duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2013071600017Cleat · corroded2S CHECK - CORROSION ON CLEAT AT FR 32 AND BETWEEN S42-43R. REPLACED CLEAT IAW SRM 51-72-11 AND DWG D53234615.SDR USAA2013071600016Cleat · corroded2S CHECK - CORROSION ON CLEAT AT FR 34 & BETWEEN S41-42R. REPLACED CLEAT IAW A321 SRM 51-72-11 AND DWG D532305142002.SDR SWAA2013070817975Stringer Clip · corrodedSTRINGER CLIP CORRODED AT STATION 794, STRINGER 26R. R&R CLIP IAW SRM & DRAWING.SDR SWAA2013062517577Stringer Clip · crackedAFT SIDE OF FRAME STRINGER CLIP CRACKED AT BS 947, STRINGER 25R. R&R STRINGER CLIP IAW SRM & DRAWING.SDR UALA2013062104324Bracket · brokenCREW REPORTED FIRE EXTINGUISHER BEHIND 6B MISSING. FOUND BRACKET BROKEN.SDR DALA13029963216Cleat · corrodedDURING INSPECTION, FOUND CORROSION ON CLEAT IN FWD CARGO COMPARTMENT LOCATED BETWEEN STGR 43L AND STGR 44 AT FR 32. REPLACED CLEAT IAW 51-72-11.SDR DALA13030123216Cleat · corrodedDURING INSPECTION, FOUND CORROSION ON CLEAT IN FWD CARGO BAY BETWEEN STRINGER 43 - 44L FR 32. REPLACED CLEAT AND FASTENER FWD CARGO COMPARTMENT IAW SRM 51-72-11 AND DWG D53231212.SDR IPXA13579133Attach Angle · corrodedINSPECTION TYPE:C8 AFT CARGO LT SIDE LOWER WEB ATTACH ANGLE BELOW TRANSITION PANEL CORRODED BS 1490 S27L. REMOVED, FABRICATED & INSTALLED NEW ANGLE IAW DWG.SDR IPXA3579039Attach Angle · corrodedINSPECTION TYPE:C-8, AFT CARGO LT SIDE LOWER WEB ATTACH ANGLE BELOW TRANSITION PANEL IS CORRODED. FABRICATED A NEW ATTACH ANGLE IAW DWG 146N5434-15.SDR DALA13029953216Cleat · corrodedDURING INSPECTION FOUND CORROSION ON CLEAT LOCATED BETWEEN STR 41R AND STR 42R AT LEVEL FR 31 FWD CARGO COMP. L=0.50", W=0.20", D=0.001" APROX. REPLACED CLEAT LOCATED BETWEEN STR 41R AND STR 42R AT LEVEL FR 31 FWD CARGO COMPARTMENT, IAW SRM 51-72-11 AND DWG DSDR DALA13029943216Cleat · corrodedDURING INSPECTION, FOUND CORROSION ON CLEAT LOCATED AT FR 32 BETWEEN STGR 40L AND STGR 41LIN FWD CARGO COMPARTMENT L=0.800", W=0.500", D=0.001" APPROX. REPLACED CLEAT LOCATED FR 32 BETWEEN STR 40L AND STR 41L IN FWD CARGO COMPARTMENT, IAW SRM 51-72-11 AND DWGSDR REXA2013061701192Mount · crackedCRASH AXE HOLDER THAT MOUNTS TO COCKPIT PANEL 222LRW IS CRACKED. R & R WITH SERVICEABLE CRASH AXE HOLDER IAW SRM 51-41-02.SDR SWAA2013061917390Stringer Clip · crackedSTRINGER CLIP CRACKED AT STA 727B, STR 8R. R & R CLIP IAW BAC DWG & SRM.SDR R61A201306140541Bracket · brokenCREW REPORTED THE AFT MEGAPHONE BRACKET BROKEN. MX SECURED MEGAPHONE TO MOUNT IAW AMM AND OPS CHECKED GOOD.SDR DALA13029133216Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CENTER FITTING LOCATED BETWEEN FR 16 AND FR 20 AT LEVEL STR 23 RT L=0.500" W=0.250" D=0.001" APPROX. REPLACED CENTER FITTING IAW SRM 51-72-11 AND DWG D53112198.SDR DALA13029493216Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CORNER FITTING AND FASTENERS LOCATED FR 68 AT STR 23. REPLACED CORNER FITTING AND