029387Attach Angle · crackedCRACK FOUND ON BS 663 RT ATTACH ANGLE, RBL 34. REMOVED DAMAGED SECTION OF RT STA 663 ATTACH ANGLE FROM APPROX RBL 24 TO RBL 65. COMPLIED WITH STEP 2, COMPLIED WITH REMAINING FASTENER HOLE INSPECTION AT REPAIR HOLES IAW NDT PART 6 51-00-00, PROCEDURE 16. NO SDR SWAA2025111729432Attach Angle · crackedB.S. 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE IS CRACKED AT LBL 45, WL 167. REMOVED, REPLACED, AND INSTALLED A NEW 663 LT UPPER ATTACH ANGLE LBL 4- TO LBL 65 IAW SRM 51-40-02-0G-0, AND DWG 111A1000, REV -.SDR SWAA2025111729691Attach Angle · crackedCRACKED ATTACH ANGLE AT MID CABIN BS 690, RBL 1, WL 206. REMOVED FABRICATED AND REPLACED ATTACH ANGLE AT PASSENGER COMPARTMENT BS 690, RBL 1, WL 206 IAW SRM 51-10-02-0G-0, SRM 51-40-02-0G-0 AND DWGS 273A9112, REV H, 273A9112, REV-, 273A9110, REV A.SDR AALA202510296999Attach Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FLIGHT DECK WINDSHIELD FRAME SIDE POST UPPER ATTACHMENT FITTING FASTENER HOLE, AT FR 4 RIGHT. REPLACED FITTING PER SRM 51-72-11.SDR IXXA20251026002Beam · crackedSTUB BEAM REQUIRES REPAIR AT INNER CORD STA 883.5, RBL89, WL200SDR SWAA2025111328441Nut Plate · debondedAFT CARGO LEFT FLOOR TRANSITION ANGLE FROM BS 727I TO 787, DISBONDED NUTPLATES (QTY.10).<[01] INSTALLED BONDED NUTPLATES (QTY.10) ON AFT CARGO L/H FLOOR TRANSITION ANGLE FROM STA 727I TO STA 787 PER SRM 51-41-10.SDR SWAA2025112027218Attach Bracket · crackedSEAT TRACK NR 4 ATTACH BRACKET CRACKED ON BOTH INBD AND OTBD RADIUS'S AT BS 727B, UNDER FLOORBOARD 242DF. VERIFIED CRACKS IAW NDT MANUAL, PART 6, 51-00-00, PROC.23. REMOVED FASTENERS AND DISPLACED CRACKED GUSSET IAW SRM 51-40-02. REMOVED GUSSET, LOCATED, ASDR SWAA2025112027219Attach Bracket · crackedSEAT TRACK NR 1 ATTACH BRACKET CRACKED ON BOTH INBD & OTBD. RADIUS'S AT BS 727B UNDER FLOORBOARD 241FF. VERIFIED CRACKS PER 737 NDT MANUAL PART 6; 51-00-00 PROC.23. REMOVED CRACKED GUSSET PER SRM 51-40-02. LOCATED AND DRILLED NEW GUSSET PER SRM 51-40-02.SDR SWAA2025111327424Attach Angle · crackedRIGHT VAPOR BARRIER ATTACH ANGLE BS 663 CRACKED AT FASTENER RBL 31. REMOVED DAMAGED SECTION OF RH STA 663 VAPOR BARRIER ATTACH ANGLE FROM RBL 31 TO RBL 65 PER SRM 57-10-10-2R-5;[02] RII. VERIFIED. REMOVED DAMAGED SECTION OF RH STA 663 VAPOR BARRIER ATTACH ANGSDR AALA202510284059Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER UPPER ATTACH ANGLE, LOCATED IN LEFT ECS BAY, AT STA 663, LBL 20. REPLACED ANGLE PER SRM 57-10-10-2R-5.SDR DALA2025102407778Bracket · brokenOXYGEN BOTTLE BRACKET BROKEN. CORRECTIVE ACTION: FOUND LATCHES LOOSE. TIGHTENED AND RESECURED LATCHES AND BOTTLES AS REQUIRED PER A319 AMM 35-21. (1268132)SDR SWAA2025120126957Attach Angle · crackedBS 663, LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE IS CRACKED AT LBL 45, WL 165. REMOVED, REPLACED, AND INSTALLED A NEW ATTACH ANGLE IAW SRM 51-40-02-0G-0, AND DWG 111A1000, REV A.SDR SWAA2025120127298Attach Angle · corrodedCORROSION AFT CARGO BAY ATTACH ANGLE UNDER SHIELD HAS MULTIPLE AREAS UNDER NUT PLATES BS 767 TO 787, RBL 21, WL 156. CORROSION ON AFT CARGO BAY ATTACH ANGLE UNDER SHIELD FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM. REMOVED, REPLACED, ANDSDR HNAA2025112400788Attach Fitting · crackedLEFT WING TO BODY FAIRING, FUSELAGE ATTACHMENT FOUND CRACKED AT FR48. REPAIRED IAW SRM 53-23-12SDR SWAA2025112027210Attach Angle · crackedBS 663 RT VAPOR BARRIER UPPER ATTACH ANGLE CRACKED AT RBL 34. REMOVED FASTENERS IN THE ATTACH ANGLE AND BULKHEAD IAW SRM 51-40-02. MATCH DRILLED NEW REPLACEMENT ANGLE IAW SRM 51-40-02. INSTALLED FASTENERS IN ATTACH ANGLE IAW SRM 51-40-02 & DWG 111A1000. SDR SWAA2025112027211Attach Angle · crackedBS 663 LT VAPOR BARRIER UPPER ATTACH ANGLE CRACKED AT LBL 34. REMOVED THE LT VAPOR BARRIER UPPER ATTACH ANGLE IAW SRM 51-40-02. C/W HFEC OF OPEN HOLES IN REPAIR AREA PER NDT PART 6 51-00-00 PROD. 16, NO DEFECTS NOTED. MATCH DRILLED NEW ANGLE IAW SRM 51-4SDR IPXA2025112675242Nut Plate · corrodedBULK CARGO CEILING AREA AT STA. 1681 HAS 3EA CORRODED NUTPLATES (FWD AND AFT SIDES OF FLOOR BEAM). 83-011 ATA 53-10. INSTALLED NUTPLATE ASSY 3EA P/N146N5693-5 PER DWG 146N5693/SAMPLE PARTS, IAW B757-200PF SRM 51-40-02-OG-0.SDR IPXA2025111975189Nut Plate · corrodedBULK CARGO CEILING AREA AT STA. 1720 HAS 8EA NUTPLATES WITH CORROSION . INSTALLED NUTPLATE ASSY AT BULK CARGO CEILING AREA AT STA. 1720 PER DWG 146N5693 IAW B757-200PF SRM 51-40-02-OG-0.SDR IPXA2025110575242Nut Plate · corrodedBULK CARGO CEILING AREA AT BS 1681 HAS 3EA CORRODED NUTPLATES (FWD AND AFT SIDES OF FLOOR BEAM). 83-011 ATA 53-10 REVIEWEDSDR AALA202510240190Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK ON CONNECTING FITTING ON MLG AREA LH SIDE L=0.163 INCH. MAINTENANCE ACCOMPLISHED PERMANET REPAIR INSTRUCTION (REPLACED CONNECTING PLATE) LOC BTW FR42 TO FR43 AT LEVEL OF WEB W10 AT MLG AREA ON LH SIDE IAW EA 368107, A320 SRMSDR AALA202510230911Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE AT STA 663, LBL 40. REPLACED ANGLE PER AARD 51-00-05-1.SDR DALA2025102007666Bracket · damagedTOOLING DAMAGE ON BRACKET