FASTENERS IAW SRM 51-72-11 AND DWG NR D53480019.SDR 39NR20130612005Mount · corrodedDURING PHASE 48 INSPECTION FOUND CORROSION IN LAV E AFT OTBD MOUNT FITTING. REPLACED MOUNT FITTING IAW SPM 25-46-99.SDR 39NR20130612004Mount · corrodedDURING PHASE 48 INSPECTION FOUND CORROSION IN LAV A AFT INBD MOUNT FITTING. REPLACED MOUNT FITTING IAW SPM 25-46-99.SDR 39NR20130612003Mount · corrodedDURING PHASE 48 INSPECTION FOUND CORROSION IN LAV A FWD OUTBD MOUNT FITTING. REPLACED MOUNT FITTING IAW SPM 25-46-99.SDR 39NR201306120001Mount · corrodedDURING PHASE 48 INSPECTION FOUND CORROSION IN LAV D INBD FWD MOUNT FITTING. REPLACED MOUNT FITTING.SDR ASOA2013062103881Attach Angle · corrodedATTACH ANGLE BS 349, RT OTBD CORRODED. R & R ATTACH ANGLE IAW SRM 51-42-06 AND SRM 51-42-21.SDR SWAA2013061917341Attach Angle · corrodedAFT CARGO COMPARTMENT LOWER ATTACH ANGLE FOR THE AFT BULKHEAD PANEL CORRODED AT BS 947, BETWEEN LBL 15 TO RBL 15. R & R ANGLE IAW SRM.SDR DALA13027913216Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CENTER FITTING LOCATED BETWEEN FR 66 AND FR 68 AT LEVEL STR 23 LT L=0.500", W=0.250", D=0.001" APPROX. REPLACED CENTER FITTING LOCATED BETWEEN FR 66 TO FR 68 AT LEVEL STR 23 LT IAW SRM 51-72-11 AND DWG D53480020.SDR DALA13027903216Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CENTER FITTING LOCATED BETWEEN FR 66 AND FR 68 AT LEVEL STR 23 RT L=0.500" W=0.250" D=0.001" APROX SSI 534132. REPLACED CENTER FITTING LOCATED BETWEEN FR 66 AND FR 68 AT LEVEL STR 23 RT IAW SRM 51-72-11 AND DWG D53480020.SDR ASOA2013062708516Attach Angle · corrodedRT LOWER FS 280 DOOR POST AND ATTACH ANGLE CORRODED. REPAIRED IAW SRM 51-42-13-001-001-A01, 51-42-06-001-001-A01, 51-42-13-001, 51-21-11-00 & REO 670-53-11-839. REPAIR CLASSIFIED AS MAJOR.SDR ASOA2013062708515Attach Angle · corrodedLT LOWER FS 280 DOOR POST AND ATTACH ANGLE CORRODED. REPAIRED IAW SRM 51-21-06-001-001-A01, 51-42-13-001-001-A01, 51-42-13-001, 51-42-13-001-001-A01, 51-42-06-001-001-A01 & REO 670-53-11-839. REPAIR CLASSIFIED AS MAJOR.SDR DALA13027640975Attach Bracket · wornMX DISCOVERED THAT BOTH OF THE TAILCONE ATTACH BRACKETS ARE WORN FROM THE SPRING. THE BRACKETS WERE REPLACED AND THE SYSTEM WAS RIGGED TO SPECIFICATIONS. THE RII STEPS WERE COMPLETED AND THE FUNCTIONAL CHECK WAS COMPLETED SATISFACTORILY.SDR WWQA20130606001Fitting · crackedCREW REPORT THE MAIN ENTRY DOOR WAS NOT CLOSING COMPLETELY. MX FOUND DURING TROUBLESHOOTING THE PROBLEM A CRACK IN A FITTING AFT OF FRAME 169 WHERE THE MAIN ENTRY DOOR ACTUATOR ATTACHES.SDR ASOA2013070908582Mount · corrodedRT GALLEY FITTING AT RBL 21 FLOOR SUPPORT BETWEEN FS 280 - 295 HAS DEEP CORROSION. R & R GALLEY FITTING IAW SRM 51-42-21-001-001.SDR K11A2013070925007Stringer Clip · corrodedSTRINGER TO FRAME ATTACH CLIP CORRODED STA 900, STR 27L.SDR ASAA2013060595206Stringer Clip · crackedSTINGER CLIP AT BS 500E, STR 7R IS CRACKED AT FASTENER HOLE. ACFT