AT FASTENERS FWD SIDE OF FRAME 26.1 @ P'4. REPAIRED PER ERA 628177-14 REV ORIG. (1260106)SDR DALA2025102007662Fitting · damagedRING ATTACHMENT FASTENER HOLES AT BTW FR53.7-FR53.8 AND STR 2R - STR4R IMPROPER. CORRECTED PER ERA 620877-14 REV.B. (1259633)SDR AALA202510201286Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE AT STA 663, FROM RBL 5 TO RBL 15. (RIGHT HAND INBOARD ECS BAY.) REPAIRED ANGLE PER SRM 57-10-10-2R-5.SDR SWAA2025110625349Attach Angle · crackedCRACK FOUND AT BS 663 VAPOR BARRIER ATTACH ANGLE APPROXIMATELY LBL 9. REPAIRED THE UPPER ATTACH ANGLE IAW SRM 57-10-10-2R-5.SDR SWAA2025110625350Attach Angle · crackedCRACK FOUND AT BS 663 VAPOR BARRIER ATTACH ANGLE APPROXIMATELY RBL 9. REPAIRED THE UPPER ATTACH ANGLE IAW SRM 57-10-10-2R-5.SDR VNAA20251015049Attach Angle · corrodedDISCREPANCY: INTERCOSTAL ATTACH ANGLES AT F.S 517-533 STR 26L ARE CORRODED AND HAVE OVERSIZE HOLES CORRECTIVE ACTION: INSTALLED NEW PN: SH670-33399-951 AND PN: SH670-33600-983 BETWEEN FS 517 - FS 533, STR 27 - STR 26L (LBL 2.6) IAW CRJ-700 SRM 51-42-06-001-001SDR 2025FA0000712Bracket · brokenFUEL FLOW TRANSDUCER BRACKET HAS DEVELOPED MAJOR CRACK ON THE BOTTOM SIDE OF THE BRACKET.SDR 2025FA0000711Attach Bracket · brokenFUEL FLOW TRANSDUCER BRACKET HAS DEVELOPED MAJOR CRACK ON THE BOTTOM SIDE OF THE BRACKET.SDR CALA2025101510122Bracket · crackedAFT BULK CARGO, WATER SERVICE BOX HAS A BRACKET WITH A CRACK, NEAR BS 1681.8, S30. REMOVED AND REPLACED AFT BULKHEAD BRACKET NEAR BS 1581.8 S30 IAW SRM 51-10-02.SDR CALA2025101410064Stringer Clip · crackedAFT CARGO COMP, BS 1380, NEAR S-27R, FLOOR STR CLIP HAS A CRACK. DOT 23-065 COMPLETED SFR REPORTING ONLY REMOVED AND REPLACED STR CLIP AT OFF CARGO COMP. STA 1380 FLOOR STR 5-27R IAW B757-200 SRM 51-40-02, DWG. 146N5393 AND TRAVELER T25/1835297.SDR AALA202510135889Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE LOCATED AT BS 663.5, RBL 33. REPAIRED PER SRM 57-10-10-2R-5.SDR SWI2026F00027Cleat · gougedFRAME TO LONGERON CLEAT AT WL73.00, RH FS484.00 IS GOUGED ON AFT SIDE AT FLOOR (C-CHECK RO 01/03/2026)BLENDED GOUGED AREA ON FRAME TO LONGERON CLEAT AT WL73.00 RH FS 484.00 REF REO 601R-53-41-3366 REV -- DATED 2025-11-04 STEPS 1 THROUGH 4. ORIGINAL THICKNESS SDR SWIA2026010509Cleat · gougedFRAME TO LONGERON CLEAT AT WL73.00, LH FS461.50 IS GOUGED ON UPPER FORWARD SIDE. REMOVED AND REPLACED BY NEW FRAME TO LONGERON CLEAT AT WL73.00, LT FS461.50 REF. DWG 601R31145 REV. -P, DWG 601R31034 REV. -F AND SRM 51-42-21, REV. 39, PERFORMED LEAK CHECK G
Back to JASC 5340