GROUNDED. REMOVED DAMAGED STRINGER CLIP. LOCATED AND DRILLED AND INSTALLED NEW STRINGER CLIP IAW SRM 51-40-05, FIG 3.SDR A6WA201306181014Mount Bracket · crackedAEB RT NR 2 HYD RETURN MANIFOLD FWD ATTACH BOLT IS PULLING THRU THE HYD RACK MOUNTING BRACKET, BRACKET IS CRACKED. R & R BRACKET.SDR SWAA2013061917416Attach Angle · corrodedBULKHEAD LOWER ATTACH ANGLE CORRODED AT BS 947, STR 23R. R & R ANGLE IAW SRM.SDR ASOA2013071708705Mount · corrodedGALLEY FWD INBD AND AFT INBD FLOOR STRUCTURE MOUNT PLATES AT FS 295 AND 315 RBL 5 CORRODED AND FWD OTBD MOUNT PLATE AT FS 285 RBL 36 CORRODED. REPAIRED IAW EO 601R38669 AND 51-42-06 & 51-42-10.SDR CALA2013060300384Attach Angle · corrodedFWD CARGO COMPARTMENT AFT BULKHEAD CENTER WALL LOWER ATTACH ANGLE FOR PANEL AT BS 500I, BETWEEN S-26L AND S-26R HAS CORROSION. REMOVED AND INSTALLED NEW ANGLE (RAIL ASSY) PN 143A9485Y35, REF SRM 51-40-02.SDR IPXA13178957Fitting · crackedINSPECTION TYPE:10YR, MAIN CABIN FR 12A RT FITTING IS CRACKED. R & R FR 12A RT FITTING IAW EO A300-5310-23539-D, AP APPENDIX E.SDR A6WA201306181024Bracket · crackedBRAKE PRESSURE TRANSDUCER BRACKET IN RT MLG WW CRACKED. R & R BRACKET.SDR SWAA2013062517519Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 360, STRINGER 8R. R&R CLIP IAW SRM.SDR SWAA2013062517520Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 907, STRINGER 8L. R&R CLIP IAW SRM.SDR SWAA2013061917408Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 727A, STR 4L. R & R CLIP IAW SRM.SDR SWAA2013061917407Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 616, STR 5R. R & R CLIP IAW SRM.SDR SWAA2013061917406Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 578, STR 11L. R & R CLIP IAW SRM.SDR SWAA2013061917405Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 380, STR 8L. R & R CLIP IAW SRM.SDR SWAA2013061017013Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 639, STR 4R. R & R CLIP IAW DWG AND SRM.SDR ASOA2013071208621Attach Angle · crackedFS 621-625 INTERCOSTAL ATTACH ANGLE LOWER AT BL 45, STR 15R, WL 87.5 CRACKED. REMOVED CRACKED ATTACH ANGLE IAW SRM 51-42-21. LOCATED AND DRILLED NEW ATTACH ANGLE IAW SRM 51-40-11 AND 51-40-06 AND INSTALLED IAW SRM 51-42-21.SDR SWAA2013062517518Attach Angle · crackedFWD OF R1 DOOR CUTOUT INTERCOSTAL OUTBOARD ATTACH ANGLE CRACKED AT BS 291, WL 240. R&R ANGLE IAW SRM.SDR SWAA2013061017009Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 294.5, STR 23L. R & R CLIP IAW SRM AND DWG.SDR AALA20130530020Attach Angle · corrodedINLET PLENUM AFT WALL INBD ATTACHMENT ANGLES DISTORTED FROM CORROSION. REPLACED ANGLES IAW DWG 353A2000 AND 3532040, SRM 51-30-01 AND 51-40-02.SDR AALA20130530019Attach Angle · crackedINLET PLENUM INBD WALL UPPER ATTACHMENT ANGLE HAS 4.5" CRACK. REPLACED ANGLE IAW AARD 51-00-01-1.SDR SWAA2013070117792Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 727A, STR 21R. R&R CLIP PER SRM.
Back to JASC 5340